INSTALLER’S MANUAL
LSG 600 « CLASSIQUE» : GAS HOBS
Nota :*Cet appareil est réglable à l’aide de vérins sur une plage de 13 mm
N.B.This range can be adjusted by up to13 mm by means of adjustable feet
►
LSG 640 «CLASSIQUE»
4 gas hobs :
- 4 burners of different size and power (see hobs
B
,
C
,
D
tabel
1
, appendix
0
).
- Individually controlled by a (thermocouple) safety
valve.
- Electric ignition.
C
C
D
B
300
61
650
722.5
16
131
416
20.5
136.5
Gaz
108
Plaque a bornes
73.5
De 246 È 259
197
35
600
55
490
55
Pressures and hourly consumption
:
Appliance gas supplying can be switched, please refer to rating plate and marking at the rear of the
appliance (
F/O, T, A, B, C, D
: tab.
3
, appendix
0
).
Directives
Gas appliances : 90/396/CEE
Low Voltage : 73/23/CEE
CEM : 89/336/CEE
TECHNICAL DATA SHEETS, MEASUREMENTS
AND DIMENSIONS
►
Stainless steel casing or enamelled steel .
►
Pressed cooking surface.
Gas connection
:
Tube
∅
15/21, 1/2” gas thread, on male
coupling
Electric connection, on terminal block at the rear of the
appliance
Ft 134a - FR - Rév 00 - Date modif : 11/06/07
6/37