INSTALLATION GUIDE FOR
“C
HÂTEAU
” RANGE
- G4
08NOTINSTALG4/EN - 3
68
CONNECTIONS
1.
ELECTRICAL CONNECTIONS
“La Cornue” appliances are delivered with one to three flexible power cables, reference H07 RN-F, made
up of three or five conductors, about 1.5 m long, ready to be connected permanently to the fixed piping on
a 220-240 V AC single-phase of 400 V AC three-phase + n earth power supply, depending on the
indications on the order form (see the relevant table for the model for the powers).
The overall wattage of your appliance is also indicated on the rating plate and on the warranty certificate
(See pt.4, page 15 for the location of the plate).
If the wire is damaged, it must be replaced by the manufacturer, its after sales services or qualified
persons in order to avoid hazard. All of the electricity supply circuits must be disconnected before
accessing the connection terminal boxes.
REMINDER: the appliance should be connected to the main power supply via terminal blocks and not by
means of simple plugs.
Insert the cable below the hot air outlets at the back of the oven, never in front of them.
Should your appliance be connected to a different type of power supply at a later date, in some cases
(please contact our technical department before) it will be possible to change the cabling accordingly,
according to the following instructions:
Open the connection box on the back of the appliance using a flat-head screwdriver. Press the screwdriver
horizontally into the slots on the left and right below the box and push up the latches in the box cover.
Remove the cover.
Connection box
Opening the connection box
Access the connection terminal block(s) to which the various heating elements are connected (if there are
2 or 3 supply cables on the cooker, there will also be 2 or 3 connection terminal blocks).