33
17.2. Pressed Wood BRIQUETTES AUTOMATIC operation
PROBLEM
POSSIBLE CAUSES
POSSIBLE SOLUTIONS
It switches from
AUTOMATIC to
MANUAL
Press and hold the P1 button
SLEEP function activated
Press button P1 for more than 3 seconds
Disable the SLEEP delay feature
Presence of an
ALARM
Briquettes unloading
Other alarms displayed on the
screen
Briquettes feeder empty, feed briquettes and reset alarm by pressing and
holding the P1 button
See UNLOADING ALARM after feeding the first briquette
Call Technical Support
UNLOADING
ALARM after
feeding the first
briquette
Insufficient ash layer
Open the door and with a poker increase the thickness of the embers in-
troducing a briquette under the COMB on the ashes. Reset the alarm and
set the AUTOMATIC feature
The DISPLAY
stays off
No power supply
Electrical cable not connected
The master switch of the stove
is off
Open hearth door
Open BRIQUETTES feed door
Overheating safety thermostat
in action
Faulty fuse
Electrical fault
Reset power supply
Connect the electrical cable
Bring the master switch of the stove to position 1
Close the door
Close the door
Reset the safety thermostat
Replace the fuse.
In case of electrical fault call Technical Support
THE BRIQUETTE
remains blocked
during ascent
No power supply
Electrical fault
Mechanical fault
Check the doors are closed and wait for power to return
Check the fuse and call Technical Support
Check there are no jams
Call Technical assistance
During feeding
the INFEED
DOOR in the
combustion
chamber
remains partially
open
No power supply
Electrical fault
Mechanical fault
Reset power supply
Call Technical Support
The comb lifting
has caused the
ceramic GLASS
TO BREAK
During automatic operation
wood or briquettes were fed
manually over the COMB
Put the stove in manual mode, wait for it to switch off, and then call Techni-
cal Support
Summary of Contents for FUTURA
Page 2: ......
Page 58: ...FUTURA 58 8291003 IT EN DE RU 16 0 C 60 C 10 C 60 C 95 230 50 60 2 5 A 250 16 1 P1 16 2...
Page 59: ...FUTURA 8291003 IT EN DE RU 59 60 16 3 LED SLEEP SLEEP SLEEP stby GND I2 F1...
Page 60: ...FUTURA 60 8291003 IT EN DE RU 17 17 1 20 20 17 2 P1 SLEEP 3 P1 SLEEP 1...
Page 61: ...FUTURA 8291003 IT EN DE RU 61 1...
Page 70: ...FUTURA 8291003 IT EN DE RU 45 A A 19 19 MA E 19 DIMENSIONS 19 DIMENSIONI...
Page 71: ...FUTURA 46 8291003 IT EN DE RU...
Page 72: ...FUTURA 8291003 IT EN DE RU 47...
Page 73: ...FUTURA 48 8291003 IT EN DE RU...
Page 74: ......