LM3606 PRINT & APPLY SYSTEM
USER’S MANUAL
Page 21
Made in the U.S.A.
© 2021 LabelMill
06/01/2021 Model LM3606
TAMP UNIT OPERATION
Tamp Duration
Tamp duration is used to provide an on timer for the solenoid valve on the main tamp cylinder.
The delay on standard versions can be programmed from 0 to 30.000 seconds in 1/1000 of a
second accuracy. This allows for easy change over from one product height to another without
physically changing the height of the unit. It also allows for precise adjustments of how close the
tamp head comes to the product.
There is flow control adjustment for the valves. It may be necessary to adjust the flow rate on the
tamp solenoid for optimum performance after installation. The adjustment is performed as shown
below. They are set at the factory. The regulators on the vacuum, air assist, and flag valves are for
increasing or decreasing the air pressure as necessary for proper operation. Note: Flag Regulator
not shown below – only supplied with flag applicators
.
2-12
Vacuum
Pump
Flow Control (B)
(Brass Screw)
Air Assist
Regulator
Vacuum
Regulator
Flow Control (A)
(Brass Screw)