INSTALLER’S MANUAL
INSTALLATION/ POSITIONING
◊
Use of the back in fill panel :
This feature is particularly recommended for built-in ovens as it ensures a 50 mm gap between the
appliance and the wall. It also increases the depth of the hob to 722,5 mm.
Product code : DS 1400.
Back in fill panel
A shut-off valve must be install and accessible close to the appliance in order to isolate it from the
gas applicable or to facilitate cutting the gas supply
:
Please ensure that installation complies with
local applicable regulations and standards
-
Natural gas supply :
Mandatory to install an Automatic Shut-off Valve (since 1st July 1997 in France)
-
LPG supply (butane, propane) :
Propane : Class 1 Safety Expansion Valve.
Butane :
Butane safety expansion valve fitted to the cylinder (connected to the range by a LPG
approved hose, maximum length 2 metres).
We recommend the front edge of the hob be positioned 50 mm further forward than the adjacent
fittings
.
(see below).
If the adjacent parts contain heat-sensitive materials, ensure there is a 50-mm gap between the
side of the oven and the parts in question.
Ensure that the materials adjacent to the lateral panels of the oven are not
flammable.
Sully - Ft 124a - GB - Rév 06 - Modifié le : 07/10/2013 10/42