LM3612 PRINT & APPLY SYSTEM
USER’S MANUAL
Page 31
Made in the U.S.A.
© 2021 LabelMill
06/01/2021 Model LM3612
SYSTEM PROGRAMMING
•
I/O PANEL
Displays the status of the inputs and outputs. X = On 0 = Off
•
PRODUCT SENSOR
This is an external device that when “activated” starts the application cycle.
PROGRAMMABLE BLOCKS:
Product Delay – Delays the application of the label (x) seconds after the sensor has been activated.
Trigger Edge – Designates whether product sensor is activated at the leading or trailing edge of the product.
Trig On Debounce – Programmable time that a trigger signal must be held for a start cycle to activate.
Trig Off Debounce – Programmable time that input triggers will be ignored for after a completed cycle.
No. of Multiple Feed – How many labels are applied to one product with one signal.
Interval Delay – Amount of time in seconds between multiple fed labels.
Note
: Only active if Multiple Feed quantity is 2 or higher.
Multiple Feed List - Programmable delay between each programmed multiple feed.
•
TAKE UP
This is used to delay the start and stop of the take up motor.
PROGRAMMABLE BLOCKS:
On Delay – Delays (x) seconds after start print before starting take up motor.
Off Delay – Take up runs (x) seconds after end print signal is received from printer.
Jog Takeup –Press the JOG TAKEUP button to jog the motor.
•
TAMP SET UP
This is used to adjust the different variables related to the tamp cycle.
PROGRAMMABLE BLOCKS:
Tamp Duration – Used to adjust the time that the tamp cylinder valve is actuated. (0.000 to 10.000)
Flag Duration – Used to adjust the time the flag jaws are held open after label application. (00.00 to 30.000)
Head Up Switch Type – type:
normally open-
standard, none
Head Up Debounce – Debounce is used to allow time for the tamp cylinder to settle on return. (0 to 0.500)
Vacuum Release – Used to release label when tamping on light products. (0.000 to 10.000)
Vacuum Delay On – Used to reduce label flutter when feeding large labels while tamping. (0.000 to 6.000)
Tamp Sync Logic – Used to reverse tamp sync outputs.
Air Assist Delay -– Used to delay the Air Assist output (0.000 to 1.000 seconds)
•
COUNTER
Used to reset the internal counter of the control.
PROGRAMMABLE BLOCKS:
Batch Preset - Used to set Batch Counter. Once reached, the applicator will Inhibit.
Clear Batch Counter - Used to clear the programmed batch counter.
Clear Total Counter - Clears the system Total Counter
3-03