background image

 
 

11

2)  Wait overnight for signal. 
3)  Be sure the projection alarm is at least 6 feet from any electrical 

devices, i.e. TV sets, computers, or other radio controlled clocks. 

4)  Remove batteries for five minutes, reinsert and leave the unit alone 

overnight without pressing buttons. 

5)  If problems persist contact La Crosse Technology. 

Problem: 

Hour is incorrect (minute is correct). 

Solution: 

Be sure correct time zone and daylight saving time are selected. 

 

Note: For any questions not answered, contact La Crosse Technology with the contact information 
found at the end of this instructional manual. 
 

VII. 

SPECIFICATIONS FOR WT-5360 

Temperature:

 

Measuring range: 

32

°

F to 99.9

°

F(0°C to +49.9°C) with 0.2

°

F(0.1°C) 

resolution.  

NOTE

“OFL”

 will display when 

temperature is out of this range. 

Checking intervals: 

Every 10 seconds 

Power source:

 

AC Adapter (included) 

Input: 120VAC/60Hz Output: DC 6V/100MA 

Battery type: 

2 x AA, 1.5V (alkaline recommended) (optional) 

Battery life: 

Approximately 12 months, depending on projection 
and backlight use 

Dimensions (L x D x H): 

 

Projection Alarm Clock 

4.6”L x 3.67”D x 2”H 
(116.7L x 51.3D x 93.1H mm) 

 

WARRANTY INFORMATION 

La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing 
defects in materials and workmanship. 
 
This limited warranty begins on the original date of purchase, is valid only on products purchased and 
used in North America and only to the original purchaser of this product.  To receive warranty service, 
the purchaser must contact La Crosse Technology, Ltd for problem determination and service 
procedures.  Warranty service can only be performed by a La Crosse Technology, Ltd authorized 
service center.  The original dated bill of sale must be presented upon request as proof of purchase to 
La Crosse Technology, Ltd or La Crosse Technology, Ltd’s authorized service center. 
 
La Crosse Technology, Ltd will repair or replace this product, at our option and at no charge as 
stipulated herein, with new or reconditioned parts or products if found to be defective during the 
limited warranty period specified above.  All replaced parts and products become the property of La 
Crosse Technology, Ltd and must be returned to La Crosse Technology, Ltd.  Replacement parts and 
products assume the remaining original warranty, or ninety (90) days, whichever is longer.  La Crosse 
Technology, Ltd will pay all expenses for labor and materials for all repairs covered by this warranty.  
If necessary repairs are not covered by this warranty, or if a product is examined which is not in need 
or repair, you will be charged for the repairs or examination.  The owner must pay any shipping 
charges incurred in getting your La Crosse Technology, Ltd product to a La Crosse Technology, Ltd 

Summary of Contents for WT-5360U

Page 1: ...WT 5360U 433 MHz Radio Controlled Alarm Clock With Projection Time Instruction Manual...

Page 2: ...ons 6 Time Zone Setting 6 7 Manual Time Setting 7 Year and Date Setting 7 12 24 Hour Clock Setting 8 Indoor Temperature Setting 8 Daylight Saving Time DST Setting 8 FEATURES OPERATIONS Features 8 Radi...

Page 3: ...me and frequency services for United States clientele WWVB The WWVB is an AM radio station in Ft Collins Colorado managed by the NIST The WWVB s function is to broadcast time of day information derive...

Page 4: ...receive the signal faster 3 Install the batteries in the projection alarm clock 4 DO NOT PRESS ANY BUTTONS FOR 15 MINUTES NOTE It is important to not press any buttons after inserting batteries as thi...

Page 5: ...e colon no tower icon will appear if the WWVB is too weak to be detected and the time display will start from 12 00 AM While the WWVB search is being conducted various numbers will appear in the time...

Page 6: ...r Setting 4 Calendar Display 5 Time Display in 12 24 hour Mode 6 Indoor Temperature Display 7 Daylight Saving Time On Off B FUNCTION BUTTONS There are 4 function buttons located on the front of the pr...

Page 7: ...ashing at the bottom of the LCD 2 Press the SNOOZE bar 2 times to advance to the year setting Press and release the MODE MIN button to advance to the appropriate year 3 Press and release the SNOOZE ba...

Page 8: ...ETTING Note The DST default is On meaning that the WWVB will automatically change the time according to Daylight Saving Time in the spring and fall For areas that do not recognize DST changes Arizona...

Page 9: ...ight designed for night viewing This will light up for 2 seconds whenever a button is pressed 2 The LED light cannot be turned on constantly this would drain the batteries and burn out the light E IND...

Page 10: ...he seconds appear V MAINTENANCE CARE A Avoid extreme temperatures vibrations and shock to prevent damage to the units B Clean displays and units with a soft damp cloth Do not use solvents or scouring...

Page 11: ...This limited warranty begins on the original date of purchase is valid only on products purchased and used in North America and only to the original purchaser of this product To receive warranty servi...

Page 12: ...This warranty covers only actual defects within the product itself and does not cover the cost of installation or removal from a fixed installation normal set up or adjustments claims based on misrep...

Page 13: ...erference received including interference that may cause undesired operation La Crosse Technology Made in China WT 5360 FCC ID OMO 01RX Receiver THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPER...

Reviews: