background image

3

BASICS

Power Up

Note: After all parts have been powered on, the 
station will begin searching for your outdoor sensors. 
These should automatically connect within the next 10 
minutes. 

3.

Install the power cord into an 
outlet, and then into the back of 
the weather station. For backup, 
install 3 “AA” batteries into the 
Battery Compartment.

Note:

 

Power cord is required 

for constant backlight. Display 
will come on for 10 seconds at a 
time after a button push if only 
powered via batteries.

Bottom of Breeze Sensor

Model No. 

TX145WSDTHv3

Back of Station

Model No. 

328-1414

Initial Setup

1.

Remove the top 
Funnel and install 
2 “AA” batteries 
into your Rain 
Sensor’s Battery 
Compartment. 

Inside of Rain Sensor

Model No. 

TX145R

Install 3 “AA” batteries 
into your Breeze 
Sensor’s Battery 
Compartment.

2.

Summary of Contents for 328-1414

Page 1: ...SET UP GUIDE MODEL 328 1414 Wireless Professional Weather Station...

Page 2: ...nd Data Wind Speed Records Reset Wind Records Position the Breeze Sensor Included Mounting Accessories Basic Installation Advanced Installation 11 12 12 13 13 14 14 TEMPERATURE HUMIDITY Set Alerts Ale...

Page 3: ...AA batteries into the Battery Compartment Note Power cord is required for constant backlight Display will come on for 10 seconds at a time after a button push if only powered via batteries Bottom of B...

Page 4: ...change viewing 24 hour Rainfall data Pressure data or auto scroll between both options 2 WIND Press to view Wind Speed History While viewing hold the CLEAR button to delete the history reading Hold to...

Page 5: ...LCD Display Icons Pressure Rain Auto scroll Atomic Time Alerts Sensor Reception Breeze Sensor Temp Humidity Low Battery Wind Direction Prevailing Direction Add on Sensor Temp Humidity Auto Dim BASICS...

Page 6: ...H or KMH Wind Direction Letters or Degrees Rainfall Inches or Millimeters Weekday will set automatically after year month date settings are adjusted BASICS 1 Hold the SET button to enter the Settings...

Page 7: ...ur Rain to display Pressure 24 HOUR Rain Sensor Reception Auto scroll both readings Press the MODE button to toggle between Pressure and 24 hour Rain readings The Pressure or Rain icon will show to in...

Page 8: ...sappears Rain History 1 HOUR Last one hour rainfall Example current time is 6 49 1HR rain is accumulated total between 5 50 and 6 49 Updates every 5 minutes 24 HOURS A running total for the past 24 ho...

Page 9: ...searching and be solid once connected Positioning the Rain Sensor For Accurate Measurements Mount the Rain Sensor in an open area at least 3 feet above the ground for accurate rainfall readings Ensure...

Page 10: ...inside This Rain Sensor is designed for outdoor use and will withstand temperatures below freezing Cleaning Your Rain Sensor Leaves grass and other debris may need to be removed periodically from the...

Page 11: ...LING DIRECTION The top wind speed in the past 60 minutes The top wind speed in the past 31 seconds Choose between cardinal points letters or degrees in the Settings Menu Appears if a wind speed alert...

Page 12: ...nd speed records with time and date stamps The wind speed records include Past 24 hours 7 days 1 month 1 year Reset Wind Speed Records 1 Press the WIND button to view wind speed records 2 Hold the CLE...

Page 13: ...d Cups Wind Vane and Battery Compartment are securely fastened The Breeze Sensor should be mounted with the Wind Cups on the top Positioning the Breeze Sensor 13 r r Pole Adapter Used in place of the...

Page 14: ...ts and many others Any of these can be combined with U bolts for attachment onto a tall cylindrical conduit using our Adjustable Base Please note that these advanced options will require additional eq...

Page 15: ...Based on current temperature wind speed heat index wind chill Current Outdoor Humidity 8 9 OUTDOOR HUMIDITY Viewing Temperature Humidity Readings 1 2 3 4 5 6 7 8 9 3 WIND ICON Indicates the Temperatur...

Page 16: ...stamps View Temperature Humidity Records Temperature Humidity Records Order Humidity Records 1 Press the TEMP button to view the individual temperature and humidity records you would like to reset 2...

Page 17: ...re Outdoor High Humidity Outdoor Low Humidity Indoor High Temperature Indoor Low Temperature Indoor High Humidity Indoor Low Humidity Wind Rain or Pressure Alert Alert Indicators Active Alert When the...

Page 18: ...ed by the 6 forecast scenes below Watch our Forecast Icons Video for more details bit ly forecast_vid Seasonal Trees Trend Arrows The Trend Arrows represent the change in pressure over the past 3 hour...

Page 19: ...adjust the backlight intensity There are 4 brightness levels plus an off option Adjustable Backlight BACKLIGHT AUTO DIM Auto Dim Settings 1 Hold the LIGHT button to enter the Auto Dim Settings Menu 2...

Page 20: ...eeze Sensor Your station will start to search for a new signal 3 Install new batteries into the add on sensor and press the TX button inside its battery compartment The LED light on the sensor will fl...

Page 21: ...he Add on TH sensor Factory Restart Hold the RAIN and LIGHT buttons together for several seconds to reset the station All records will be lost 21 Ask questions watch setup videos and provide feedback...

Page 22: ...0 C to 50 C Indoor Humidity Range 10 to 99 RH Relative Pressure Range 23 62 to 32 48 InHg 800 to 1100 hPa Power Requirements 5 volt power adapter included AC6 GPU280500150WAOO Input 5 0VAC 150mA Optio...

Page 23: ...cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Caution Any changes or modifications not expressly approve...

Page 24: ......