Lab.gruppen Tesira D 120:4T Quick Start Manual Download Page 10

8. Cooling and fan operation 

10    

D SERIES Tesira Quick Start Guide  rev 1.2.0

8. Cooling and fan operation 

D Series devices use a forced-air cooling system with airflow from front to rear, allowing high continuous power 
levels without thermal problems. To facilitate maximum air flow, ensure that no objects such as rack doors or 
lids are placed at the front or rear of the rack. Never attempt to reverse the airflow. Make sure an adequate air 
supply is provided in front of the D Series device, and that the rear of the device has sufficient space to allow 
air to escape. It is recommended to keep the ambient temperature around the device as cool as possible. An 
increased temperature can have a significant negative impact on the expected lifetime on the components 
inside the D Series device. 

NOTE: Fit solid blanks (not ventilation blanks) to unused rack spaces to ensure effective air circulation. Leaving 
gaps in between items of equipment degrades the effectiveness of forced-air cooling. 

If installing one or more D Series devices in a rack with other fan-cooled equipment, confirm that all other 
equipment also uses front-to-rear airflow for cooling. If this precaution is not observed, there is a risk of 
overheating, as units with the reverse airflow will be drawing in air which has already been heated by the 
D Series devices.

The D Series device is equipped with a sophisticated temperature sensing system which protects it from any 
overheating which may occur as a result of inadequate ventilation.

9. Operating voltage 

D Series has a universal power supply and its mains nominal and operating voltages are specified in the Technical 
Specifications (pages 22-23). D Series can be ordered with a variety of mains plugs. If the mains plug (AC plug) 
fitted to the mains cable (AC cord) is not appropriate for your country it can be removed and a locally-sourced one 
fitted instead. If you are not 100% confident of your competence to replace the mains plug (AC plug), the task 
should be carried out by qualified personnel.

NOTE: In-rush current is controlled and limited during the soft-start sequence. This enables multiple D Series 
Devices on the same AC mains circuit to be turned on simultaneously. 

9.1. Low voltage country considerations 

Although the D Series has a wide range of operating mains voltage, some considerations can be applicable for 
low voltage regions. D Series performs well throughout the specified nominal voltage range but has slightly better 
efficiency at higher voltages. For regions with nominal voltage below 140 V, one could consider connecting the 
amplifier in a three-phase delta or two phase split-phase configuration.

NOTE: Following connections applicable only for resulting voltage inside the amplifiers nominal voltage range.

Summary of Contents for Tesira D 120:4T

Page 1: ...DSERIES High Powerinstallationplatform Rev 1 2 0 Quick Start Guide Tesira Variants D 200 4T Ta D 120 4T Ta D 80 4T Ta Incorporating technologies from Item no QSG DSERIES TESIRA...

Page 2: ...e risk of fire or electric shock do not expose this apparatus to rain or moisture 17 Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids such as vases...

Page 3: ...s for the European Electro Magnetic Compatibility EMC directive This equipment has also been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rule...

Page 4: ...3 4 1 Mains connection grounding 3 3 4 2 Speaker output hazard on amplifiers 3 3 4 3 Radio interference 3 3 4 4 Speaker damage 3 3 4 5 Maintenance 3 5 Introduction 6 5 1 Welcome 6 5 2 D Series Two ver...

Page 5: ...12 Signal flow and processing 15 13 Quick Start Tutorial 16 13 1 Software installation and firmware update 16 13 1 1 Tesira Software 16 13 1 2 Firmware update 16 13 2 Network setup 17 13 3 System setu...

Page 6: ...to ensure familiarity with the various configuration and control options Thank you again for placing your confidence in Lab gruppen products 5 2 DSeries Twoversionsavailable D Series is an advanced hi...

Page 7: ...nment software incorporates ESP Equipment Specification Predictor to assist in design equipment specification and commissioning Features controlled by on board DSP Input Gain Sensitivity Input gain se...

Page 8: ...dust filter assembly NOTE Depending on the model the connector kit might include more connectors than applicable for the product you have Select those connectors required for your unit and applicatio...

Page 9: ...s to the amplifier with magnets Hold the front grille with your fingers in each of the side cutouts and slide it gently into place straight from the front NOTE Always ensure the dust filters behind th...

Page 10: ...ich has already been heated by the D Series devices The D Series device is equipped with a sophisticated temperature sensing system which protects it from any overheating which may occur as a result o...

Page 11: ...3 phase delta 208V 208V 2 0 8 V 2 0 8 V L1 L2 L3 Connecting the amplifier in a split phase configuration In two phase split phase configuration there are two phases separated by 180 degrees Connectin...

Page 12: ...h of the button toggles the amplifier between ON and SLEEP state Channel Status and Control 7 LOAD LED for load related status indication 8 AMP LED for amplifier related status indication 9 SIGNAL LED...

Page 13: ...evice configured and ready to participate in a system Device is ready and waiting to receive a configuration Device is not ready to receive a configuration Power Mains power not available Device is ON...

Page 14: ...Ethernet AVB digital audio network 3 Serial control port on a DB 9 for integration control 4 Terminal block connector for Logis I O 4 pins of GPIO and a ground 5 Analog inputs on Tesira Analog versio...

Page 15: ...k in the Tesira output section 4 Level block in the Tesira output section 5 Invert block in the Tesira output section 6 Amplifier gain Digitally implemented for exact control and management of gain st...

Page 16: ...ervers Update Tesira server firmware 1 Download Tesira Firmware from biamp com www biamp com products tesira downloads aspx Locate the Software and Firmware section and download the latest version of...

Page 17: ...t to obtain IP addresses automatically The Tesira device will receive an IP address automatically from a DHCP server if present or assign itself an IP address in the Link local range 169 254 1 0 throu...

Page 18: ...nd a speaker Create Tesira system configuration 1 Open Tesira software 2 Select Labgruppen amplifier from the Object bar I O Blocks 3 Click somewhere in the layout window to place an amplifier in the...

Page 19: ...nd click the reset device button to the left 2 Enter the Equipment table via System equipment table 3 For both the server and the amplifier click the cell in the serial number or host name column and...

Page 20: ...s and highlights the current amplifier NOTE If a firewall is installed on your computer you must give the CAF application permissions to talk to the amplifiers Within CAF you can configure basic ampli...

Page 21: ...ITCH Mains glitch missing cycles was detected on the mains inlet Check mains distribution connection Warning Temperature warning power supply TEMP WARN PSU Power supply temperature approaching critica...

Page 22: ...below thresholds Check load or calibration Warning Speaker damaged SPKR DAMAGED One LoadPilot tone is above or below threshold Check load or calibration Fault No load NO LOAD At least one LoadPilot t...

Page 23: ...ain Digital configurable amplifier gain 22 44 dB Pilot tone generation and analysis LoadPilot Load impedance analysis Yes Temperature control Regulated fans and show must go on limitation ATL PTL Audi...

Page 24: ...tional device software select functionality Mains Power Nominal voltage 100 240 V AC 50 60 Hz Operating voltage 70 265 V AC 45 66 Hz Mains wall plug Selectable on order CEE 7 7 Schuko 230 V 16 A NEMA...

Page 25: ...d by the warranty Units on which the serial number has been removed or defaced will not be eligible for warranty service Lab gruppen shall not be responsible for any incidental or consequential damage...

Page 26: ...zation number Please note for product return 1 Use the original packing 2 Include a copy of the sales receipt your name return address phone and fax number email address and description of the defect...

Page 27: ...27 DSERIESTesiraQuickStartGuide rev1 2 0 Notes Notes...

Page 28: ...CDM BEL UVL CAF ESP ISVPL Iso Float Raised Cosine MESA EQ LimiterMax and LoadLibrary are trademarks of Lab gruppen AB Tesira is a trademark of Biamp Systems All other trademarks remain the property of...