background image

MANUAL FOR USE AND MAINTENANCE

LSC 006 REV. 01

               5

1.3

READ CAREFULLY THE FOLLOWING INSTRUCTIONS AS THEY
PROVIDE IMPORTANT WARNINGS FOR THE SAFE USE AND
MAINTENANCE OF THE MACHINE.

This equipement is to be used only for the purpose it was intended for and needs to be installed in a place
suitable to its use. Any other use is therefore to be considered as improper and irrational. The manufacturer
is not liable for any damage caused by improper, wrongful or unreasonable use.

Installation must be carried out according to local regulation and to the manufacturer’s instructions. A wrong
installation may cause damage to animals, people or things. The manufacturer is not liable for any damage
caused by an improper installation.

The electric safety of this appliance will be fully achieved only after its proper and correct installation
to ground as required by laws in force.

It is necessary to have qualified personnel checking this important requirement. The manufacturer is not
liable for damage caused by the lack or inefficiency of a correct installation to ground.

The use of any electrical appliance requires observance of the following important rules:

Do not touch the appliance with wet or damp hands or feet.

Do not use the appliance barefooted.

Do not pull the power feeding cable to unplug the appliance.

Do not allow children or unqualified personnel to use the appliance.

Before doing any maintenance or cleaning operation, disconnect the appliance from the electric main
source.

In case of damage or malfunction of the machine or damage of the electric feeding cable, turn the machine
off completely without trying to fix it yourself. Call the nearest authorized Service Centre.

In order to grant the proper efficiency and operation of the equipment, it is required to follow the
manufacturer’s instructions carrying out a regular maintenance program.

The machine has a protection level against water IPX2.

The protection from electric shocks of the machine is class I.

The appliance is supposed to operate in a place where the environment temperature is within the range +5

°

C  and 40

°

C.

The appliance is not supposed to operate in the  external environment, that is to say directly subject to
atmospherics

.

The appliance is supplied without water in the boiler, in order to avoid that exposures to low
temperatures could damage it. For the same reason, in case the appliance should remain unused
for a long time, remove water from the boiler before disconnecting it.

The non-compliance with what above stated could jeopardize proper function of the appliance and
its life.

In case the appliance should remain unused for a long time in a place, where the temperature is lower
than 0

°

C, before starting it again, call a technical service centre so as to have it being checked.

Summary of Contents for S1 Rossini

Page 1: ... 8 40033 Casalecchio di Reno Bologna Italy Tel 39 051 611 10 11 Fax 39 051 611 10 40 E mail info laspaziale com Web Site www laspaziale com M A N U A L F O R U S E A N D M A I N T E N A N C E Rossini Rossini Rossini LSC 006 REV 01 ...

Page 2: ......

Page 3: ...NG TEMPERATURE OF THE MACHINE page 9 3 1 DOSES PROGRAMMING 9 3 2 HOT WATER DELIVERY FOR INFUSIONS 10 3 3 STEAM DELIVERY 10 Chap 4 ALARMS DESCRIPTION page 11 4 1 LACK OF WATER INSIDE THE TANK 11 4 2 DAMAGED WATER DOSING SYSTEM FOR COFFEE only in the automatic version 11 4 2 DAMAGED TEMPERATURE MEASUREMENT SYSTEM 11 4 3 DAMAGED TRIAK 11 Chap 5 ORDINARY MAINTENANCE ON THE MACHINE page 12 Chap 6 DIAGR...

Page 4: ...ended to grant an easy maintenance or to clear up important operations 1 1 PLATES The present manual is enclosed with the machine and is supposed to be given to the user 1 2 MACHINE OUTFIT 1 1 filterholder for 2 cups 1 set of filters 1 set of shower heads 1 tool to remove shower heads 1 coffee doser 1 manual coffee tamper 1 brush C B A D F E G La Spaziale S p A Macchine per caffè espresso via E Du...

Page 5: ...able to unplug the appliance Do not allow children or unqualified personnel to use the appliance Before doing any maintenance or cleaning operation disconnect the appliance from the electric main source In case of damage or malfunction of the machine or damage of the electric feeding cable turn the machine off completely without trying to fix it yourself Call the nearest authorized Service Centre ...

Page 6: ...ren from being hurt Place the machine on a stable bearing surface by lifting it from its base The machine is to be installed so that the disconnection plug from the electric main source remains accessible The installation should be carried out in places where the use and maintenance are restricted to qualified and trained staff Before connecting the plug into the socket of the electric system plea...

Page 7: ...chine at the same time lights from 14 to 21 turn on fixed for about a second checking of the electronic part 2 Thecontrollightcorrespondingtothesettemperaturestartsflashingtoindicatethatthemachineisbeing heated up 3 Fasten the filterholder 11 to the brewing group 10 4 Wait until the set temperature is reached by checking that the lights on the control panel 9 gradually turn on as temperature rises...

Page 8: ...r on the upper edge of the filterholder and press it with the suitable coffee tamper provided 3 Firmly fasten the filterholder 11 to the brewing group 10 4 Place one or two cups below the filterholder 11 5 Press the one cup button 24 to make one coffee and the two cup button 25 to make two to start the delivery Once the desired quantity of coffee programmed is reached the delivery automatically st...

Page 9: ...eds 16 15 14 gradually turn on and here every led corresponds to a 1 C decrement of the temperature set For example if the set temperature is 105 C and you proceed to turn on the leds 19 and 20 the new set temperature becomes 105 2 107 C The value of the operating temperature of the machine can be changed only in order to improve the final result in the cup according to the coffee blend used 3 1 D...

Page 10: ... clockwise in order to stop the delivery 5 Throw away the water inside the pitcher and pour in the drink to be heated up 6 Insert the steam wand 2 into the pitcher 7 Turn the steam knob 6 anticlockwise regulating the steam flow according to need 8 At the end of the heating phase of the drink stop the steam delivery by turning the steam knob 6 clockwise 9 Remove the steam wand 2 from the pitcher an...

Page 11: ...out stopping at the programmed dose in order to stop it press the one coffee 24 or two coffee 25 button If this alarm appears call the authorised technical assistance centre 4 3 DAMAGED TEMPERATURE MEASUREMENT SYSTEM This is a blocking alarm and it appears when the control lights 20 21 turn on fixed This alarm shows when temperature rises over 145 C temperature probe in short circuit or is inferio...

Page 12: ...esidues by using a rough sponge REGULAR MAINTENANCE OF THE EQUIPMENT BY THE USER In order to maintain the efficiency and its proper operation it is necessary to follow the manufacturer s instructions carrying out a regular cleaning and maintenance program WARNING The cleaning and maintenance operations must be carried out by the user according to the manufacturer s instructions as specified below ...

Page 13: ...MANUAL FOR USE AND MAINTENANCE LSC 006 REV 01 13 DIAGRAMS 6 1 ELECTRIC DIAGRAM RC TSC TRIAK 1 2 1 2 CONTROL BOARD TOUCHPAD SER 1 SER 2 1 2 S2 SL 1 4 P EV GR EV H FUSE 5A 230 V PHASE NEUTRUM GND 6 ...

Page 14: ...UAL FOR USE AND MAINTENANCE 14 LSC 006 REV 01 6 2 ELECTRIC DIAGRAM AUTOMATIC VERSION RC TSC TRIAK 1 2 1 2 SER 1 SER 2 1 4 1 2 F S2 SL 1 4 P EV GR EV H 230 V GND CONTROL BOARD TOUCHPAD FUSE 5A PHASE NEUTRUM ...

Page 15: ...ANCE LSC 006 REV 01 15 6 3 CONTROL BOARD DIAGRAM 6 5 LED CIRCUIT DIAGRAM F S1 JP T2 SER1 PUMP PHASE EV GR EV H NEUTRUM NEUTRUM F2 F1 xxx F3 JP3 M1 M8 M3 M2 P2 V M3 F1 F2 in F2 out M2 M1 M1 SER 2 IN HALL 12V GND 6 4 TRIAK DIAGRAM ...

Page 16: ...eating element Connection control panel on control board Connection control board on control panel Flowmeter Phase inlet into the triak feeding the group heating element Phase outlet from the triak feeding the group heating element Brewing group temperature probe Ventilator connection for triak cooling Safety thermostat for brewing group heating element Brewing group heating element Water level se...

Page 17: ...06 REV 01 17 6 7 COMPONENTS V A P O R E V A P E U R V A POR STEA M D A M P F 6 5 7 8 9 2 4 3 11 1 10 12 28 13 14 15 16 17 18 19 20 21 22 24A 23 25A 26 27 13 14 15 16 17 18 19 20 21 22 24 23 25 26 27 SEMIAUTOMATIC VERSION AUTOMATIC VERSION ...

Page 18: ... water temperature for coffee 95 c 17 Control light indicating water temperature for coffee 100 c 18 Control light indicating water temperature for coffee 105 c 19 Control light indicating water temperature for coffee 110 c 20 Control light indicating water temperature for coffee 120 c 21 Control light indicating water temperature for coffee 130 c 22 Electric connection control light 23 Hot water ...

Page 19: ...01 04 Realized by STUDIO 80 Bologna Italy ...