background image

Available users and default codes 

 

User 

User ID 

Default Code 

Master 

N/A 

9-8-7-6-5-4-3-2 

Manager 

N/A 

1-2-3-4-5-6 

Users 2-9 

2-9 

Deleted 

–  Must  be  added 

by the Manager 

 
Default  codes  must  be  changed  immediately.  The 
master code contains 8 digits, all other codes contain 6 
digits. 
 

Acoustic and visual signals 

The lock system will indicate status with beeps and LED 
flashes on the keypad 
 

Signal 

Indication 

Short beep & LED flash 

Button pressed correctly 

Double beep & LED flash 

Code or function entered 
correctly 

Triple beep & LED flash 

Code or function entered 
incorrectly 

5 beeps on a key press 

Remote disable is active 

LED flash every second 

The lock is in time delay 

LED flash twice per second 
and beep every 10 
seconds 

The lock is in the open window 

LED flash every 10 
seconds 

The lock is in penalty 

Repeated beeping and 
flashing during opening 

Low battery warning 

 

Command Keys 

 
All  of  the  functions  available  to  the  master,  manager 
and users are accessible using command keys. To use 
a  command  key,  enter  a  valid  code  and  hold  down  the 
last digit until 2 sets of double beeps have sounded and 
the LED stays on. Press the relevant command key and 
follow the remaining instruction. 

 

Key 

Function 

Change Code 

Add  a  user  /  enable  a  disabled  user  /  check  user 
status 

Disable a user 

Delete a user 

Download an audit 

Enter time delay values 

 

Standard Features 

 

Codes & Users 

 

The master code holder can:

 

  Change Code 

  Audit the lock 

 

The manager code holder can:

 

  Open the lock 

  Add,  enable,  disable 

and delete users 

  Check user status 

  Change code 

  Audit the lock 

  Set time delay values 

 

There are 8 user codes numbered 2-9. Users can: 

  Open the lock 

  Change code 

 

Time delay 

Time  Delay  is  a  feature  requiring  a  period  of  time  to 
elapse  before  the  lock  system  can  be  opened,  to 
prevent  a  user  being  forced  to  open  the  lock 
immediately.  
The Time Delay period can be set from 1 

– 99 minutes  

The Open Window is the period of time after time delay 
has expired during which the lock can be opened which 
can be set from 1-19 minutes. 

 

Low battery warning 

If  the  battery  is  running  low,  repeated  beeping  during 
opening will indicate the need to change the battery. 

 

Penalty 

Entry  of  4  consecutive  incorrect  codes  results  in  a  5 
minute  penalty  -  all  lock  functions  are  disabled.  During 
penalty,  the  LED  flashes  at  10  second  intervals  and  a 
key  press  will  result  in  3  beeps.  After  the  penalty  has 
expired,  2  further  consecutive  incorrect  codes  will 
initiate the penalty. Once a correct code is entered, the 
penalty trigger resets to 4 wrong tries. 

 

Check user status 

The  status  of  users,  whether  enabled,  disabled  or 
deleted may be audited using the keypad. 

 

Optional Features Available On Request 

 

Audit 

An  audit  can  be  taken  of  the  last  512  lock  events, 
showing  opening  activity  and  other  operations.  The 
audit shows time and date information. To take an audit, 
a  PC  is  required  along  with  software  and  a  cable 
interface kit, items sold separately. 

 

Dual mode 

The  lock  system  can  be  set  up  so  that  2  codes  are 
required to open the lock and carry out manager special 
functions.  

 

Alarm signals 

The lock can be set up so that a silent signal is sent to 
an  alarm  system  when  a  duress  code  is  entered,  in 
addition to one of the following options: 

  When  an  input  signal  is  received  from  an  alarm 

system, the lock is disabled from opening.  

  When  an  input  signal  is  received  from  an  alarm 

system,  the  lock  is  disabled  from  opening,  and  any 
command functions are disabled. 

An  alarm  box,  sold  separately,  is  required  to  interface 
with the alarm system. 

 

Time delay override 

User  9  is  able  to  override  time  delay.  This  feature  is 
intended  for  cash  carriers  who  may  require  immediate 
access to the safe. 

 

Dallas Key / eKey / Dual Token 

Users  must  insert  a  Dallas  key  into  the  reader  on  the 
keypad  in  addition  to  entering  their  code  to  open  the 
lock system. This feature requires eKeys which are sold 
separately. 

Reviews: