Lab.gruppen Tesira D 120:4T Quick Start Manual Download Page 23

15. Technical Specifications 

D SERIES Tesira Quick Start Guide  rev 1.2.0

23

    

15. Technical Specifications 

D 200:4T/Ta

D 120:4T/Ta

D 80:4T/Ta

General

Processing / Network

Tesira

®

 by Biamp / AVB

Numbers of amplifier channels

4

Total burst power all channels (share among channels with RPM)

20000 W

12000 W

8000 W

Max. Output Power (all ch.’s driven) 

1)

2 ohms

4400 W

3000 W

2000 W

2.67 ohms

5000 W

3000 W

2000 W

4 ohms

4400 W

3000 W

2000 W

8 ohms

2300 W

1900 W

1500 W

16 ohms

1150 W

950 W

750 W

Hi-Z 70 V

3300 W

3000 W

2000 W

Hi-Z 100 V

4700 W

3000 W

2000 W

Max output power single channel (all models) 

1)

2 ohms

4400 W

2.67 ohms

5900 W

4 ohms

4600 W

8 ohms

2300 W

16 ohms

1150 W

Hi-Z 70 V

3300 W

Hi-Z 100 V

4700 W

Amplifier output modules (all models, all channels)

Peak output voltage

194 V

Max output current

67 A

Rational Power Management (RPM)

Regardless of model, any channel has potential to deliver the max single channel output power

(1 channel on D 80:4, 2 channels on D 120:4)

Default voltage limitation (can be lifted with RPM configuration)

194 V

175 V

155 V

Protection features

Current Average Limiter (CAL), Very High Frequency Protection (VHF), Direct Current Protection (DC),

Short Circuit Protection, Current-Clip Limiter, Voltage Clip Limiter, Temperature protection

Amplifier platform

Inter Sample Voltage Peak Limiter (ISVPL)

Configurable Peak voltage threshold and profile

Amplifier gain

Digital configurable amplifier gain 22 - 44 dB

Pilot tone generation and analysis

LoadPilot

Load impedance analysis

Yes

Temperature control

Regulated fans and show must go on limitation (ATL, PTL)

Audio Performance (Amplifier platform with digital input)

THD + N 20 Hz - 20 kHz for 1 W

< 0.05 %

THD + N at 1 kHz and 1 dB below clipping

< 0.04 %

Dynamic range

> 114 dB

Channel separation (Crosstalk) at 1 kHz

> 70 dB

Frequency response (1 W into 8 ohm, 20 Hz - 20 kHz)

+/- 0.05 dB

Internal sample rate / Data path

48 / 96 kHz / 32 bit floating point

Product propagation delay (straight path analog server input -> amp)

3.857 ms / 185 samples @ 48 kHz

Tesira

®

D Series Tesira

®

 system integration

Tesira

®

 expander class device with full integration of amplifier configuration and amplifier surveillance

Device swap

Host name hot swap with full configuration transfer

Auto power down

Configurable auto power down to ultra low consumption SLEEP state

Channel processing

Mute, Level, Signal invert

AVB Audio Network

AVB I/O

4 x 4

Sample rates / transport

48 kHz / Unicast

Network latency

Configurable 1 or 2 milliseconds

Optional 4 channels analog inputs (included in the Ta versions)

Usage

Configurable as Tesira

®

 system inputs or analog failover

Balanced mic or line level input

+ 48 V phantom power and digitally controlled input gain

Maximum input and digital reference

+ 24 dBu

Sampling rate / resolution

48 kHz / 24 bit

Input impedance

8 kOhm

Frequency response (20 Hz - 20 kHz @ 4 dBu)

+/- 0.25 dB

THD + N (20 Hz - 20 kHz @ 0 dB gain + 4 dBu in)

0.006 %

Dynamic range (20 Hz - 20 kHz, 0 dB)

> 108 dB

Cross talk (20 Hz - 20 kHz @ 0 dB gain + 4 dBu in)

> 85 dB

Summary of Contents for Tesira D 120:4T

Page 1: ...DSERIES High Powerinstallationplatform Rev 1 2 0 Quick Start Guide Tesira Variants D 200 4T Ta D 120 4T Ta D 80 4T Ta Incorporating technologies from Item no QSG DSERIES TESIRA...

Page 2: ...e risk of fire or electric shock do not expose this apparatus to rain or moisture 17 Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids such as vases...

Page 3: ...s for the European Electro Magnetic Compatibility EMC directive This equipment has also been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rule...

Page 4: ...3 4 1 Mains connection grounding 3 3 4 2 Speaker output hazard on amplifiers 3 3 4 3 Radio interference 3 3 4 4 Speaker damage 3 3 4 5 Maintenance 3 5 Introduction 6 5 1 Welcome 6 5 2 D Series Two ver...

Page 5: ...12 Signal flow and processing 15 13 Quick Start Tutorial 16 13 1 Software installation and firmware update 16 13 1 1 Tesira Software 16 13 1 2 Firmware update 16 13 2 Network setup 17 13 3 System setu...

Page 6: ...to ensure familiarity with the various configuration and control options Thank you again for placing your confidence in Lab gruppen products 5 2 DSeries Twoversionsavailable D Series is an advanced hi...

Page 7: ...nment software incorporates ESP Equipment Specification Predictor to assist in design equipment specification and commissioning Features controlled by on board DSP Input Gain Sensitivity Input gain se...

Page 8: ...dust filter assembly NOTE Depending on the model the connector kit might include more connectors than applicable for the product you have Select those connectors required for your unit and applicatio...

Page 9: ...s to the amplifier with magnets Hold the front grille with your fingers in each of the side cutouts and slide it gently into place straight from the front NOTE Always ensure the dust filters behind th...

Page 10: ...ich has already been heated by the D Series devices The D Series device is equipped with a sophisticated temperature sensing system which protects it from any overheating which may occur as a result o...

Page 11: ...3 phase delta 208V 208V 2 0 8 V 2 0 8 V L1 L2 L3 Connecting the amplifier in a split phase configuration In two phase split phase configuration there are two phases separated by 180 degrees Connectin...

Page 12: ...h of the button toggles the amplifier between ON and SLEEP state Channel Status and Control 7 LOAD LED for load related status indication 8 AMP LED for amplifier related status indication 9 SIGNAL LED...

Page 13: ...evice configured and ready to participate in a system Device is ready and waiting to receive a configuration Device is not ready to receive a configuration Power Mains power not available Device is ON...

Page 14: ...Ethernet AVB digital audio network 3 Serial control port on a DB 9 for integration control 4 Terminal block connector for Logis I O 4 pins of GPIO and a ground 5 Analog inputs on Tesira Analog versio...

Page 15: ...k in the Tesira output section 4 Level block in the Tesira output section 5 Invert block in the Tesira output section 6 Amplifier gain Digitally implemented for exact control and management of gain st...

Page 16: ...ervers Update Tesira server firmware 1 Download Tesira Firmware from biamp com www biamp com products tesira downloads aspx Locate the Software and Firmware section and download the latest version of...

Page 17: ...t to obtain IP addresses automatically The Tesira device will receive an IP address automatically from a DHCP server if present or assign itself an IP address in the Link local range 169 254 1 0 throu...

Page 18: ...nd a speaker Create Tesira system configuration 1 Open Tesira software 2 Select Labgruppen amplifier from the Object bar I O Blocks 3 Click somewhere in the layout window to place an amplifier in the...

Page 19: ...nd click the reset device button to the left 2 Enter the Equipment table via System equipment table 3 For both the server and the amplifier click the cell in the serial number or host name column and...

Page 20: ...s and highlights the current amplifier NOTE If a firewall is installed on your computer you must give the CAF application permissions to talk to the amplifiers Within CAF you can configure basic ampli...

Page 21: ...ITCH Mains glitch missing cycles was detected on the mains inlet Check mains distribution connection Warning Temperature warning power supply TEMP WARN PSU Power supply temperature approaching critica...

Page 22: ...below thresholds Check load or calibration Warning Speaker damaged SPKR DAMAGED One LoadPilot tone is above or below threshold Check load or calibration Fault No load NO LOAD At least one LoadPilot t...

Page 23: ...ain Digital configurable amplifier gain 22 44 dB Pilot tone generation and analysis LoadPilot Load impedance analysis Yes Temperature control Regulated fans and show must go on limitation ATL PTL Audi...

Page 24: ...tional device software select functionality Mains Power Nominal voltage 100 240 V AC 50 60 Hz Operating voltage 70 265 V AC 45 66 Hz Mains wall plug Selectable on order CEE 7 7 Schuko 230 V 16 A NEMA...

Page 25: ...d by the warranty Units on which the serial number has been removed or defaced will not be eligible for warranty service Lab gruppen shall not be responsible for any incidental or consequential damage...

Page 26: ...zation number Please note for product return 1 Use the original packing 2 Include a copy of the sales receipt your name return address phone and fax number email address and description of the defect...

Page 27: ...27 DSERIESTesiraQuickStartGuide rev1 2 0 Notes Notes...

Page 28: ...CDM BEL UVL CAF ESP ISVPL Iso Float Raised Cosine MESA EQ LimiterMax and LoadLibrary are trademarks of Lab gruppen AB Tesira is a trademark of Biamp Systems All other trademarks remain the property of...

Reviews: