![La Crosse Technology WS-2315AL Operation Manual Download Page 17](http://html.mh-extra.com/html/la-crosse-technology/ws-2315al/ws-2315al_operation-manual_666381017.webp)
20.
Transmission Range
The transmission distance from the thermo-hygro sensor to the base station in
open space under optimum conditions is 100ft. Although the signal transmis-
sion may travel though solid surfaces or objects, the following points should be
avoided if possible:
•
High frequency interferences of any kind.
•
High densities of trees.
•
Broadband interferences in municipal areas can reach levels reducing the
signal/noise ratio over the entire frequency band, thus also reducing the
transmission distance.
•
Devices working close by (example a neighbor’s house) may also influ-
ence reception.
•
Poorly shielded PCs can cause interferences that will reduce or in some
cases stop reception
•
The sensor and receiver should not be mounted on metal surfaces as this
will reduce transmission range.
21.
Cleaning and Maintenance
•
Clean the housing and screen of the base station only with a soft damp
cloth. Do not use abrasives or solvents.
•
Ensure that the rain sensor does not collect leaves or other dirt by check-
ing the funnel for blockages every now and then. Also clean the seesaw
of the sensor with a damp cloth and check by lightly tapping with your fin-
ger that it can move freely from side to side.
•
Do
not
clean the funnel with the bottom half of the rain sensor attached
nor the bottom part itself under running water. This may bear the danger
of water entering the unit’s inner parts and cause damages.
•
Do not immerse the base station in water.
•
Should there be damage to this product, please do not attempt to make
any repairs. Please take this unit to a qualified technician. Opening or
improper handling of the units will invalidate any guarantee.
22. Specifications
Outdoor data
Transmission Distance in Open Field
:
100ft max.
Temperature Range
:
-
21.8°F to +157.8°F (show OFL”
if outside range)
Resolution :
0.2°F
Measuring Range Rel. Humidity
:
20% to 95% (if the relative hu-
midity is less than 20% or
greater than 95%, it will display
19% or 96%)
Rain Volume Display
:
0 to 39.37 inches (1h and 24h
rainfall)
0 to 98.38 inches (Total rainfall)
Resolution :
0.1mm
Wind Speed
:
0 to 111.8 mph
Resolution :
0.1
mph
Wind Direction
:
Graphic Resolution 22.5 De-
grees, Numerical Resolution,
Letter format
Using 433MHz wireless data transmission:
Measuring interval
thermo-hygro sensor
:
32 sec (if wind factor>22.36
mph) or 128sec (if wind factor
< 22.36mph) 10 minutes (if the
base station fails to receive any
data after 5 attempts in a row, all
outdoor data readings will dis-
play “---“, except for the rain
value)
With cable connection for data transmission:
Measuring interval
thermo-hygro sensor
: 8 seconds
Indoor data
Pressure/ temperature
:
4 times per minute
Indoor Temperature Range
:
14.1°F to + 139.8°F (shows
“OFL” if outside range)
Resolution :
0.2°F
Measuring Range Rel. Humidity
:
20% to 95% (if the relative hu-
midity is less than 20% or
greater than 95%, it will display
19% or 96%)