  An outdoor transmitter that has fallen into a puddle or other standing water or snow may 

have water damage.  

  Transmitters are water resistant, not waterproof. 

  A fall can shock the transmitter or the batteries in the transmitter.  

  Batteries that have fallen on a hard surface may be damaged and unable to function 

properly. 

  Complete a 

Restart

 with fresh batteries. 

  Use 

Batteries

 dated at least six years in advance of the current year. Batteries dated earlier 

than six years from now may still work, but may be unstable in performance. 
 

Outdoor Transmitter Drains Batteries Quickly 

 

  Test a new set of alkaline batteries. Write down the date of installation and the voltage of the 

batteries. 

  When the batteries fail, please note the date and voltage again. This is helpful in 

determining the problem. 

  Check the 

distance

 and resistance between the transmitter and Digital Atomic Clock. 

Transmitters at the end of the range may work while batteries are fresh but not after they 
drain a bit. 

  Check for leaking batteries, which may damage the transmitter. 

  Battery life is over 24 months when using reputable battery brands for both Alkaline and 

Lithium batteries. 

 

Temperature Trend Arrows 

 

  Black arrows next to the indoor and outdoor temperature readings reflect the temperature 

change in the past three hours. 

  UP ARROW: Temperature rising more than 2°F (1°C) over the past three hours

 

  RIGHT ARROW: Temperature did not change more than 2°F (1°C) over the past three 

hours 

 

  DOWN ARROW: Temperature falling more than 2°F (1°C) over the past three hours

 

 

Mounting/Positioning Outdoor Transmitter 

 

  Mount outdoor Temperature transmitters vertically and under a bit of an overhang.  

  Protect the outdoor transmitter from standing rain or snow, and from the overhead sun, 

which can cause it to read incorrectly. Generally, mounting under an eave or deck rail works 
well. 

  Construct a small roof or box for the transmitter if you do not have an overhang. Please be 

sure the box is well vented. 

  Mount the transmitter on the North side to prevent sun from causing incorrect readings.  

  Mount at least 6 feet in the air for a strong signal. 

  Outdoor transmitters are water resistant but not water proof.  

  Avoid more than one wall between the transmitter and the Digital Atomic Clock. 

  Do not mount near electrical wires, transmitting antennas or other items that wil

interfere

 

with the signal. 

  RF (radio frequency) signals do not travel well through moisture or dirt. 

  Place the outdoor transmitter and the Digital Atomic Clock in the desired shaded locations, 

and wait approximately 1-hour before permanently mounting the transmitter to ensure that 
there is proper reception.  

  Do not mount the transmitter on a metal fence. This significantly reduces the effective range. 

 
 
 

Summary of Contents for 513-149V2

Page 1: ... Constantly 4 Inaccurate Outdoor Temperature Reading 4 Intermittent Outdoor Temperature 4 Outdoor Temperature is Stuck or OFL 4 Outdoor Transmitter Fell and No Longer Works 4 Outdoor Transmitter Drains Batteries Quickly 5 Temperature Trend Arrows 5 Mounting Positioning Outdoor Transmitter 5 Position Digital Atomic Clock 6 Distance Resistance Interference 6 Accuracy 7 Indoor Temperature 7 Outdoor T...

Page 2: ...ronment the batteries reside in for the 10 years can deplete the power Good name brand batteries make less noise which reduces the chance of RF radio frequency interference from the battery compartment A minimum voltage of 1 48V for each battery is necessary for proper performance Outdoor Transmitters Use Alkaline batteries or Lithium for temperatures below 20 F 28 8 C Indoor Displays Use Alkaline...

Page 3: ...n between the transmitter and the Digital Atomic Clock Check the position of the Digital Atomic Clock Turn the Digital Atomic Clock 90 degrees towards the outdoor transmitter for better reception Try the quick connect or factory restart Batteries often resolve the connection issue Dashes shown for Outdoor Temperature Dashes means the connection is lost between the Digital Atomic Clock and the outd...

Page 4: ...wn Move the outdoor transmitter to a closer location Freezer test Confirm the Digital Atomic Clock is reading the correct outdoor transmitter Place the transmitter in the freezer for an hour and watch the temperature drop on the Digital Atomic Clock Indoor distance test Please complete the Restart with transmitter and Digital Atomic Clock 5 10 feet apart and inside to establish a strong connection...

Page 5: ...flect the temperature change in the past three hours UP ARROW Temperature rising more than 2 F 1 C over the past three hours RIGHT ARROW Temperature did not change more than 2 F 1 C over the past three hours DOWN ARROW Temperature falling more than 2 F 1 C over the past three hours Mounting Positioning Outdoor Transmitter Mount outdoor Temperature transmitters vertically and under a bit of an over...

Page 6: ... mounting screws not included into a wall within transmission range of the outdoor transmitter leaving approximately 3 16 of an inch 5mm extended from the wall Place the Digital Atomic Clock onto the screws using the hanging holes on the backside Gently pull the Digital Atomic Clock down to lock the screws into place Note Always ensure that the Digital Atomic Clock locks onto the screws before rel...

Page 7: ...ct temperature as long as the LCD display continues to function Temperature Cycle 30 seconds Outdoor Temperature Measure range 40 to 158 0 to 70 Accuracy 1 degree Fahrenheit at room temperature 68F to 75F 20 to 24 Accuracy 2 degrees Fahrenheit 32 F to 122 F 0 to 50 Accuracy 4 degrees Fahrenheit otherwise Resolution 0 1 degree F Digital Atomic Clock How tall are the Time Numbers The time numbers ar...

Page 8: ...he past 24 hours Reposition the Digital Atomic Clock with the front or back facing Colorado Check that the Time Zone selected correctly reflects your location Adjust the time zone in the Program Menu Check that the DST indicator is correct for your location most areas observe DST so this should be ON Adjust the DST indicator in the Program Menu Large buildings metal roofed buildings and buildings ...

Page 9: ...is activated DEACTIVATE From the time mode press and release the ALARM button once to show Alarm Time With the Alarm time showing press and release the ALARM button to deactivate the alarm The alarm icon will disappear when alarm is deactivated Snooze Alarm When the alarm sounds press the SNOOZE button to trigger snooze alarm for 9 minutes The snooze icon Zz will flash when the snooze feature is a...

Page 10: ...e weekday will set automatically after the year month and date are set FAHRENHEIT CELSIUS Press and release the F C button to select temperature readings in Fahrenheit or Celsius No WWVB Tower Icon The Digital Atomic Clock has not received a WWVB time signal in the past 24 hours Position the Digital Atomic Clock for better reception Hold the TIME button to send the Digital Atomic Clock on a signal...

Page 11: ... displays This can make the Digital Atomic Clock display appear frozen With all power removed the Digital Atomic Clock should be blank If numbers still appear please check for scratch guard Check that the batteries are installed correctly This is generally a power related issue Batteries may be overpowered or underpowered Remove batteries from Digital Atomic Clock Press any button 20 times Leave t...