background image

 

 

SETUP 

 

WHEN ONE TRANSMITTER IS USED 

1. 

First, insert the batteries in the transmitter (see “

How to install and 

replace batteries in the Thermo-hygro outdoor transmitter

 

on 

page 11). 

2. 

Within 2 minutes of powering up the transmitter, insert the batteries 
in the Weather Station (see “

How to install and replace batteries 

in the Weather Station

 

on pages 11-12). Once the batteries are 

in place, all segments of the LCD will light up briefly and a short 
signal tone will sound. Following the indoor temperature/humidity 
and the time, as 12:00 will be displayed. If this information is not 
displayed on the LCD after 60 seconds, remove the batteries and 
wait for at least 60 seconds before reinserting them. Once the 
indoor data is displayed user may proceed to the next step. 

3. 

After the batteries are inserted, the Weather station will start 
receiving data signal from the transmitter. The outdoor temperature 
and humidity data should then be displayed on

 

the Weather station. 

If this does not happen after 2 minutes, the batteries will need to be 
removed from both units and reset from step 1. 

4. 

The distance between the Weather Station and the transmitter 

 

should not be more than 300 feet  to ensure sufficient 915 MHz 
transmission. (see notes on “

Positioning” and “915 MHz 

Reception

”).  

 

Note: 

In the event of changing batteries of the units, ensure the batteries 

do not spring free from the contacts. Always wait at least 1 minute after 
removing the batteries before reinserting, otherwise start up and 
transmission problems may occur. 

 

WHEN MORE THAN ONE TRANSMITTER IS USED 

 

1. 

User shall remove all the batteries from the Weather Station and 
transmitters, and wait 60 seconds. 

2. 

Insert the batteries in the first transmitter. 

3. 

Within 2 minutes of powering up the first transmitter, insert the 
batteries in the Weather Station. Once the batteries are in

 

place, all 

segments of the LCD will light up briefly and a short signal tine will 
sound. Following the indoor temperature/humidity and the time as 
12:00 will be displayed. If this information is not displayed on the 
LCD after 60 seconds, remove the batteries from both units and 
wait for at least 60 seconds before reinserting them. 

 

 

4. 

The outdoor temperature and humidity data from the first 
transmitter (channel 1) and the signal reception icon   should be 
displayed on the Weather Station. If this does not happen after 2 
minutes, the batteries will need to be removed from both units and 
reset from step 1. 

5. 

Insert the batteries in the second transmitter as soon as the signal 
reception icon   and outdoor data are displayed on the Weather 
Station. Then within 2 minutes, the channel 2 outdoor data from the 
second transmitter and the "channel 2" icon should be displayed on 
the Weather Station. If this does not happen after 2 minutes, the 
batteries will need to be removed from all the units and reset from 
step 1.  

Note :

  User shall insert the batteries into the second transmitter 

within 45 seconds after the Weather Station displays the 
information of the first transmitter. 

6. 

Insert the batteries in the third transmitter as soon as the "channel 
2" icon and outdoor data are displayed on the Weather Station. 
Then within 2 minutes, the channel 3 outdoor data from the third 
transmitter will be displayed and the channel icon will shift back to 
"1" once the third transmitter is successfully received. If this is not 
happen, user shall restart the setting up from step 1. 

 

Note :

 User shall insert the batteries into the third transmitter within 

45 seconds after the Weather Station displays the information of 
the first transmitter. Or immediately after reception of the second 
transmitter is finished. 

7. 

The distance between the Weather Station and the transmitter 
should not be more than 300 feet to ensure sufficient 915 MHz 
transmission. (see notes on “

Positioning” and “915 MHz 

Reception

”).  

 

IMPORTANT:  

Transmission problems will arise if the setting for additional sensors is not 
followed as described above. Should transmission problems occur, it is 
necessary to remove the batteries from all units and start again the set-up 
from step 1. 

 

Notes: 

 

If the signal reception is not successful on the first frequency of 
915MHz for 45 seconds, the frequency is changed to 920MHz and 
the learning is tried for another 45 seconds. If it is still not 
successful the reception is tried for 45 seconds on 910MHz. This 
will also be done during re-synchronization.

 

Summary of Contents for WS-9057U

Page 1: ...setting mode Alarm setting with snooze function Display 12 Moon phases throughout the year Weather forecasting with weather tendency indicator Indoor comfort indicator Temperature display in F C Indoo...

Page 2: ...ries from both units and wait for at least 60 seconds before reinserting them 7 4 The outdoor temperature and humidity data from the first transmitter channel 1 and the signal reception icon should be...

Page 3: ...ation of the environment Return used batteries to an authorized depot DEVICE RESET The Weather Station and the Thermo hygro transmitter need to be reset when one of the following conditions occur Unsu...

Page 4: ...he alarm hour inside alarm setting mode Decrease relative pressure value within manual set mode Stop the alarm during alarm ringing Stop snooze mode 15 OUT key Press shortly to toggle between MAX MIN...

Page 5: ...ey and enter in the Time Zone setting TIME ZONE SETTING Flashing Last digit flashing 19 The time zone default of the Weather Station is 5h U S time zones are negative numbers 5h EST 6h CST 7h MST and...

Page 6: ...e following hour CALENDAR SETTING Year 23 Note When set to 24 hour time the calendar setting mode will display the date to the left of the month The date default of the Weather station is 1 1 2006 Onc...

Page 7: ...ET key and exit the Manual settings Flashing 27 TO EXIT THE MANUAL SETTING MODE To exit the manual setting mode anytime during the manual setting press the SNOOZE CH key or wait for automatic timeout...

Page 8: ...third section of LCD can be displayed in any of the following combinations Sunny Cloudy with sunny intervals Rainy For every sudden or significant change in the air pressure the weather icons will upd...

Page 9: ...s scale is equal to the current pressure and each change 2 4 6 represents how high or low in hPa the past pressure was compared to the current pressure Air pressure over the last 24 hours 35 If the ba...

Page 10: ...the 915MHz signal frequency may prevent correct signal transmission or reception Neighbors using electrical devices operating on the 915MHz signal frequency can also cause interference Note When the 9...

Page 11: ...to 59 9 C with 0 1 C resolution OF L displayed if outside this range 43 Outdoor 39 8 F to 139 8 F with 0 2 F resolution 39 9 C to 59 9 C with 0 1 C resolution OF L displayed if outside this range Indo...

Page 12: ...service center 6 units used for other than home use 7 applications and uses that this product was not intended or 8 the products inability to receive a signal due to any source of interference This w...

Reviews: