ChANgiNg yoUR BATTERy
1. Open safe door.
2. Remove battery box cover by pulling the front
portion away from the safe door.
3. The connector is easily removed by
unsnapping it from the two terminals on the
top of the battery.
Never Pull on the Battery Leads
4. Connect a new 9-Volt Alkaline battery to the
battery clip.
5. Push the battery and the leads completely up
into the battery compartment.
6. Replace the cover and test the unit several
times before closing the door
ChANgiNg yoUR BATTERy
1. Open safe door.
2. Remove battery box cover by pulling the front
portion away from the safe door.
3. Remove six “C” cell Alkaline batteries.
4. Insert six new “C” cell batteries.
5. Replace the cover and test the unit several
times before closing the door.
2788 Small Battery Box
or 2789 Small Battery Alarm Box
4001 Large Battery Box or 4002
Large Battery/Alarm Box
3. Enter Manager Combination and hold down
last digit of combination until unit double-
signals twice and the LED stays on.
4.
PRESS 7
. Unit signals once and Audit will
be sent.
5. Disconnect Interface Cable from PC
and keypad.
DUAL MoDE oPERATioN
1. Additional User(s) must be active to use this
function. (See
ACTiVATiNg USER
.)
2. If Time Delay is active, one valid combination
will start Delay period.
• Both combinations required to open
lock in Open period.
NoTE:
In Dual Mode a valid user combination
must be entered before the Manager
Combination in order to use Manager Functions
1, 2, and 3.
TiME DELAy oVERRiDE (User #9)
• This feature must be enabled during
Lock Setup.
• If User 9 is disabled or deleted this feature
will no longer function.
Entry of Override combination during Delay
period will open the lock.
SiLENT DURESS ALARM
(If feature is enabled
AND optional Alarm Box is connected to an
alarm system.)
• Enter last digit of combination one number
higher or one number lower.
Example: Combination: 1-2-3-4-5-6
Duress: 1-2-3-4-5-5
or
1-2-3-4-5-7
• The lock will open without any indication that
the duress signal has been sent.
DiSABLE oPENiNg
(Feature is active by
default. Alarm Box must be connected.)
External signal to the alarm box will disable the
lock opening by a valid combination. Lock
indicates disabled by signaling 6 times once the
combination is entered.
• If in time delay, the lock will not open
during the open period.
WRoNg TRy PENALTy
• Entry of four (4) consecutive invalid
combinations starts a 5-minute delay period.
LED flashes red at ten (10) second intervals.
• At the end of the delay period, two more
consecutive invalid combinations will restart
an additional 5-minute delay period.
During delay period a single keystroke will
respond with three signals.
BATTERy LoW WARNiNg
• Repeated LED flashing beeping after an
opening indicates that the battery is low and
needs immediate replacement. It is
recommended that batteries be replaced at
least once a year.
• Uses alkaline battery only. (Example:
Duracell™ or Eveready™ alkaline batteries.)
• When the battery level becomes too low to
safely operate the lock any key press will give
a low battery warning, and the battery
must be changed before the lock will operate.
if battery is depleted and will not allow lock
to open, follow instructions found in the User
instructions for your keypad. Lock contains
a non-volatile memory; even with batteries
removed the lock will retain all programming.
Mounting instructions available at www.
kaba-mas.com.
WARNiNg: The port for the audit cable is a data port only. Connecting power to this port will
damage the system.