background image

2. Press the “0” key.
3. Enter your NEW Manager Combination; re-
  enter new combination to confirm.
4. If a mistake is made wait thirty (30) seconds
  and repeat steps 

1 - 3

.

5. Test unit operation several times before
  closing the door.

oPERATioNAL MoDE
oPENiNg ThE LoCK (Manager or User)

1. Enter valid Manager or User combination.
2. The unit will indicate a valid combination entry 
  with a double signal.
3. Within four (4) seconds open lock by either
  rotating the keypad to open position
  (clockwise) or turning the handle to the
  open position.
4. Pull door open.
  •  Invalid Combination Entry - Unit will signal 
    three (3) times.
5. Close the door, and check the locked 
  status of the container with the handle of 
  the boltworks.

ChANgiNg CoMBiNATioN (Manager or User)

Always perform this operation with the
door open!

Each combination must be changed 
independently.

1. Enter existing combination and hold down the 
  last digit until unit double signals twice and 
  the LED stays on.
2. Press the “0” key.
3. Enter your NEW combination, then re-enter 
  NEW combination to confirm.
4. If a mistake is made wait thirty (30) seconds
  and repeat steps 

1 - 3.

5. Test unit operation several times before
  closing the door.
  • 

Valid Combination Entry

 - Double signal 

    after valid combination is entered.
  • 

invalid Combination Entry

 - Triple signal 

    and old combination is still valid.

ACTiVATiNg/REiNSTATiNg USER
(Manager only)

1. Enter Manager combination and hold down 
  last digit of combination until unit double 
  signals twice and the LED stays on. 
2.  PRESS 1. Unit signals twice.
3. Press User number, 1 to 9. Unit signals twice.
4. Enter NEW combination, then re-enter NEW 
  combination to confirm.
5. If a mistake is made wait thirty (30) seconds
  and repeat steps 

1 - 4

.

    • 

Valid Combination Entry

 - Double 

      signal after valid combination is entered.
    • 

invalid Combination Entry

 - Triple 

      signal and old combination is still valid. 

DiSABLE USER (Manager only)

1. Enter Manager combination and hold down 
  last digit of combination until unit double 

  signals twice and the LED stays on.
2. PRESS 2. Unit signals twice.
3. Press User number, 1 to 9. Unit signals once.
4. User is temporarily disabled.
5. If a mistake is made wait thirty (30) seconds
  and repeat steps 

1 - 3

.

DELETE USER (Manager only)

1. Enter Manager combination and hold down 
  last digit of combination until unit double 
  signals twice and the LED stays on. 
2. PRESS 3. Unit signals twice.   
3. Press User number, 1 to 9. Unit signals once.
4. User is deleted.
5. If a mistake is made wait thirty (30) seconds
  and repeat steps 1 - 3.

SET/ChANgE TiME DELAy VALUES

1. Enter Manager combination and 

hold down 

  last digit of combination until unit double 
  signals and the LED stays on.

2. 

PRESS 9.

 Unit signals twice.

3. Enter two-digit Delay period value (00 to 99 
  minutes) followed by the two-digit Open 
  period value (00 to 19 minutes). 
  •  Unit will signal twice, if accepted. 
  •  Unit will signal three times, if invalid.
4. Re-enter the Delay and Open period values, 
  to confirm. 
  •  Unit will signal twice and feature is active. 

NoTE: 

Entering 0000 will deactivate the Time 

Delay Feature.

NoTE: 

If Time Delay is active it may only be 

deactivated or delay value decreased in Open 
Period.

TiME DELAy – LoCK RESPoNSE

•  During the Delay Period the LED will flash 
  every second.
•  During the Open Period the LED will flash 
  twice a second, and the Entry Device will 
  beep every 10 seconds.

TiME DELAy oVERRiDE

 

(If feature is enabled)

•  Must add User 9. (See 

ADD USER

)

    -  If User 9 is disabled or deleted, this 
      feature will no longer function.
•  Entry of Override combination during Delay 
  period will open the lock.

NoTE: 

If Time Delay is enabled, User 9 can only 

be added during the Open period.

RECEiVE AUDiT (Manager only)

This function requires Serial Interface (P/N 
43087) and LGVIEWER Software

1. Plug Interface into PC and open LGView 3X
  software on PC.
2. Connect Interface to front of keypad and click
  safe icon button on the PC software to
  begin acquisition.