Astra-Z-4545
Wireless Manual Fire Alarm Call Point
Operation Manual
This operation manual is intended for studying the operating
principles, proper use, storage, and maintenance of the
Wireless Manual Fire Alarm Call Point Astra-Z-4545
(hereinafter referred to as a detector) (Figure 1).
List of Abbreviations
:
Astra-Zitadel System
: Astra-Zitadel on-site Wireless Intrusion
/ Fire Detection and Alarming System;
Astra-Zitadel System Control Panel
: Astra-Z-812M, Astra-Z-
8945 ver.A, Astra-8945 Pro or Astra-812 Pro Control Panel
(with connected Astra-Z Wireless Extender);
LT
: Astra-942 Laser Tester;
MSS Astra-Z
: Astra-Z Monitoring Software Suite;
MSS Astra Pro
: Astra Pro Monitoring Software Suite.
1 Function
1.1
The detector is designed for manual
activation of a fire alarm by pressing the
driving
element,
forming
«Fire»
notifications, and transmitting them to the
Astra-Zitadel System Control Panel via
radio.
1.2
Power is supplied to the detector
from one or two lithium-thionyl-chloride
batteries (primary and secondary), size
AA, voltage 3.6 V.
2 Operating Principle
The detector is activated by pressing the actuator
– indestruct-
ible plate. After being pressed the plate locks in the pushed
position.
Microprocessor forms «Fire» notification in accor-
dance with pre-set algorithm.
The detector is returned to standby mode by returning the
actuator to an initial state with a key-pusher.
3
Specification
Technical Parameters of Radio Channel
Operating frequency range, MHz .................. 2 400 to 2 483. 5
Number of operating channels at 5 MHz intervals ................ 16
Channel width, MHz ............................................................... 2
Wireless coverage range, line-of-sight, m, min ................... 300
General Technical Parameters
Current consumption, mA, max:
- with radio module OFF .................................................... 0.04
- with radio module ON ....................................................... 105
Battery replacement
indication threshold, V ......................................................... 2.6
Power supply voltage lower threshold (programmed
deactivation threshold retaining
battery discharge indication), V ........................................... 2.1
Overall dimensions, mm, max ................................. 110x94x47
Weight (without battery), kg, max ...................................... 0.17
Primary battery average lifetime, years, min .......................... 3
Secondary batteries set
average lifetime, years, min .................................................... 5
Operating Conditions
Temperature range,
°
C ................................ from -30 up to +55
Relative air humidity, % ............................... up to 93 at +40
°
C
without moisture condensation
4
Delivery Set
Astra-Z-4545 ................................................................... 1 pcs.
Mortise key (large) ........................................................... 1 pcs.
Key-pusher (small) .......................................................... 1 pcs.
Battery ............................................................................. 2 pcs.
Screw
3.9×32 .................................................................. 2 pcs.
Dowel 6×30 ..................................................................... 2 pcs.
Operation Manual ........................................................... 1 copy
5
Structure
5.1
The detector is designed as a block consisting of a
removable cover and a base, made of high-impact plastic
(Figure 2).
Figure 2
5.2
Mounted inside the cover is a printed circuit board (PCB)
with radio elements and slots for the primary and secondary
batteries. The recessed part of the cover also contains an
actuator with an inscription that clearly marks the place and
direction to be pressed
5.3
The upper section of the recessed part contains white or
yellow shutter, which emerges when the actuator is pressed.
5.4
Mounted on PCB is a tamper switch (S1button), which
results in the
«Tampering» notification when the cover is
removed.
5.5
Mounted on PCB are LEDs for the detector
’s operability
supervision.
6
Notifications
Table 1: Notifications processed by LEDs and Control Panel (or
MSS interface)
Notification
Type
Red
LED
White
LED
Control
Panel
Standby
mode start
Lights up
one
time
for
1 to
40
seconds
after detector
powering up
Not lit
−
Normal
Blinks
one
time
per
(60±5)
seconds
for
0,2 seconds
Not lit
+
Fire
Lights up
one time
for
10 seconds
Not lit
+
Tampering
Lights up
one
time
for
0.2
seconds
Not lit
+
Powering up
Not lit
Any
+
Primary battery
failure
Not lit
Any
+
Secondary
battery failure*
Not lit
Any
+
Power failure
Triple
blink
every
25
seconds
Not lit
+
Base removed
Figure 1