RESETTING THE MINIMUM AND MAXIMUM READINGS: 

User may reset the minimum and maximum temperature and humidity data to the current 
value by the following step: 
1. 

Press and hold the min/max/+ key for about 3 seconds to reset all the minimum/ 
maximum data of all channels and the indoor sensor to the current values in a 
single action. 

 

THERMO-HYGRO TRANSMITTER: 

The outdoor temperature and humidity are measured and transmitted every 16 seconds. 
The range of the Thermo-Hygro transmitter may be affected by the temperature. At cold 
temperatures the transmitting distance may be decreased. Please bear this in mind when 
placing the transmitter. 

Summary of Contents for WS9123IT

Page 1: ...fore operating INTRODUCTION Congratulations on purchasing this tiny 915MHz Temperature and Humidity Weather Station which displays the time indoor temperature and up to three outdoor temperatures and...

Page 2: ...ate of the art new wireless transmission technology exclusively designed and developed by LA CROSSE TECHNOLOGY IT offers you an immediate update of all your outdoor data measured from the transmitters...

Page 3: ...3 FEATURES The Temperature Station LCD Display Function Keys Hanging Hole Battery compartment cover Removable stand...

Page 4: ...outdoor temperature reading in degree Celsius C or Fahrenheit F Outdoor humidity reading in RH Can receive up to three outdoor transmitters Minimum and Maximum records of indoor temperature outdoor te...

Page 5: ...on of outdoor temperature and humidity to Temperature Station by 915 MHz signals Displays alternately the measured temperature and humidity readings on LCD Shower proof casing Wall mounting case Mount...

Page 6: ...ature station below Once the batteries are in place all segments of the LCD will light up briefly Following the indoor temperature and the time as 12 00 will be displayed If they are not shown in LCD...

Page 7: ...on of the Temperature Station and the transmitter see notes on Positioning and 915 MHz Reception When more than one transmitter is to be used 1 User shall remove all the batteries from the temperature...

Page 8: ...then be displayed on the Temperature station Also the signal reception icon will be displayed If this does not happen after 2 minutes the batteries will need to be removed from both units and reset f...

Page 9: ...the third transmitter as soon as the channel 2 icon and outdoor data are displayed on the temperature station Then within 2 minutes the channel 3 outdoor data from the third transmitter will be displa...

Page 10: ...AA IEC LR3 1 5V batteries When batteries need to be replaced the low battery icon will appear on the LCD To install and replace the batteries please follow the steps below 1 Lift up the battery compar...

Page 11: ...he LCD of the Temperature Station To install and replace the batteries please follow the steps below 1 Unload the battery holder at the bottom of the transmitter 2 Insert the battery observing the cor...

Page 12: ...e Temperature Station in the first few minutes of power supplying BATTERY CHANGE It is recommended to replace the batteries in all units at least every 12 months to ensure optimum accuracy of these un...

Page 13: ...ON KEYS Temperature Station The Temperature Station has only two easy to use function keys Set ch key Setting Channel Press and hold for about 3 seconds to enter the Manual setting mode min max key Se...

Page 14: ...f different outdoor transmitters channel 1 2 and 3 when more than 1 transmitter is used min max key Min Max temperature Used to toggle between the minimum and maximum recorded readings of indoor outdo...

Page 15: ...AND SETTINGS Receiver Low battery indicator Transmitter identification channel No Transmitter Low battery indicator Outdoor Reception Signal icon Outdoor Temperature in C Indoor Temperature in C Outdo...

Page 16: ...easily see whether the last reception was successful icon on or not icon off On the other hand the flashing of the icon shows that a reception is being done now For better distinctness the LCD screen...

Page 17: ...TURE UNIT C F SETTING User may choose to display the time in 12 hour or 24 hour mode Note When the time display is set as 12 hour mode the temperature unit will be fixed to F when the time mode is in...

Page 18: ...shall manually set the time of Temperature Station by the following steps 1 The hour digit of the time display will be flashing 2 Press the min max key to adjust the hour Press set key to confirm and...

Page 19: ...of the indoor or outdoor channels by the following steps 1 In normal display press set ch key to choose the desired channel transmitter 2 Press the min max key once to view the minimum indoor tempera...

Page 20: ...20 3 Press the min max key once more to view the maximum indoor temperature maximum outdoor temperature and maximum outdoor humidity of the selected channel Maximum icon Selected channel No...

Page 21: ...eset all the minimum maximum data of all channels and the indoor sensor to the current values in a single action THERMO HYGRO TRANSMITTER The outdoor temperature and humidity are measured and transmit...

Page 22: ...ing signal please check the following points 1 The distance of the Temperature Station or transmitter should be at least 1 5 to 2 metres away from any interfering sources such as computer monitors or...

Page 23: ...spring free from the contacts and force a false reset Should this happen accidentally then reset all units see Setting up above otherwise transmission problems may occur The transmission range is abou...

Page 24: ...Temperature Station comes with detachable stand which provides the option of table standing the unit in addition to wall mounting Before wall mounting please check that the outdoor temperature values...

Page 25: ...ll mount 1 Fix a screw not supplied into the desired wall leaving the head extended out by about 5mm 2 Hang the Temperature Station onto the screw Remember to ensure that it locks into place before re...

Page 26: ...26 POSITIONING THE REMOTE TEMPERATURE TRANSMITTER The remote temperature transmitter can be placed onto any flat surface or wall mounted using the bracket which doubles as a stand or wall mount base...

Page 27: ...27 To wall mount 1 Secure the bracket onto a desired wall using the screws and plastic anchors 2 Clip the remote temperature transmitter onto the bracket...

Page 28: ...any position where a large metal or highly polished surface is in the immediate vicinity garage doors double glazing etc Before securing in place please ensure that the Temperature Station can receiv...

Page 29: ...id leakage and damage Replace only with new batteries of the recommended type Do not make any repair attempts to the unit Return them to their original point of purchase for repair by a qualified engi...

Page 30: ...9 C with 0 1 C resolution OFL displayed if outside this range Outdoor Humidity measurement 1 to 99 Displays 1 when 1 displays 99 when 99 Indoor Temperature checking interval every 15 seconds Outdoor...

Page 31: ...Dimensions L x W x H Temperature Station 58 2 x 17 6 x 118 4 mm Outdoor Temperature Transmitter 36 6 x 13 5 x 87 9 mm LIABILITY DISCLAIMER Please ensure that all discarded packaging and unwanted elect...

Page 32: ...ct readings and any consequences that occur should an inaccurate reading take place This product is designed for use in the home only as indication of the temperature and other weather data This produ...

Page 33: ...iod of 12 months from date of purchase against failure to operate correctly to its listed specifications due to any manufacturing defects Distributed by Sontax Australia Phone 1800 653 238 Email sales...