![LABA7 Shock Dyno User Manual Download Page 15](http://html1.mh-extra.com/html/laba7/shock-dyno/shock-dyno_user-manual_4564625015.webp)
Shock Dyno
Version: 1.0.23241
Page 15/62
7.
First Launch
This section provides information associated with the first use of the LABA7 Shock Dyno.
Follow the steps below to launch the Shock Dyno for the first time:
1.
Plug the power cable provided with the device into the power connector and plug into the
mains.
2.
Turn the Shock power switch on. The green light on the switch will light up, or the manual
dyno controller will light up.
3.
If powering on the Shock Dyno results in the shortening of an earth leakage circuit breaker,
follow the instructions of RFI Jumper Removal (Section 7.2) to solve the issue.
4.
Press the Emergency Stop Button to disengage the Shock Dyno before mounting the
damper.
5.
Open the safety doors by pulling from the cover side handle.
6.
Place the damper within the top or bottom adapter and secure it.
7.
Adjust the handlebars of a preload crossbar and lower or raise it to align
the damper with the other unsecured adapter and secure it in place.
8.
Before tightening the preload crossbar, ensure the motor is in a bottom position (use a
socket or spanner wrench to adjust the motor so it is placed bottom-wise during the start
of rotation).
9.
If your damper requires a different stroke on the Shock Dyno, follow Changing the Stroke
(Section 7.1) instructions.
10.
Preload the crossbar by pushing it downwards and tightening the handlebars.
11.
Release the Emergency Stop Button.
12.
Power off the Shock Dyno to configure the software.