Pressure high alarm and low alarm setting 

1)  Press the ALARM key to enter the normal time alarm 
2)  Continue to press the ALARM key until you reach the pressure high alarm 

set mode 

3)  Press and hold the SET key to enter the pressure setting values (digits will 

start flashing) and set the desired pressure high by using the PLUS (+) or 
MINUS (-) keys 

4)  Press ALARM key to confirm and press the MIN/MAX key to return to the 

normal display mode or press the ALARM key once more to toggle to the 
pressure low alarm set mode. 

5)  Press and hold the SET key to enter the pressure low setting values (digits 

will start flashing) and set the desired pressure low by using the PLUS (+) 
or MINUS (-) keys 

6)  Press ALARM key to confirm and press the MIN/MAX key to return to the 

normal display mode or press the ALARM once more to toggle to another 
alarm setting mode. 

 

Wind speed high alarm and low alarm setting 

1)  Press the ALARM key to enter the normal time alarm 
2)  Continue to press the ALARM key until you reach the wind speed high 

alarm set mode 

3)  Press and hold the SET key to enter the wind speed setting values (digits 

will start flashing) and set the desired wind speed high by using the PLUS 
(+) or MINUS (-) keys 

4)  Press ALARM key to confirm and press the MIN/MAX key to return to the 

normal display mode or press the ALARM key once more to toggle to the 
wind speed low alarm set mode. 

5)  Press and hold the SET key to enter the wind speed low setting values 

(digits will start flashing) and set the desired pressure low by using the 
PLUS (+) or MINUS (-) keys 

6)  Press ALARM key to confirm and press the MIN/MAX key to return the 

normal display mode or press the ALARM once more to toggle to another 
alarm setting mode. 

 

Wind direction alarm setting 

1)  Press the ALARM key to enter the normal time alarm 
2)  Continue to press the ALARM key until you reach the wind direction alarm 

set mode 

3)  Press and hold the SET key to enter the wind direction setting values. 
4)  Using the PLUS (+) or MINUS (-) keys select the desired wind direction 

and use the SET key to confirm or cancel each direction input 

5)  Press ALARM key to confirm and press the MIN/MAX key to return the 

normal display mode or press the ALARM once more to toggle to another 
alarm setting mode. 

 

Storm warning alarm setting 

Unlike the other weather alarms, the storm warning alarm is set by entering 
the main manual setting mode as follows: 
1)  Press the SET key to enter the manual setting mode 
2)  Continue to press the SET key until the Storm warning icon flashes (ten-

dency arrow flashing downwards with the pressure values flashing) 

3)  Set the desired inHg pressure value (9, 12, 15, 18, 21, 24, 27 inHg) using 

the PLUS (+) or MINUS (-) keys 

4)  Press the MIN/MAX key to confirm and return to the normal display. 
 

Storm warning alarm ON/OFF 

After storm warning alarm setting, the next mode to appear after pressing the 
SET key is the storm warning ON/OFF.  Use the PLUS (+) or MINUS (-) key to 
change the status to AON or AOFF. Default setting is ON: 
 
Should the air pressure drop equal or below the pre-set inHg value within the 
last 6 hour period, then the downward tendency arrow will flash as an indica-
tion of possible storm. The base station will take hourly measurements as a 
point of reference.  The storm-warning indicator will stop flashing once the air 
pressure becomes more stable. 
 

Master Alarm – BUZZER OFF 

The time and all the weather alarms may have buzzer sound set to OFF by 
holding the MINUS (-) key down for about 3 seconds in normal display mode 
and the BUZZER OFF icon appears on the bottom left of the LCD.  When the 
BUZZER OFF is displayed, the time and all other weather alarms when acti-
vated will only flash but not sound regardless if that particular alarm has been 
set to the ON. To deactivate the BUZZER OFF, press the MINUS (-) key once 
more. 
 

General Alarm Icon 

The general alarm icon on the bottom right corner of the LCD will appear when 
any weather alarm is activated to show the user that a set weather condition 
has been reached. The activated alarm can be determined by checking the set 
alarm values against the MIN/MAX values reached. To deactivate the general 
weather alarm icon, press the ALARM key. 

 
Important 

When entering the alarm set mode for a specific weather or temperature con-
dition, the corresponding alarm is automatically enabled (ON) when the SET 
key is pressed, regardless of its previous setting and the alarm value will flash 
to indicate that it has been activated.  Press the ALARM key to confirm the 
setting and continue pressing the ALARM key to toggle through each alarm 
mode until it returns to the normal display mode or press the MIN/MAX key at 
any time to exit the alarm setting modes. 

Summary of Contents for WS-2315AL

Page 1: ...ique features 2 Intended Use Weather Station The base station measures the indoor environment of its surrounding area and receives weather data from the following three outdoor sensors 1 Thermo Hygro Sensor 2 Wind Sensor 3 Rain Sensor The received data is continuously updated to bring you the latest weather information on the base station s LCD The outdoor thermo hygro sensor is the main data comm...

Page 2: ...s of Wind sensor The wind sensor measures wind speed and wind direction and sends the data to thermo hygro sensor which in turn transmits the data to the base station Operating power is taken from the thermo hygro sensor using a 32ft cable connection Features of Rain sensor The rain sensor measures the rainfall and sends the data to thermo hygro sensor which in turn transmits the data to the base ...

Page 3: ...to fix main unit to the mast holder Rain Sensor Main unit base and funnel 32ft cable already at tached to the main unit Heavy weather PC software CD Rom format English version only 6 5ft PC cable for PC connection optional use included 5 Setting up First choose to use the adaptor included in this set or batteries for operation Both these methods allow for operation using wireless 433MHz transmissi...

Page 4: ...ime the thermo hygro sensor is powered up for example after a change of batteries a random security code is transmitted and this code must be synchronized with the base station to receive weather data When the base station is powered up a short beep will sound and all LCD segments will light up for about 5 seconds before it enters into a 15 minute learning mode to learn the sensors security code A...

Page 5: ...a by simply disconnecting or connecting the cable from the base station to the sensor When the base station detects no cable connection to the sensors the base station will automatically change to using 433 MHz for reception of the weather data from the sensors The data receiving intervals are as follows Using cable connection data is updated every 8 seconds Using wireless 433 MHz data is updated ...

Page 6: ...TE The WWVB receiver is located in the base station Base Station With two foldable legs at the back of the unit the base station can be placed onto any flat surface or wall mounted at the desired location by the hanging holes also at the back of the unit It is important to check that the 433MHz if using wireless connection and the WWVB radio controlled time signal can be received before permanentl...

Page 7: ...g the thermo hygro Sensor An ideal mounting place for the thermo hygro sensor would be the outer wall beneath the extension of a roof as this will protect the sensor from direct sunlight and other extreme weather conditions To wall mount use the 2 screws to affix the wall bracket to the desired wall plug in the thermo hygro sensor to the bracket and secure both parts by the use of the supplied scr...

Page 8: ...86ºF high Outdoor temperature alarm 32ºF low 104ºF high Indoor humidity alarm 35 RH low 65 RH high Outdoor humidity alarm 45 RH low 70 RH high Wind chill alarm 50ºF low 86ºF high Dew point alarm 32ºF low 68ºF high Rainfall 24h alarm 1 96 inches Rainfall 1h alarm 0 03 inches Wind Speed 1 0 mph low 62 mph high Wind direction alarm None set Note All alarm default values are deactivated at the start u...

Page 9: ... the one value given by various newspapers TV and radio broad casting stations in their daily weather forecasts for their respective locations users can set the relative air pressure of the weather station to this value to represent readings your their area see Basic Programming Modes below Weather Data LCD Section 2 Indoor temperature and humidity are displayed simultaneously in this section Use ...

Page 10: ...tal WIND key To toggle between the following settings Wind speed Wind direction Wind direction display in degrees ALARM key In normal mode to enter the alarm programming mode In alarm programming mode to select the following setting modes Time alarm setting Indoor temperature alarm high low Outdoor temperature alarm high low Indoor humidity alarm high low Outdoor humidity alarm high low Outdoor wi...

Page 11: ...me If reception has been successful the received time and date will over write the manually set time and date and no further reception is at tempted until the following day 14 MIN MAX Programming Modes MIN MAX display Mode The MIN MAX Mode provides the user with information about the MIN MAX values of all weather data together with the time and date at which these values were recorded Entering eac...

Page 12: ...MI NUS keys 4 Press ALARM key to confirm followed by the MIN MAX key to return to the normal display mode Indoor temperature high alarm and low alarm setting 1 Press the ALARM key to enter the normal time alarm 2 Press the ALARM key again to enter indoor temperature high alarm set mode 3 Press and hold the SET key to enter the indoor temperature high setting values digits will start flashing and s...

Page 13: ...normal display mode or press the ALARM key once more to toggle to the wind chill low alarm set mode 5 Press and hold the SET key to enter the wind chill low setting values digits will start flashing and set the desired wind chill low by using the PLUS or MINUS keys 6 Press ALARM key to confirm and press the MIN MAX key to return the normal display mode or press the ALARM once more to toggle to ano...

Page 14: ... mode Storm warning alarm setting Unlike the other weather alarms the storm warning alarm is set by entering the main manual setting mode as follows 1 Press the SET key to enter the manual setting mode 2 Continue to press the SET key until the Storm warning icon flashes ten dency arrow flashing downwards with the pressure values flashing 3 Set the desired inHg pressure value 9 12 15 18 21 24 27 in...

Page 15: ...ctivated It has to drop to below 75 2 F with a pre set hysteresis of 1 8 F so that the alarm can be produced again Hysteresis values for the various weather data types are given in the following table Weather data Hysteresis Temperature 1 8 F Humidity 3 RH Air pressure 0 0295 inHg Rainfall 24h 0 1968 inch Rainfall 1h 0 01968 inch Wind 3 1 mph 16 Auto memory for stored values The base station has a...

Page 16: ...s Never dispose of batteries in a fire as this may cause explosion risk of fire or leakage of dangerous chemicals and fumes 19 Problems and interference with operation Problem cause Remedy Distance between sensors and receiver too long Reduce distance between sensors and receiver to receive signal High shielding materials between the units thick walls steel concrete isolating aluminum foil and etc...

Page 17: ...ing water This may bear the danger of water entering the unit s inner parts and cause damages Do not immerse the base station in water Should there be damage to this product please do not attempt to make any repairs Please take this unit to a qualified technician Opening or improper handling of the units will invalidate any guarantee 22 Specifications Outdoor data Transmission Distance in Open Fie...

Page 18: ...vered by this warranty or if a product is examined which is not in need or repair you will be charged for the repairs or examination The owner must pay any shipping charges incurred in getting your La Crosse Technology Ltd product to a La Crosse Technology Ltd authorized service center La Crosse Technology Ltd will pay ground return shipping charges to the owner of the product to a USA address onl...

Reviews: