background image

4

1) OVERVIEW OF THE SYSTEM

OUTER SIDE

INNER SIDE

AUTOMATION POWER 

SUPPLY

230V~

Internal movement and presence sensor for door opening and safety during closing

Emergency opening button

Digital programmer

External movement and presence sensor for door opening and safety during closing

Opening safety sensor

Key button

ETERNA automation

1

2
3
4
5
6
7

2) TECHNICAL SPECIFICATIONS OF THE AUTOMATION ETERNA

SLIDING DOOR AUTOMATION MODEL

ETERNA 70D-90D-150D-200D 

(2 leaves)

ETERNA 70S-90S-150S-200S 

(1 leaf)

TELESCOPIC DOOR AUTOMATION MODEL

ETERNA 300T 

(4 leaves)

ETERNA 300T DX/SX 

(2 leaves)

Power supply

230V~ 50Hz +/‑ 10%, 115V~ 60 Hz +/‑ 10% 

Max. power

100 W

Frequency of use

continuous

Pause time

Max. 30 seconds

Operating temperature

‑15°C to +50°C

Protection class

IP22

Power supply for external accessories

24 Vdc

Dimensions of ETERNA 90 (H x D)

100 x 135 mm

Dimensions of ETERNA 150 (H x D)

 120 x 150 mm

Dimensions of ETERNA 300T (H x D)

120 x 210 mm

Summary of Contents for ETERNA 70

Page 1: ...MANUAL TRANSLATION OF THE ORIGINAL INSTRUCTIONS PEDESTRIAN AUTOMATIC SLIDING DOOR ETERNA 70 90 150 200 300T EN Rel 2 1 01 2020 CD0709EN MU EN ETERNA ETERNA 70 ETERNA 90 ETERNA 150 ETERNA 200 ETERNA 3...

Page 2: ...maintenance conditions provided for by LABEL The equipment can be used by children of at least 8 years of age and by people with reduced physical sensory or mental skills or by inexperienced people p...

Page 3: ...MECHANICAL KEY SELECTOR 5 4 2 DIGITAL PROGRAM SELECTOR ET DSEL 6 4 2 1 GENERAL PROGRAMMING MENU 8 4 2 2 PASSWORD 9 4 2 3 LANGUAGE 11 4 2 4 SELECTOR OPTIONS 12 4 3 DIGITAL PROGRAM SELECTOR T NFC 13 4...

Page 4: ...SPECIFICATIONS OF THE AUTOMATION ETERNA SLIDING DOOR AUTOMATION MODEL ETERNA 70D 90D 150D 200D 2 leaves ETERNA 70S 90S 150S 200S 1 leaf TELESCOPIC DOOR AUTOMATION MODEL ETERNA 300T 4 leaves ETERNA 300...

Page 5: ...had met the obstacle to avoid further impact If during the closing motion the door collides against an obstacle it stops and opens back When it closes again later it slows down near the point where i...

Page 6: ...m To disable entry detection on external Radar input Open door program The door remains motionless in the position of complete opening Manual free door Automatic operation is disabled and the door can...

Page 7: ...ng press the F2 button once the F2 symbol appears on the display To disable chemist s opening press the F2 button once more the F2 symbol goes off on the display F1 Door opening command Pressing the b...

Page 8: ...unauthorised access to the ET DSEL digital programmer DIAGRAM 1 The paragraphs below explain the procedure to be followed to manage the user password and to select the language SECTION RESERVED FOR T...

Page 9: ...ET DSEL and changing the work program Using a primary password is optional and must be enabled by system owner The default technical password is A A A A A WARNING When enabling the password be very c...

Page 10: ...procedure Enter the primary password Enter the new service password selecting a combination of 5 characters from the letters A B C D You are prompted to repeat the new password so enter again the pre...

Page 11: ...ct PASSWORD ON OFF Press the button OK F1 Enter the primary password Enter the primary password Press the OFF button F1 to disable user password usage To return to the general programming menu press t...

Page 12: ...others are not displayed Automatic bidirectional program Exit Only Program The buttons in this sub menu are used as follows The button allows to go to the next selection The button F2 allows to return...

Page 13: ...ther activation command To change a work program press the SET button once to exit the Screen Saver function and thus activate the selector the screen will increase its brightness now press SET again...

Page 14: ...the only one that enables to enter the user password area and should therefore be known only by the owner of the store organization in which the door is installed The service password 2 instead is use...

Page 15: ...lock operation with mains power supply on 5 OPERATION IN CASE OF POWER SUPPLY FAILURE If the battery module is installed in the automation automatic door operation is guaranteed by an emergency batte...

Page 16: ...16 6 USE OF THE PANIC EXIT BREAKOUT SYSTEM FOR ESCAPE ROUTES SEMI FIXED LEAF MOBILE LEAF ENGAGEMENT OF THE MOBILE LEAF LEAVES REPOSITIONING DURING CLOSURE...

Page 17: ...rvice centre to solve the issue The symbol is displayed The system has detected a machine operation error Contact the service centre to solve the issue Should any malfunction occur the Customer must c...

Page 18: ...ETERNA Made in Italy by S p A Via Ilariuzzi 17 A S Pancrazio P se 43126 PARMA ITALIA Tel 39 05 21 67 52 Fax 39 05 21 67 52 22 infocom labelspa it www labelspa com LABEL service centre...

Reviews: