background image

Remote Fuel Hook-up Foreman 230/500 Oil

Installation Instructions •Remote Fuel Hook-up Foreman 230/500 Oil 

www.lbwhite.com

Installation Instructions • 

Remote Fuel Hook-up Foreman 230/500 Oil

2

A. Initial Preparation:

1.  Have a sufficiently large enough fuel resistant 

container ready to catch any fuel expelled from the 

pump during removal of the hoses.

2.  Disconnect the heater’s electrical supply.

B.  Pre-assemble the Remote Fuel Hook-Up

•  Attach the hose adapter fittings provided with the kit 

to the remote fuel hook-up. See Figure 1.

FIG. 1

C. Disconnecting Fuel Hoses 

1.  Disconnect the return fuel hose at the elbow and 

from the pump. Save this hose to be used later.

2.  Remove the elbow from the tank and cap off the 

nipple with the 3/8” cap provided with the kit.

If you are attaching an external fuel tank to 

the heater, continue to C3. Otherwise, skip 

to section C8.

3.  Remove the hose connection from the inlet of the 

fuel filter. 

DO NOT

 remove the hose connection 

at the elbow of the fuel tank.

4.  Remove the bushing and the hose adapter from 

the inlet of the fuel filter.

5.  Attach the previously removed hose adapter 

and bushing from step 4 to the hose’s swivel nut 

removed in step 3.

6. Slide the ring of the blue cap onto the hose.

Hose

Adapter Fittings

Swivel Nut

Hose Fitting

DO NOT

REMOVE

Bushing

Hose

Adapter

Reviews: