Instructions manual Nitrogen Compact Booster
15/38
Technical data
3
TECHNICAL DATA
3.1
General technical data
Name
Value
Inlet pressure
30 - 200 bar
Compressed driving air
minimum 1 bar to 6 bar maximum
Pressurised air purified and oiled
Calculated operating pressure
(at 6 bar air drive pressure)
192 bar (+ Residual bottle pressure)
Pressure relief
400 bar
Transmission
1 : 32
Piston displacement
11,6 cm
3
Medium supply performance*
280 NL/min
*The feed performance is depending on the air drive pressure and from the inlet pressure.
Max. operating temperature
60 °C
Weight
approx. 7,2 kg
Dimensions (WxDXH)
160x380x345 mm
Noise emission
< legally permissible peaks
Connections
Pressurized air
G 1/4"
Nitrogen inlet
Hose line DN4, length 1 m
for N2-bottles 200 bar
Nitrogen outlet
Bottle connection W 24,32 x 1 1/4"
for N2-bottles 200 bar