Manual programming 

 

LG 39E Multi User  

 

Factory Mode 

 (Pre-Setup-mode)  

The lock maybe mounted in the factory mode. It opens when 

pressing key “1” and it sends a silent alarm signal. 

The advantage is that there is only 1 version storage and an 

easy use during mounting. 

 

Exit the Factory-Mode 

Keep pressed the key “0” until the double signal (4-5 

seconds). Now the manager code is 555555.

 

 

Code length and program selection 

(6-9 digit code length is possible) 

The code length and program selection are made with the 

function “8” in a group of 2 digits. The first digit is the code 

length and the second one is the program number. 

Program 0 = Manager mode (operation with parallel code) 

Program 1 = Manager mode with delay override 

Program 2 = Operation with two codes 

Program 3 = Two code operation with delay override 

Program 4 = Manager mode with alarm 

Program 5 = Manager with alarm and with delay override 

Program 6 = Two code operation with alarm 

Program 7 = Two code operation, alarm and delay override 

 

Programming 

(function 8) 

Enter the manager code “555555” and keep pressed the 

last number

 until the double signal is repeated (LED is on) 

and

 enter “8”.

  Enter  the group of  2-digits (code  length  and 

program  number)  double  signal  and  repeat  the  group  for 

confirmation (double signal).

 

In case of the 7-digit codes the manager code is 7x “5”. 

 

Install (Enable) user 

(function 1) 

Enter manager-code and keep last digit pushed until LED 

stays on. Press „1“ (double signal) and enter user-ID Nr. f.i. 

„1“ (double signal). Enter user code (double signal) and to 

confirm, enter the code again. Double signal and LED 

extinguished. 

In case a

 

new code

 

is not

 

accepted (3-time-signal),

 

this code 

is too similar to an already existing code. Select new code

NOTE: Users who are not installed in this stage will be 

blocked after changing the manager code! 

 

 Program “freeze” 

After changing the manager code the program is „frozen“ and 

the program settings can only be changed after a reset to 

Factory Mode. 

 

Reset to Factory Mode 

In case the manger code is lost or the setting of the lock has 

to be changed, a reset can be executed by means of the 

RESET-BOX (PN#6066). Unplug battery from the lock or 

entry. 

Push the "0" button for ca. 3 minutes (or leave it for 

10minuts powerless) and plug the RESET-BOX in the BAT-

connection of the lock. Wait until a longer signal. (0,5 sec) 

The Reset-Box requires a connected 9V-DURACELL 

ALKALINE-battery. 

The lock is in FACTORY MODE.

 

Disconnect Reset-Box and 

plug battery back again. Lock opens with “1”. 

 

Safety notice:

 Do not assign code to the users of no use for the time being. 

                        Remove the codes. (Function 3 and user number) 

 

 

 