User Manual LabModul 240

 

Page 4

 

www.labtec.de

 

5

 

Bedienelemente

 

5

 

Operation Controls

 

5.  operating elements

 

 

A

 

B

 

C

 

F

 

G

 

H

 

D, E

 

1 LCD Display Low Pressure Display

 

2 LCD Display Medium Pressure Display

 

3 Inflate test head, sensing valve

 

4 Empty test head, tactile valve

 

5 Generate overpressure 5 l/min, sensing valve

 

6 Generate vacuum 5 l/min, push button valve

 

7 Relieve low pressure, sensing valve

 

8 Exhalation 10 l/min, switching valve

 

9 Inhalation 10 l/min, switching valve

 

10 Fill CPS, switching valve

 

11 Empty CPS, switching valve

 

12 Relieve medium pressure, tactile valve

 

 

 

A

 

test stand housing

 

B

 

Panel (optional)

 

C

 

Test head / breathing connection

 

D

 

Medium pressure Device connection (plug 

 

nipple)

 

 

Medium pressure regulator connection 

 

(coupling)

 

 

CPS 

-

 Filling connection and device 

 

venting

 

 

Power supply 230 V AC with switch

 

 

 

USB interface

 

 

LED USB signals reception

 

 

LED USB signals transmission

 

 

LED + 24 V present

 

 

ED + 5 V present

 

 

H

 

 

I

 

J

 

K

 

L

 

1, 2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

 

11

 

12

 

or operating terminal via the test software

 

Summary of Contents for LabModul 240 Series

Page 1: ...2 3 device description 3 4 technical data 3 5 operating elements 4 6 component description 5 7 description of the operating elements 5 8 commissioning 6 9 care and maintenance 6 Attachments Performin...

Page 2: ...ed and certified Labtec service technician and tested and calibrated by him or her using a Labtec calibration device The list of current certified employees training partners and service technicians i...

Page 3: ...fitted at the factory Connection requirements A 230 240 V 50 60 Hz power supply is requi red to operate the test stand As medium pressure connection Euro coupling and nipple are available as standard...

Page 4: ...10 l min switching valve 9 Inhalation 10 l min switching valve 10 Fill CPS switching valve 11 Empty CPS switching valve 12 Relieve medium pressure tactile valve A test stand housing B Panel optional C...

Page 5: ...um pump With the built in vacuum pump the required air currents are generated and the probe is infla ted or deflated The desired air flow rate can be set in the software from 2 12 l min Processor The...

Page 6: ...g nipple of the medium pressure device connection and the line of the demand valve to the EURO quick coupling of the medium pres sure device connection If the SCBA to be tested does not have a Euro co...

Page 7: ...specific adaptors 1 2 2 Mount mask on test head pull straps tight inflate test head 3 A few seconds is usually long enough 1 2 3 Adjust negative pressure to exactly mbar 5 By means of pressure relief...

Page 8: ...with the setpoint All further tests require high pressure Regulator in conjunction with a Connect the SCBA to the test device Medium pressure hose from the PA regulator of a SCBA must with Device conn...

Page 9: ...ssure flows into the device 3 2 2 Close the bottle of the SCBA Tester DUT are under pressure 3 2 3 Read the medium pressure on the LCD display MP and compare with setpoint 3 2 4 After a specified time...

Page 10: ...pressure is reached 5 1 8 Lower the pressure to the required internal pres sure with the switch 11 if necessary with but ton 12 approach and turn on the stopwatch Setting the required Settling time 5...

Page 11: ...h in EEC Guideline 2016 42 EG and EMC 2014 30 EU including all changes and addendums to date thereto The above mentioned product meets the following standards and guidelines Nous Vous Confirmons que l...

Reviews: