WIRE SELECTION TABLE

FASTENER SELECTION TABLE

Description

Color

Length

Part Number

Wire, Burner to Gas Control Valve

Green

46 cm

20138

Wire, Motor to Ground

Green/Yellow

36 cm

21194

Wire, Terminal “L1” and “IND” on Ignition Control to Wire Nuts

Brown

33 cm

20569

Wire, High Limit Switch to Gas Control Valve

Yellow

56 cm

20570

Wire, Terminal “L2” on Ignition Control to Wire Nut

Blue

29 cm

20571

Wire, Terminal “W” on Ignition Control to Transformer

Yellow

14 cm

20660

Wire, Terminal “C” on Ignition Control to Transformer

Green

16.5 cm

20661

Wire, Toggle Switch and Transformer to Wire Nut

Brown

19 cm

20662

Wire, Toggle Switch to Wire Nut

Blue

15 cm

20663

Wire, Toggle Switch to Transformer

Blue

14 cm

20664

Wire, Burner to Ground

Green/Yellow

168 cm

21192

Wire, Gas Control to Ground

Green/Yellow

168 cm

21193

Description

Application

Part Number

Bolt, 3/8

Burner Mounting

02692

Nut, Cage

Case Top (for hanging)

07708

Nut, Hex

Toggle Switch Nut

20683

Nut, Hex, Locking

Transformer Mounting

83172

Screw

Igniter Bracket to Burner

01213

Screw

Transformer Mounting

05552

Screw

Ignition Control

02330

Screw

Burner

02688

Screw

Flame Sensor Mounting

03027

Screw

High Limit Switch

06658

Screw

Igniter Mounting

07240

Screw

Used in all other applications

07288

Washer, Flat

Burner Mounting

01589

Washer, Lock

Igniter Mounting

02726

Summary of Contents for AW230

Page 1: ...ating heater for the heating of agricultural animal confinement buildings The heater is approved for either indoor or outdoor mounting If you are considering using this product for any application oth...

Page 2: ...ury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater can result in Death Serious bodily injury or burns Property damage or loss...

Page 3: ...cal L B White distributor or the L B White Co Inc for assistance or if you have any questions about the use of the equipment or its application The L B White Co Inc has a policy of continuous product...

Page 4: ...as Gas Model Ventilation Air Required to Support Combustion 1 83 Meters Reference AS1596 and AS5601 Gas Installations Burner Manifold Pressure Electrical Supply Volts Hz Phase Amp Draw Starting Amps I...

Page 5: ...ss and difficulty in breathing Symptoms of improper combustion affecting livestock can be disease lower feed conversion or death Asphyxiation Hazard Some people cannot smell well Some people cannot sm...

Page 6: ...e fuel gas containers or fuel supply hoses anywhere near the blower outlet of the heater 8 Do not block air intakes or discharge outlets of the appliance Doing so may cause improper combustion or dama...

Page 7: ...f pipe compound before further tightening Further tighten the gas connections as necessary to stop the leak After all connections are checked and any leaks are stopped turn on the main burner Stand cl...

Page 8: ...ts found in performing any of the service or maintenance procedures must be eliminated and defective parts replaced immediately The heater must be retested by properly qualified service personnel befo...

Page 9: ...mounted in a vertical position Make sure pipe thread compound that is resistant to both L P and natural gas is used in making all connections Check all connections for gas leaks using approved gas lea...

Page 10: ...ring of a thermostat must be done by an electrician or someone properly qualified b The thermostat may use 18 gauge 2 wire cord to handle the low voltage being supplied to the thermostat from the tran...

Page 11: ...tance in troubleshooting Only qualified and properly trained personnel shall service or repair the heater 7 On a call for heat the motor will start up and run for five 5 seconds and then stop This pre...

Page 12: ...d the area between the heat chamber top and inside case is also free of dust Additionally the flame sensor should be removed and cleaned according to the service instructions within this Owner s Manua...

Page 13: ...ITCH ARM FANWHEEL PIVOT POINT OF FLAPPER EDGE OF FLAPPER PIVOT POINT OF FLAPPER FLAPPER 31 7 MMTO 34 9 MM 1 Shut off the gas supply to the heater 2 Disconnect the heater from its electrical supply 3 M...

Page 14: ...nlet pressures to gas control valve are shown in the heater specifications table See page 4 and on the heater s dataplate The inlet pressure may need adjustment as necessary to achieve proper manifold...

Page 15: ...sensor IMPORTANT For proper flame sense operation the flame sensor tip must be properly positioned within the burner flame Normally 12 7 mm to 19 mm is sufficient See Fig 13 FIG 13 The high limit swi...

Page 16: ...it will relate directly to problem solving provided by the flow charts The ignition control module is self diagnostic The red light on the module will flash a specific pattern depending upon the probl...

Page 17: ...Switch Closes Gas Control Valve Opens Ignition Occurs Igniter stays Powered up for 6 seconds after Ignition Flame Proving occurs in 6 seconds Igniter Shuts Off Gas Valve Stays Open Room Warms to Desir...

Page 18: ...ly Requirements Provide Proper Voltage From Electrical Supply Check Circuit Breakers in Building Electrical System Check Power Cord for Continuity Replace Thermostat Replace Selector Switch Are 24 Vol...

Page 19: ...Rapid Flash Reverse Polarity Have Electrician Check Neutral and Hot Wire Connections that Outlet Heater is Connected to Long Flash Two Seconds On Two Seconds Off Repetitively for 15 Minutes Heater ha...

Page 20: ...or Check for Housing Alignment Tighten Set Screw s on Fan Make sure Set Screw s are Tightened Against Flat s of Motor Shaft Yes Clean the Fan Wheel with Compressed Air or Soft Brush Defective Motor or...

Page 21: ...is read adjust outlet pressure as necessary B If gas pressure is not read replace the control valve Defective Igniter Perform Continuity Check and Replace Igniter If Necessary Clean Flame Sensor with...

Page 22: ...wire only to determine if part is defective Replace the part IMMEDIATELY or do not operate unit until properly serviced NEVER operate a heater with a jumper wire used to bypass a safety device as a te...

Page 23: ...ons Verify Proper Voltage with a Voltage Tester Contact a Qualified electrician if Proper voltage is not Present No No Yes Is Proper Voltage Supplied to Selector Switch from Power Cord No Problem Moto...

Page 24: ...SOLENOID S TRANSFORMER 240V 24V L E D INDICATOR GROUND POWER CORD IND L1 HSI HSIG L2 W PSI FSI GV PSO FSG C HSI CONTROL SELECTOR SWITCH HEAT OFF VENT TRANSFORMER FOR OPTIONALTHERMOSTAT CONTROL INSTAL...

Page 25: ...oard which sends and receives voltages to various controls in an automatic hot surface ignition system An important safety feature of the control board is that it will shu down the entire heater there...

Page 26: ...Parts Identification PARTS SCHEMATIC 26...

Page 27: ...2 Chamber Heat 20024 23 Door Right 20757 24 Latch Assembly for case assembly and control box 20959 25 Case Assembly with Doors and Latches 21286 26 Hinge 05868 27 Door Left 20756 28 Harness 9 wire 9 m...

Page 28: ...ERCORD EXIT HOLE 21008WARNING WASHDOWN INSTRUCTIONS 20575 WIRING DIAGRAM 21012WARNING FIRE AND EXPLOSION HAZARD INSIDE OF MOTOR END ACCESS DOOR 21280 BADGE AUSTRALIAN LISTED 20453WARNING HOT SURFACES...

Page 29: ...and Transformer to Wire Nut Brown 19 cm 20662 Wire Toggle Switch to Wire Nut Blue 15 cm 20663 Wire Toggle Switch to Transformer Blue 14 cm 20664 Wire Burner to Ground Green Yellow 168 cm 21192 Wire Ga...

Page 30: ...ate of purchase by the end user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months later than the dat...

Reviews: