5
3) AUTOMATIC DOOR OPERATION
WARNING!!
Always contact the assistance technician before commissioning the door, to learn how the automation works.
Switch on the power supply by means of the system switch.
The automation electronic control unit beeps shortly to indicate that the automatic door is powered.
The first opening command starts a calibration cycle during which the door opening speed is very low until the end of the motion, to find
the stop point; after the delay time has elapsed, the door closes back at normal speed.
3.1) NORMAL DOOR OPERATION
•
When something enters the motion sensors (internal and/or external radar) detection area, the door opens and stays open until the
sensors detect the presence, then once the pause delay has elapsed the door closes back.
•
When the manual door opening button is pressed, the door opens and stays open until the command remains active, then once the
pause delay has elapsed it closes back.
•
If the closing safety sensor detects a presence, the door immediately reopens, and stays open as long as the sensor remains engaged.
•
If the opening safety sensor detects a presence, the door slows down and proceeds very slowly until the opening motion is completed.
•
If during the opening motion the door collides against an obstacle, it stops and closes back.
When it opens again, later, it slows down near the point where it had met the obstacle, to avoid further impact.
•
If, during the closing motion, the door collides against an obstacle, it stops and opens back.
When it closes again, later, it slows down near the point where it had met the obstacle, to avoid further impact.
3.2) DOOR OPERATION IN NIGHT LOCK MODE
•
The door cannot be opened by means of the external and internal radars.
•
The door can only be opened by pressing the OPEN button, or using the Spyco radio‑control, if any.
•
The safety functions (sensors and behaviour in case of obstruction) are active and operate as described in par. 3.1. related to normal
operation.
4) PROGRAM SELECTORS
The program selector allows the user to select the operating mode of the door.
Depending on one's preferences, the EV‑MSEL mechanical key selector or the ET‑DSEL digital programmer can be used.
Each program selector is fully described below.
4.1) EV-MSEL MECHANICAL KEY SELECTOR
OPERATING MODE
Insert and turn the key of the selector EV‑MSEL to select the
desired program.
Open door program
The door remains motionless in the position of complete opening.
Winter reduced opening program
For reducing the opening space
Automatic bidirectional program
The door automatically opens following any opening command.
Automatic unidirectional exit only program
To disable entry detection on external Radar input.
Night lock program
The door can only be opened through the OPEN input or using the SPYCO remote control, if any.
The key can be taken out of the selector when in any position in order to prevent undesired changes to the work program.