5.2.
Emergency Stop Button Control
The Emergency Stop button can be activated anytime during operation. To activate the emergency
button:
1.
Press the button to stop any operation.
2.
Rotate the Emergency Stop button to the right to release it and deactivate the emergency
state.
5.3.
Manual Control
Shock Dyno Mid and Heavy models can be controlled via a manual dyno controller:
1.
Adjust the motor frequency by rotating the knob on the manual display.
2.
Press the RUN button to start the Dyno.
3.
Motor frequency can be adjusted while the Dyno is running.
4.
Press the STOP button to stop the Dyno.
ATTENTION: Use the emergency stop button to engage the safety mechanism before
opening the protective lid or removing shocks or forks to disable the Dyno from running by
accident and prevent the risk of injury.