![L.B. White Premier CS700 Owner'S Manual And Instructions Download Page 10](http://html1.mh-extra.com/html/l-b-white/premier-cs700/premier-cs700_owners-manual-and-instructions_3216512010.webp)
Premier Ductable Heater
www.lbwhite.com
Owner’s Manual • Premier Ductable Heater
10
The vaporization of propane is affected by several
factors: the surface area of the container, the liquid level
of propane, temperature surrounding the container, and
the relative humidity. All of these factors are specific to a
site. Therefore, a degree of experience and judgement is
required to select the proper propane supply.
Although experience is the best guide, the following
recommendations can be used as a starting point. The
table is based on experience in northern climates where
cold weather and high humidity are prevalent in the
winter. If more or less favorable conditions prevail at a
specific site, adjustments can be made on the basis of
experience.
If more than one gas supply container is used per heater,
the containers must be manifolded together to allow
vapor withdrawal simultaneously from multiple containers.
Manifold system shall be in accordance with NFPA 58 or
CSA B149.1.
Gas Hose and Regulator
(Optional accessories )
Gas Hose:
1 in. x 15 ft. (2.5 cm x 4.6 m): 500-132047
NOTE:
The gas hose and regulator are not shipped with
the heater. They are optional accessory and must
be ordered separately.
Gas Hose
1. The heater has a 1 in. (2.5 cm) NPT pipe nipple at the
gas inlet of the heater. See Fig. 1.
2. With the appropriate connection, attach the hose fitting
and hose to the pipe. Tighten securely.
3. Leak check the connection with an approved leak
detector.
Gas Supply Sizing
Recommended Gas Supply
TANK SIZE
HEATERS / TANK
500 gal. / 1892 litre
1
1000 gal. / 3784 litre
2
FIG. 1
Regulator
WHEN USING PROPANE GAS: 500-25141
1. Lift the tank’s cover.
2. Assemble the gas component as shown, depending on
heater type. Tighten connections securely. See Fig. 2.
FIG. 2
3. Form the pigtail connector, supplied with regulator kit
500-25141, to ensure the regulator will be supported
by the tank, and the tank valve cover will protect the
regulator from weather conditions.
4. Thread connector’s POL fitting courter-clockwise into
the tank valve. See FIG. 2.
5. Open the tank valve slowly.
6. Check all connections with an approved leak detector.
Close the tank’s cover.
1 IN. NPT PIPE
REDUCING
BUSHING
1/4 IN.
NPT
POL
PIGTAIL CONNECTOR
TANK VALVE