background image

9

Multi-Protocol Operation 

Analog Operation

This decoder can also be operated on analog layouts or areas of track that are 

analog. The decoder recognizes alternating current (DC) and automatically adapts 

to the analog track voltage. All functions that were set under mfx or DCC for analog 

operation are active (see Digital Operation).

The built-in sound functions come from the factory inactive for analog operation.

Digital Operation

The decoders are multi-protocol decoders. These decoders can be used under the 

following digital protocols: mfx or DCC.

The digital protocol with the most possibilities is the highest order digital protocol. 

The sequence of digital protocols in descending order is:

Priority 1: mfx; Priority 2: DCC; Priority 3: DC

Note:

 Digital protocols can influence each other. For trouble-free operation, we re-

commend deactivating those digital protocols not needed by using CV 50. Deactivate 

unneeded digital protocols at this CV if your controller supports this function. 

If two or more digital protocols are recognized in the track, the decoder automatically 

takes on the highest order digital protocol, example: mfx/DCC; the decoder takes on 

the mfx digital protocol (see previous table).

Note: 

Please note that not all functions are possible in all digital protocols. Several 

settings for functions, which are supposed to be active in analog operation, can be 

done under mfx and DCC.  

Notes on digital operation 

•   The operating instructions for your central unit will give you exact procedures for 

setting the different parameters. 

•   The values set at the factory have been selected for mfx in order to guarantee the 

best possible running characteristics.  

Adjustments may have to be made for other operating systems. 

mfx Protocol

Addresses 

•   No address is required; each decoder is given a one-time, unique identifier (UID).

•   The decoder automatically registers itself on a Central Station or a Mobile Station 

with its UID-identifier.

Programming 

•   The characteristics can be programmed using the graphic screen on the Central 

Station or also partially with the Mobile Station.

•   All of the Configuration Variables (CV) can be read and programmed repeatedly.

•   The programming can be done either on the main track or the programming track.

•   The default settings (factory settings) can be produced repeatedly.

•   Function mapping: Functions can be assigned to any of the function but-

tons with the help of the 60212 Central Station (with limitations) and with the 

60213/60214/60215 Central Station (See help section in the Central Station).

DCC Protocol

Addresses 

•   Short address – long address – multiple unit address

•   Address range:  

1 – 127 for short address and multiple unit address,  

1 – 10.239 for long address 

•   Every address can be programmed manually.

•   Short or long address is selected by means of CV 29 (Bit 5).

•   A multiple unit address that is being used deactivates the standard address. 

Programming

•   The characteristics can be changed repeatedly using the Configuration Variables (CV).

•   The CV numbers and the CV values are entered directly.

•   The CVs can be read and programmed repeatedly. (Programming is done on the 

programming track.)

•   The CVs can be programmed in any order desired. (PoM - Programming can be done 

on the main track). PoM is not possible with CVs CV 1, 17, 18, and 29. PoM must be 

supported by your central controller (Please see the description for this unit.).

•   The default settings (factory settings) can be produced repeatedly.

•   14 or 28/126 speed levels can be set.

•   All of the functions can be controlled according to the function mapping (see CV 

description).

•   See the CV description for the DCC protocol for additional information.

We recommend that in general programming should be done on the programming track.

Summary of Contents for 20981

Page 1: ...Modell der K s St E Dampflok I K 20981...

Page 2: ...2...

Page 3: ...n handhaving 18 Schakelbare functies 18 CV 19 Afbeeldingen 28 Onderdelen 29 Indice del contenuto Pagina Avvertenze per la sicurezza 24 Avvertenze importanti 24 Funzioni 24 Avvertenze per ilfunzionamen...

Page 4: ...gie f r Mobile Station Central Station Name ab Werk I K Nr 3 Die Funktionen k nnen nur parallel aufgerufen werden Die seriealle Funktionsaus l sung ist nicht m glich beachten Sie hierzu die Anleitung...

Page 5: ...ysteme m ssen gegebenenfalls Anpassungen get tigt werden mfx Protokoll Adressierung Keine Adresse erforderlich jeder Decoder erh lt eine einmalige und eindeutige Kennung UID Der Decoder meldet sich an...

Page 6: ...usch Pfeife lang 1 Sound 1 Ger usch Bremsenquietschen aus 2 BS Ger usch Glocke 3 Sound 3 Ger usch Ansage 4 Sound 4 Ger usch Kohle schaufeln 5 Sound 9 Ger usch Betriebsger usch 1 2 6 FS Rauchgenerator...

Page 7: ...4 28 128 Bit 2 Analogbetrieb aus an Bit 5 kurze lange Adresse aktiv 0 1 0 2 0 4 0 32 6 50 Alternative Formate Bit 1 Analog DC Bit 2 MM Bit 3 mfx aus an 0 2 0 4 0 8 15 60 Multibahnhofsansage Bit 0 3 An...

Page 8: ...echnology for the Mobile Station Central Station Name set at the factory I K Nr 3 The functions can be activated only in parallel Serial activation of the functions is not possible Please note here th...

Page 9: ...es No address is required each decoder is given a one time unique identifier UID The decoder automatically registers itself on a Central Station or a Mobile Station with its UID identifier Programming...

Page 10: ...fect Squealing brakes off 2 BS Sound effect Bell 3 Sound 3 Sound effect Announcement 4 Sound 4 Sound effect Coal being shoveled 5 Sound 9 Sound effect Operating sounds 1 2 6 FS Smoke generator 7 AUX 5...

Page 11: ...of speed levels 14 28 128 Bit 2 Analog operation off on Bit 5 short long address active 0 1 0 2 0 4 0 32 6 50 Alternative Formats Bit 1 Analog DC Bit 2 MM Bit 3 mfx off on 0 2 0 4 0 8 15 60 Multi stat...

Page 12: ...ducteurs de courant Commutateur de s lection du mode d exploitation Dans la cabine de conduite du mod le se trouve un interrupteur 4 positions pour la s lection du mode d exploitation fig 1 Pos 0 Loco...

Page 13: ...onfigurations variables CV peuvent tre lues et programm es de fa on r it r e La programmation peut tre r alis e soit sur la voie principale soit sur la voie de programmation Les param trages par d fau...

Page 14: ...rincement de freins d sactiv 2 BS Bruitage Cloche 3 Sound 3 Bruitage Annonce 4 Sound 4 Bruitage Pelletage du charbon 5 Sound 9 Bruitage Bruit d exploitation 1 2 6 FS G n rateur de fum e 7 AUX 5 SUSI F...

Page 15: ...2 Mode analogique d sactiv activ Bit 5 Adresse courte longue activ e 0 1 0 2 0 4 0 32 6 50 Formats alternatifs Bit 1 Analogique c c Bit 2 MM Bit 3 Mfx d sactiv activ 0 2 0 4 0 8 15 60 Annonce en gare...

Page 16: ...het Mobile Station Central Station Naam af de fabriek I K Nr 3 De functies kunnen alleen parallel geschakeld worden Het serieel schakelen van de functies is niet mogelijk zie hiervoor ook de gebruiks...

Page 17: ...ten eventueel aanpassingen uitgevoerd worden mfx protocol Adressering Een adres is niet nodig elke decoder heeft een nmalig en nduidig kenmerk UID De decoder meldt zich vanzelf aan bij het Central Sta...

Page 18: ...1 LV LR Geluid fluit lang 1 Sound 1 Geluid piepende remmen uit 2 BS Geluid luidklok 3 Sound 3 Geluid omroepbericht 4 Sound 4 Geluid kolenscheppen 5 Sound 9 Geluid bedrijfsgeluiden 1 2 6 FS Rookgenerat...

Page 19: ...ogbedrijf uit aan Bit 5 kort lang adres actief 0 1 0 2 0 4 0 32 6 50 Alternatief formaat Bit 1 Analoog DC Bit 2 MM Bit 3 mfx uit aan 0 2 0 4 0 8 15 60 Multi station omroep Bit 0 3 aantal stations Bit...

Page 20: ...n funcionamiento con mfx la locomotora es identificada autom ticamente Tecnolog a mfx para la Mobile Station Central Station Nombre de f brica I K Nr 3 Las funciones se pueden ejecutar solo en paralel...

Page 21: ...garantizada el mejor comportamiento de marcha posible Para otros sistemas operativos tambi n deben realizarse adaptaciones Protocolo mfx Direccionamiento No se requiere direccionamiento recibiendo ca...

Page 22: ...de la rueda Asegurarse de que el aro de adherencia est correctamente asentado Reensamblar el modelo en miniatura Funciones conmutables Faros 1 LV LR Ruido del silbido larga 1 Sound 1 Ruido Desconectar...

Page 23: ...n corta larga activa 0 1 0 2 0 4 0 32 6 50 Formatos alternativos Bit 1 Anal gico DC Bit 2 MM Bit 3 desactivar activar mfx 0 2 0 4 0 8 15 60 Locuci n multiestaci n Bit 0 3 N mero de estaciones Bit 4 L...

Page 24: ...n Nome di fabbrica I K Nr 3 Le funzioni possono venire messe in azione solo in modo parallelo L azionamento seriale delle funzioni non possibile prestate attenzione a questo proposito alle istruzioni...

Page 25: ...rizzo necessario ciascun Decoder riceve una sua identificazione irripetibile e univoca UID Il Decoder si annuncia automaticamente ad una Central Station oppure Mobile Station con il suo UID identifica...

Page 26: ...abili Illuminazione 1 LV LR Rumore Fischio lunga 1 Sound 1 Rumore stridore dei freni escluso 2 BS Rumore Campana 3 Sound 3 Rumore annuncio 4 Sound 4 Rumore Spalatura del carbone 5 Sound 9 Rumore rumor...

Page 27: ...cia 14 28 128 Bit 2 esercizio analogico attivo escluso Bit 5 indirizzo breve lungo attivo 0 1 0 2 0 4 0 32 6 50 Formati alternativi Bit 1 DC analogica Bit 2 MM Bit 3 mfx spento attivo 0 2 0 4 0 8 15 6...

Page 28: ...1 2 3 Bild 1 Betriebsartenschalter Fig 1 Power control switch Img 1 Modes d exploitation Afb 1 Bedrijfssoorten schakelaar Fig 1 Selector de modo de funcionamiento Figure 1 Commutatore del tipo di eser...

Page 29: ...29 6 5 5 1 4 16 9 8 7 7 8 7 4 2 3 Details der Darstellung k nnen von dem Modell abweichen...

Page 30: ...30 8 8 11 18 18 22 15 18 12 14 28 13 17 19 23 24 28 20 7 7 7 21 10 22 25 26 28 27 28 15 17 28 26 18 18 11 Details der Darstellung k nnen von dem Modell abweichen...

Page 31: ...n Teile die hier nicht aufgef hrt sind k nnen nur im Rahmen einer Reparatur im M rklin Reparatur Service repariert werden Note Several parts are offered unpainted or in another color Parts that are no...

Page 32: ...M rklin Cie GmbH Stuttgarter Stra e 55 57 73033 G ppingen Germany www lgb de 353367 1223 Sm1Ef nderungen vorbehalten Gebr M rklin Cie GmbH La locomo ve se recycle www maerklin com en imprint html PAP...

Page 33: ...Erweiterte Decoderwerte Werkseinstellung 20981...

Page 34: ...sive knowledge of working with DCC La liste suivante indique la configuration d usine du d codeur pour r f 20981 en ce qui concerne le mappage de fonctions Les param tres peuvent tre modifi s plusieur...

Page 35: ...Event 353 0 Zuweisung31 Trigger 354 16 Zuweisung31 Flags 355 82 Zuweisung31 Event CV Value Description CV Wert Bedeutung 284 12 Zuweisung8 Trigger 285 0 Zuweisung8 Flags 286 81 Zuweisung8 Event 287 7...

Page 36: ...vent 425 255 Zuweisung55 Trigger 426 0 Zuweisung55 Flags 427 255 Zuweisung55 Event CV Value Description CV Wert Bedeutung 356 5 Zuweisung32 Trigger 357 0 Zuweisung32 Flags 358 83 Zuweisung32 Event 359...

Page 37: ...t 497 255 Zuweisung79 Trigger 498 0 Zuweisung79 Flags 499 255 Zuweisung79 Event CV Value Description CV Wert Bedeutung 428 255 Zuweisung56 Trigger 429 0 Zuweisung56 Flags 430 255 Zuweisung56 Event 431...