Generating a new transmission code:

The  radio  control  system  is  provided  with 

preset  codes.  Should  new  codes  be  requi-

red, proceed as follows: Press simultaneously 

buttons:

for  two  seconds.  When  Leds  light  on,  press 

buttons: 

(within 5 seconds). Leds flashing 3 times in-

dicate

the procedure is completed.

WARNING! This  operation deletes  perma-

nently the preset codes.

Learning the new transmission code:

Once the transmission code is changed in the 

radio control unit, the electronic central unit 

of the cooker hood must be made to set the 

new code in the fol- lowing way:

Press the main power-off button of the hood 

and then restore power to the electronic con-

trol unit. Within the next 15 seconds, press 

the Liight Button        to synchronise the cen-

tral unit with the code.

Reset of the Factory configuration:

To  restore  the  Factory  configuration,  follow 

the  pro-  cedure  described  below:  press  si-

multaneously buttons:

for 2 seconds. When Leds light on, press but-

tons:

RC001

R

ADIO

 C

ONTROL

Radio control used for the remote operation 

of ducted cooker hoods.

TECHNICAL DATA

- Alkaline battery powered: 12 V mod. 27A

- Operating frequency: 433.92 Mhz

- Combinations: 32.768

- Max. consumption: 25 mA

- Operating temperature: -20 ÷ + 55 °C

- Dimensions: 130x45x15 mm.

OPERATING DESCRIPTION

The  transmitter  is  equipped  with  5  buttons 

for  cooker  hood  management,  as  specified 

below:

 

: Light ON/OFF command.

 

: Motor ON (speed level 1) / OFF command.

 

: Reduce speed.

 

: Increase speed.

 

: 10-minute timer.

INITIAL OPERATING CONDITION

The manufacturer supplies the radio control 

unit ready to be used with codes preset in the 

Factory 

OPERATION MODE 

Standard configuration:

Standard  configuration  requires  all  “cooker 

hoods  –  radio  control  -  system”  to  be  pro-

vided  with  the  same  transmission  code.  In 

the  event  two  cooker  hoods  –  radio  control 

system are installed in the same room or ne-

arby, each system may affect the operation of 

the another. Therefore, the code of one radio 

control system must be changed.

Summary of Contents for H1LP

Page 1: ...NSTALLATION L EMPLOI ET L ENTRETIEN DE LA HOTTE CornuF EN INSTALLATION USE AND MAINTENANCE OF HOOD CornuF IT ISTRUZIONE PER L INSTALLAZIONE L USO E LA MANUTENZIONE DEL PRODOTTO CornuF DE BEDIENUNGSANL...

Page 2: ...2 REFERENCES IN THE TECHNICAL DATA PLATE For CE MARKET Family FSEB ED Model S84 E Equipment BC84 E A B 7I3 For CSA MARKET Family FSUA Model SU84 Equipment I3 A B 7I3...

Page 3: ...Uses Dimensions and technical sketch of the product Conformity to the European directives on the Recycling Of Electrical And Electronic Equipment Electrical diagram Installation Working Maintenance C...

Page 4: ...ate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels not applicable to appliances that only discharge the air back into the room Air captur...

Page 5: ...gative pressure in the room which can t exceed the limit of 0 04 mbar in order to avoid the suck of exhausts deriving from the heat source Therefore the room should be provided with air intakes to all...

Page 6: ...Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American So ciety for Heating Refrigeration...

Page 7: ...extinguisher and you already know how operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit...

Page 8: ...21 DIMENSIONS AND TECHNICAL SKETCH OF THE HOOD...

Page 9: ...Pa W 250 W 265 4 1 000 m3 h 63 dba 480 Pa W 265 3 X lamp 20W 2 X filter 415mmX350mmX25mm Air outlet 150mm Motor 600cfm Alluminium USA 120V Puissance speed Capacity Noise level Pressure Absorption W 12...

Page 10: ...with directives and standards Range hoods manufactured for USA and Canada are cCSAus certified according to standard requirements CONFORMITY TO THE EUROPEANDIRECTIVES ON THE RE CYCLING OF ELECTRICAL...

Page 11: ...c screws to complete the installation insert the two fixing screws in the rear of the cooker hoods in the 2 holes previously made Before fixing the chimneys connect the power supply behind the decorat...

Page 12: ...th rate level switch F 10 minute timer remote control for the command to distance of cooker hoods TECHNICAL DATA Alkaline battery powered 12V Mod 23A Operating frequency433 92Mhz Combinations 4096 con...

Page 13: ...cribed below press si multaneously buttons for 2 seconds When Leds light on press but tons RC001 RADIO CONTROL Radio control used for the remote operation of ducted cooker hoods TECHNICAL DATA Alkalin...

Page 14: ...cifications set out in the Directive RED 2014 53 EU WARNING Any adjustments or modifications which have not been expressly approved by the holder of the legal conformity certificate may invalidate the...

Page 15: ...buttons Press the timer button to reset The grease filter needs cleaning by regular hand washing or in dishwashers every two months at least or depending on its use To clean the appliance itself tepid...

Page 16: ...owever a hand crafted enamel surface is never completely even and slight variations in shade may occur This is a guarantee of quality and is linked to the nature of our enamelling process This warrant...

Page 17: ...82 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6...

Page 18: ...Fig 7 Fig 8 Fig 9 Fig 10 83...

Page 19: ...nt Z I les B thunes 95310 Saint Ouen l Aum ne FRANCE Adresse postale La Cornue SAS B P 99006 95070 Cergy Pontoise Cedex FRANCE T l 33 0 1 34 48 36 36 Fax 33 0 1 34 64 32 65 E mail a table la cornue co...

Reviews: