LaCie Professional Server
Disk Numbering
Technical Brief: RAID
page 12
In
Fig. 12
and
Fig. 13
,
Disk 1
has been physically removed from its
slot. Disk Management no longer has a
Disk 1
but a
Missing
disk.
The other four disks keep their default number assignments since the
5big Storage Server has not been restarted.
Due to the way in which Windows assigns drive numbers, LaCie
highly recommends troubleshooting and, if necessary, replacing a
Missing
disk before rebooting the 5big Storage Server. (See
9. Re-
pairing RAID Configurations
for further information on replacing or
repairing a failed or missing disk.) If the system restarts before the
Missing
disk is repaired, Windows will reassign numbers to the re-
maining disks based upon their physical order.
continued on the next page>>
Fig. 12
DESIGNED BY NEIL POULTON
POWER
LAN 1
USB
USB
eSATA
eSATA
VGA
LAN 1
USB
USB
LAN 2
0
2 3 4
Fig. 13