INSTALLER’S MANUAL
Encoders :
But before doing this the module must be disconnected from the terminal strip located on the back
of the unit (see
A
, figure
1
).
To access the encoders, remove the top. (See «To remove top»).
Remove the control knop, by pulling off.
Disconnect the electric cable from the induction hob to the encoder (see
B
, figure
2
).
Unscrew the two screws, (see
C
, figure
3
) securing the encoder to the control panel.
Remove the encoder and replacewith the new one.
Replace the components, in reverse order.
Encoder reference
: 65 225006
SERVICING / REPAIRS
1
A
B
Induction unit :
But before doing this the module must be disconnected from the terminal strip located on the back
of the unit (see
A
, figure
1
).
To access the induction unit, remove the top (See «To remove top»).
Disconnect all the cable for the induction hob to the terminal blocks and the encoders cable (see
A
, figure
1
).
Remove the hob and rest it on a stable surface. Ensure the vitroceramic hob is placed on a clean,
soft surface so that the glass top is not scratched (see figure
4
).
3
C
2
Cluny induction - Ft 151a - GB - Rév 05 - Modifié le : 07/10/2013 12/31