Does the Clock Have a Backlight? 

 

  No, this Digital Atomic Clock does not have a backlight.   

  Generally, an a/c power cord is required for products to have a backlight. 

  This clock does not use a/c power cord. 

 

Dashes, OFL or Stuck Indoor Temperature 

 

  This is generally a power related issues.  

 

Batteries

 may be overpowered or underpowered. Remove batteries from Digital Atomic 

Clock.  

  Press any button 20 times. Leave the Digital Atomic Clock unpowered for 1-2 hours.  

  Insert fresh alkaline batteries with correct polarity.  

  If the indoor Temperature is still dashes or OFL, the Digital Atomic Clock may need 

replacement. 

 

Inaccurate Indoor Temperature Reading 

 

 

Side-by-side test

: Bring the outdoor transmitter in the house and place it next to the Digital 

Atomic Clock for 2 hours.  

  Compare indoor and outdoor Temperature. The temperature should be within 4 degrees to 

be within tolerance.  See the section on 

accuracy

 for details. 

  Look for heat sources such as sunlight, door or window frames, or reflected heat of cold. 

 

Time is off by hours 

 

  Check to see if the 

WWVB

 Tower icon appears on the Digital Atomic Clock. If not, the Digital 

Atomic Clock has not received a WWVB time signal in the past 24-hours.  

  Reposition the Digital Atomic Clock with the front or back facing Colorado. 

  Check that the 

Time Zone

 selected correctly reflects your location.  Adjust the time zone in 

the 

Program Menu

  Check that the DST indicator is correct for your location (most areas observe DST so this 

should be ON). Adjust the DST indicator in the 

Program Menu.

 

  Large buildings, metal roofed buildings and buildings or rooms full of electrical and/or radio 

equipment make it difficult to receive the WWVB time signal. 

 

Daylight Saving Time 

 

 

Dependent on your location, position of the clock in your home, and atmospheric 
interference, it may take up to 5 nights for the change from Daylight Savings Time to 
Standard Time and vice-versa to occur.

 

  Check for a 

WWVB

 Tower Icon showing on your Clock. The tower icon indicates you have 

received the WWVB signal from Ft Collins CO in the past 24-hours.  

  Check that the clock is in the correct 

Time Zone

.  

  Check whether the DST indicator is ON or OFF. If the indicator is OFF the clock will not 

change. 

  Check for fresh 

batteries

. Without proper batteries, the antenna will have a harder time 

picking up the signal.

 

  Position the Digital Atomic Clock in a window (

with the front or back

) facing Ft. Collins, 

Colorado and leave for up to five nights. If you do not have a window facing this direction, 
locate the Clock near an outside wall and point the unit in this general direction.  

 
 
 

Summary of Contents for 513-149V2

Page 1: ... Constantly 4 Inaccurate Outdoor Temperature Reading 4 Intermittent Outdoor Temperature 4 Outdoor Temperature is Stuck or OFL 4 Outdoor Transmitter Fell and No Longer Works 4 Outdoor Transmitter Drains Batteries Quickly 5 Temperature Trend Arrows 5 Mounting Positioning Outdoor Transmitter 5 Position Digital Atomic Clock 6 Distance Resistance Interference 6 Accuracy 7 Indoor Temperature 7 Outdoor T...

Page 2: ...ronment the batteries reside in for the 10 years can deplete the power Good name brand batteries make less noise which reduces the chance of RF radio frequency interference from the battery compartment A minimum voltage of 1 48V for each battery is necessary for proper performance Outdoor Transmitters Use Alkaline batteries or Lithium for temperatures below 20 F 28 8 C Indoor Displays Use Alkaline...

Page 3: ...n between the transmitter and the Digital Atomic Clock Check the position of the Digital Atomic Clock Turn the Digital Atomic Clock 90 degrees towards the outdoor transmitter for better reception Try the quick connect or factory restart Batteries often resolve the connection issue Dashes shown for Outdoor Temperature Dashes means the connection is lost between the Digital Atomic Clock and the outd...

Page 4: ...wn Move the outdoor transmitter to a closer location Freezer test Confirm the Digital Atomic Clock is reading the correct outdoor transmitter Place the transmitter in the freezer for an hour and watch the temperature drop on the Digital Atomic Clock Indoor distance test Please complete the Restart with transmitter and Digital Atomic Clock 5 10 feet apart and inside to establish a strong connection...

Page 5: ...flect the temperature change in the past three hours UP ARROW Temperature rising more than 2 F 1 C over the past three hours RIGHT ARROW Temperature did not change more than 2 F 1 C over the past three hours DOWN ARROW Temperature falling more than 2 F 1 C over the past three hours Mounting Positioning Outdoor Transmitter Mount outdoor Temperature transmitters vertically and under a bit of an over...

Page 6: ... mounting screws not included into a wall within transmission range of the outdoor transmitter leaving approximately 3 16 of an inch 5mm extended from the wall Place the Digital Atomic Clock onto the screws using the hanging holes on the backside Gently pull the Digital Atomic Clock down to lock the screws into place Note Always ensure that the Digital Atomic Clock locks onto the screws before rel...

Page 7: ...ct temperature as long as the LCD display continues to function Temperature Cycle 30 seconds Outdoor Temperature Measure range 40 to 158 0 to 70 Accuracy 1 degree Fahrenheit at room temperature 68F to 75F 20 to 24 Accuracy 2 degrees Fahrenheit 32 F to 122 F 0 to 50 Accuracy 4 degrees Fahrenheit otherwise Resolution 0 1 degree F Digital Atomic Clock How tall are the Time Numbers The time numbers ar...

Page 8: ...he past 24 hours Reposition the Digital Atomic Clock with the front or back facing Colorado Check that the Time Zone selected correctly reflects your location Adjust the time zone in the Program Menu Check that the DST indicator is correct for your location most areas observe DST so this should be ON Adjust the DST indicator in the Program Menu Large buildings metal roofed buildings and buildings ...

Page 9: ...is activated DEACTIVATE From the time mode press and release the ALARM button once to show Alarm Time With the Alarm time showing press and release the ALARM button to deactivate the alarm The alarm icon will disappear when alarm is deactivated Snooze Alarm When the alarm sounds press the SNOOZE button to trigger snooze alarm for 9 minutes The snooze icon Zz will flash when the snooze feature is a...

Page 10: ...e weekday will set automatically after the year month and date are set FAHRENHEIT CELSIUS Press and release the F C button to select temperature readings in Fahrenheit or Celsius No WWVB Tower Icon The Digital Atomic Clock has not received a WWVB time signal in the past 24 hours Position the Digital Atomic Clock for better reception Hold the TIME button to send the Digital Atomic Clock on a signal...

Page 11: ... displays This can make the Digital Atomic Clock display appear frozen With all power removed the Digital Atomic Clock should be blank If numbers still appear please check for scratch guard Check that the batteries are installed correctly This is generally a power related issue Batteries may be overpowered or underpowered Remove batteries from Digital Atomic Clock Press any button 20 times Leave t...

Reviews: