background image

 

             

 

 

Kantooradres: 

Postadres: 

 

 

Vlijtstraat 40  

Postbus 127 

 

 

NL-7005 BN Doetinchem

 

NL-7000 AC 

 

H.R. te Arnhem nr: 09087869

 

Tel:  (+31)  314 376 876 

 

E-mail: [email protected] 

Internet: http://www.lagard.nl 

BTW nr: NL 8038.72.987.B01 

Fax: (+31)  314 376 878

 

 

LG 39E Combogard EN 

Revise: 1

 

 

Datum: 16-02-05

 

 

LA GARD Locks BV

 

 

Silent alarm: 

(must be programmed)

 

If feature is active AND optional alarm box or SP-box is connected.  

If the last digit is chosen one higher (+1) when entering the code, the lock 

will open as usual (double signal), but at the same time the alarm box is 

activated. Example: Combination: 471147  

Alarm code: 471148 

 

Time delay for opening: 

(Must be programmed) 

 

 

 

 

 

 

 

 

 

 

Time delay override: 

(Must be programmed)

 

If feature is active:

  

After entering a valid code (double signal) the delay period starts, the LED 

flashes red each 2-second interval. 

At the end of the delay period the Open window starts, the LED flashes 

each second and the lock beeps every 2 seconds. 

To open the lock, a valid code has to be entered during the Open window. 

If the Open window expires without the lock being opened, then the lock is 

secured again with the Time delay. 

Delete current delay time: press key “0” 

Extend current delay times: enter valid code. The delay period will start 

again. 

 

The  user  ID#  9  (money  carrier)  can  open  immediately.  At  the  operation 

with two codes the ID# 9 is entered as the second code. 

 

Power supply: 

When the batteries are running low, the lock will signal for about 3 

seconds while being opened. The batteries then have to be changed. 

Use 

DURACELL ALKALINE 

batteries only! 

The codes are stored in the lock also without power supply. 

 

3710, 3750 and 3750K

: Battery compartment is in the bottom of the entry. 

3035

: Open battery box (inside door) and insert new batteries. 

If the batteries have not been changed in time and the tension does not 

suffice to cancel the lock‘s blocking feature, a new 9V 

DURACELL 

ALKALINE

 battery can be pressed onto the contacts on the entry, until 

the code has been entered and the entry is rotated. 

When Time Delay is programmed, use a battery clip (on general sale). 

Black upper position, red lower position. 

 

When connected to the alarm equipment through the interlock device “SP“ 

then the power supply is secured from this place

.

 

 

Safety notice: 

• 

Change the manager code immediately 

• 

Do not use personal data (birth date) as a code  

• 

Keep the code from unauthorised use 

 

LED and acoustic signals: 

 

1 x short signal 

enter confirmation 

2 x short signal 

valid code entered 

3 x short signal 

wrong code, not accepted 

6 x short signal 

remote disable, blocked by the alarm 

equipment 

LED signal each 10sec. 1 flashing  blocking time after a wrong tries 

LED signal each 2sec. 

Time delay before opening is running 

Alternate LED and acoustic signals  Time window for opening is running 

 

A series of triple signals, ca. 3seconds: 

Low battery 

 

Still possible ca. 10 openings. 

 

According to the battery capacity there may be also less signals 

therefore the battery change should be made also in case of 

double signals 

 

 

Use 9V DURACELL ALKALINE batteries only! 

 

Get other manuals https://www.bkmanuals.com

Reviews: