background image

Guardian Brood Heaters

www.lbwhite.com

Owner’s Manual • Guardian

22

Transformer

Located in the control box, the transformer reduces 220 
VAC to 24 VAC for operation of the the ignition control. 
Without 24 VAC from the transformer, the red diagnostic 
light will not be on and the ignition control will not  
function.

FIG. 20

Gas Pressure Checks

 

Ŷ

The following explains a typical procedure to be  
followed in checking gas pressures.

Ŷ

The gas pressures will vary depending upon fuel type.

Consult the dataplate on the brood heater or page 4 in 

WKLVPDQXDOIRUVSHFL¿FSUHVVXUHVWREHXVHGLQFRQMXQF

-

tion with this procedure.

Gas pressure measured at the inlet to the gas valve is 
Inlet Pressure and gas pressure measured at the outlet of 
the gas valve is Burner Manifold Pressure.

A. Preparation

1.  Obtain two pressure gauges capable of reading up to 

9 kPa in. W.C.

2.  Disconnect the heater from the electrical supply and 

close the fuel supply valve to the brood heater inlet.

WARNING

Ŷ'RQRWGLVDVVHPEOHWKHJDVFRQWUROYDOYH

Ŷ'RQRWDWWHPSWWRUHSODFHDQ\FRPSRQHQWVRIWKH

gas control valve.

Ŷ7KHJDVFRQWUROYDOYHPXVWEHUHSODFHGLIDQ\

physical damage occurs to the control valve 

assembly.

Ŷ)DLOXUHWRIROORZWKLVZDUQLQJZLOOUHVXOWLQ¿UH

or explosions, leading to injury or death, and 

property damage.

3. Open the burner access panel.

4.  Brush or blow off any dust and dirt on or in the vicin-

ity of the gas control valve.

B. Gauge Installation

1.  Locate the inlet and outlet pressure taps, see Fig. 

21. Remove the pressure tap plug using a 3/16 in. 
allen key.

FIG. 21

OUTLET

 

PRESSURE

 

TAP

INLET

 

PRESSURE

 

TAP

ON

OFF

FIG. 22

LOW

 

PRESSURE

 

GUAGE

OUTLET

 

PRESSURE

 

TAP

INLET

 

PRESSURE

 

TAP

LOW

 

PRESSURE

 

GUAGE

E

X

AMPLE

 

SHOWS

 

PRESSURE

 

FOR

 

PROPANE

 

GAS

ALWAYS

 

REFER

 

TO

 

PRESSURE

 

ON

 

DATAPLATE

OFF

ON

INTERNAL

 

PRESSURE

 

REGULATOR

2.  Securely connect a pressure gauge to each  

pressure tap.

3.  Open the fuel supply valves to the heater and  

reconnect the heater electrical supply.

4. Start the heater

C. Reading Pressures

1.  With the brood heater operating, the pressure 

JDXJHVVKRXOGUHDGWKHSUHVVXUHVVSHFL¿HGRQWKH

dataplate.

2.  Do the readings at the inlet and outlet pressure 

JDXJHVDJUHHZLWKWKDWVSHFL¿HGRQWKHGDWDSODWH"

If so, then no further checking or adjustment is 
required. Proceed to section D.

,IWKHLQOHWSUHVVXUHVGRQRWDJUHHZLWKWKDWVSHFL¿HG

on the dataplate, then the regulator controlling gas 
pressure to the brood heater requires adjustment.

 

Summary of Contents for AD060

Page 1: ...ildings and is approved for indoor or outdoor mounting If you are considering using this product for any application other than it s intended use contact your local agent or the L B White Company LLC...

Page 2: ...O 9DOYH DQG XUQHU 2UL FH 21 Ignition Control 21 Transformer 22 Gas Pressure Checks 22 Troubleshooting Guide 24 Electrical Connection and Ladder Diagram 29 Brood Heater Component Function 30 3DUWV GHQW...

Page 3: ...7 THIS BROOD HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY OR BURNS PROPERTY DAMAGE OR LOSS FROM FIRE OR EXPLOSION 63 7 21 8 72 2 48 7 5 6833 25 5 21 0212 POISONING 75 6 2 5 7 6 2 1 5 6 0 18 25 16...

Page 4: ...N A Motor Characteristics Watts RPM Ball Bearing 50 1450 150 1300 186 1150 373 950 Electrical Supply Volts Hz Phase 220 240 50 1 220 240 50 1 230 60 1 220 240 50 1 Amp Draw Starting 1 2 2 0 3 5 220 2...

Page 5: ...nderstand the brood heater and how it functions The gas supply line installation installation of the brood heater and repair and servicing of the brood heater requires continuing expert training and k...

Page 6: ...o give you a scratch and sniff pamphlet Use it to become familiar with the fuel gas odor 6PRNLQJ FDQ GHFUHDVH RXU DELOLW WR VPHOO HLQJ around an odor for a period of time can affect your sensitivity t...

Page 7: ...ate and national codes as well as the manufacturer s requirements 2 All installations and applications of L B White brood heaters must meet all relevant local state and national codes Included are LPG...

Page 8: ...ult in electrical shock personal injury or death 14 Direct ignition brood heaters will make up to three trials for ignition If ignition is not achieved the control system will lock out the gas control...

Page 9: ...g installation and perform gas leak test after completion of installation R QRW IRUFH WKH JDV FRQWURO NQRE 8VH RQO RXU hand to turn the gas control knob Never use any tools If the knob will not operat...

Page 10: ...lation of the brood heater 14 Light accordance to instructions on the brood heater or within owner s manual 15 It is extremely important to use the proper size and type of gas supply line to assure pr...

Page 11: ...ng to the illustration and tighten all eyebolts securely See Fig 2 FIG 2 EYEBOLT NUT FLATWASHER CAGE NUT CHAIN CASETOP 2 Be sure the brood heater is securely fastened and is hanging level Check crossw...

Page 12: ...ack lead of the thermostat kit to the 24 volt output terminal of the transformer e Connect the white lead of the thermostat kit to terminal W of the ignition control f Install the strain relief suppli...

Page 13: ...at the fan motor end of the brood heater for assistance LQ WURXEOHVKRRWLQJ 2QO TXDOL HG DQG SURSHUO trained personnel shall service or repair the brood heater 5 On a call for heat the motor will start...

Page 14: ...he individual fan blades Additionally make sure the burner air inlet venturi ports and the throat of the casting are free of dust accumulation and the area between the heat chamber top and inside case...

Page 15: ...for legibility Ensure that none are cut torn or otherwise damaged Any damaged markings must be replaced immediately by contacting L B White Co Inc Markings are available at no cost 5HSODFH WKH FRPSOHW...

Page 16: ...maintenance or cleaning DLOXUH WR IROORZ WKLV ZDUQLQJ ZLOO UHVXOW LQ EXUQV causing injury WARNING Fire and Explosion Hazard R QRW GLVDVVHPEOH RU DWWHPSW WR UHSDLU DQ brood heater components or gas tra...

Page 17: ...th bracket to blower housing Remove the assembly by turning the switch so the paddle on the switch arm can be pulled through the oblong hole on side of fan housing AW325 service Fig 9b Remove the two...

Page 18: ...uildup If the spark appears strong but the brood heater cycles off rub the sensor rod with emery cloth or steel wool to remove any build up Ensure the igniter gap to burner is 4 mm and the igniter tip...

Page 19: ...odel AD060 AD100 AD250 The high limit switch is located on the heat chamber See Fig 13a and 13b ModelAD325 The high limit switch is located on the fan housing side panel at the motor end of the heater...

Page 20: ...EXWWRQ RQ WKH VZLWFK 4 Check for electrical continuity across the switch terminals to make sure the contacts have closed 5 Reinstall the switch back into the brood heater Re connect the brood heater...

Page 21: ...nds and receives voltages to operate or verify operation of components Refer to the following and Fig 19 to understand the ignition control s terminal designators if doing voltage checks on the contro...

Page 22: ...H UHSODFHG LI DQ physical damage occurs to the control valve assembly DLOXUH WR IROORZ WKLV ZDUQLQJ ZLOO UHVXOW LQ UH or explosions leading to injury or death and property damage 3 Open the burner acc...

Page 23: ...stment See Fig 22 for regulator location D Completion 1 Once the proper inlet and burner manifold pressures KDYH EHHQ FRQ UPHG DQG RU SURSHUO VHW FORVH WKH fuel supply valve to the brood heater and al...

Page 24: ...n until the problem is corrected Problems Page L E D Diagnostic light not on during a call for heat 26 GLDJQRVWLF OLJKW DVKLQJ A Long Flash 2 seconds ON 2 seconds OFF 26 B One Time 26 C Two Times 27 D...

Page 25: ...Z LPPHGLDWHO LI UVW trial fails Ignition control starts a 15 minute Wait period to allow ignition interruption to pass Ignition control repeats 3 Ignition attempts after 15 minute wait period I LJQLWL...

Page 26: ...cal supply requirements provide proper voltage contact electrician Defective transformer Replace transformer Check wiring between transformer and thermo stat Check continuity Repair as needed Set ther...

Page 27: ...DQ ZKHHO ELQGLQJ Is fan wheel loose on PRWRU VKDIW Is fan wheel plugged ZLWK GLUW Is there an obstruc tion in blower outlet preventing air proving VZWLFK FORVXUH Defective air proving switch Replace s...

Page 28: ...t outlet pressure as necessary B If gas pressure is not read replace the gas control valve 5HPRYH RUL FH DQG EXUQHU casting Blow out with compressed air or clean with a soft brush RHV LJQLWHU VSDUN Is...

Page 29: ...APS HL GV FS L1 IG NEUTRAL IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE BROOD HEATER MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 302 F 150 C...

Page 30: ...f overheat situation Ignition Control Module Controls the ignition sequence and operation of the brood heater as well as monitoring the safety se vices A major service feature is the board s ability W...

Page 31: ...Guardian Brood Heaters Owner s Manual Guardian 31...

Page 32: ...Guardian Brood Heaters www lbwhite com Owner s Manual Guardian 32 Service Parts Identification Schematic AD060 AD100...

Page 33: ...ensor assembly AD060 573165 7b AD100 570021 8 High limit switch AD060 503933 AD100 573099 9 Case assembly with doors and latches galvanized steel stainless steel AD060 573430 573584 Case assembly with...

Page 34: ...Guardian Brood Heaters www lbwhite com Owner s Manual Guardian 34 Parts List AD250...

Page 35: ...Gas 570054 6 Burner mounting hardware 570211 7 Igniter and sensor assembly 570021 8 High limit switch 505566 9 Case assembly with doors and latches galvanized steel stainless steel 572421 573586 10 D...

Page 36: ...Guardian Brood Heaters www lbwhite com Owner s Manual Guardian 36 Accessory Must be ordered separately Parts List AD325...

Page 37: ...doors and latches stainless steel 573633 9 Door burner end stainless steel 573634 10 Door motor end stainless steel 573635 11 Latch kit 570228 12 Wire kit with harness all brood heater wiring 570103...

Page 38: ...Guardian Brood Heaters www lbwhite com Owner s Manual Guardian 38 Notes...

Page 39: ...Guardian Brood Heaters Owner s Manual Guardian 39 Notes...

Page 40: ...r warranties including any implied warranties or merchantability RU WQHVV IRU D SDUWLFXODU SXUSRVH DUH H SUHVVO disclaimed In the event any implied warranty is not hereby effectively disclaimed due to...

Page 41: ...3GYUT 9ZXKKZ 5TGRGYQG RH NOZK IUS GXJOGT RH NOZK IUS 2 NOZK RH NOZK IUS 2 NOZK 2 NOZK 78 NZZV O _U Q IUS RH NOZK 2 NOZK...

Page 42: ...GXJOGT RH NOZK IUS GXJOGT...

Page 43: ...GXJOGT GXJOGT 2 NOZK...

Page 44: ...GXJOGT RH NOZK IUS GXJOGT 4...

Page 45: ...GXJOGT GXJOGT 2 NOZK 2 NOZK 2 NOZK...

Page 46: ...GXJOGT RH NOZK IUS GXJOGT 2 NOZK...

Page 47: ...GXJOGT GXJOGT G H 2 NOZK...

Page 48: ...GXJOGT RH NOZK IUS GXJOGT 9...

Page 49: ...GXJOGT GXJOGT 2 NOZK 2 NOZK...

Page 50: ...GXJOGT RH NOZK IUS GXJOGT 2 NOZK...

Page 51: ...GXJOGT GXJOGT...

Page 52: ...GXJOGT RH NOZK IUS GXJOGT G H I J K L M N...

Page 53: ...GXJOGT GXJOGT ON OFF 2 2 2 2 2...

Page 54: ...GXJOGT RH NOZK IUS GXJOGT G H I...

Page 55: ...GXJOGT GXJOGT 2 NOZK...

Page 56: ...GXJOGT RH NOZK IUS GXJOGT G...

Page 57: ...GXJOGT GXJOGT G H G H G H...

Page 58: ...GXJOGT RH NOZK IUS GXJOGT Q...

Page 59: ...GXJOGT GXJOGT G H G H G FIG 13b G H...

Page 60: ...GXJOGT RH NOZK IUS GXJOGT...

Page 61: ...GXJOGT GXJOGT 2 4 2 3 69 69 9 8 53...

Page 62: ...GXJOGT RH NOZK IUS GXJOGT 54 5 5 54...

Page 63: ...GXJOGT GXJOGT...

Page 64: ...GXJOGT RH NOZK IUS GXJOGT 2 2 2 2 69 4 69...

Page 65: ...GXJOGT GXJOGT...

Page 66: ...GXJOGT RH NOZK IUS GXJOGT 2...

Page 67: ...GXJOGT GXJOGT 4 69 695...

Page 68: ...GXJOGT RH NOZK IUS GXJOGT 9 9...

Page 69: ...F THE ORIGINAL WIRE AS SUPPLIED WITH THE BROOD HEATER MUST BE REPLACED IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 302 F 150 C 150 GV 150 30461 REV A ELECTRICAL CO...

Page 70: ...GXJOGT RH NOZK IUS GXJOGT...

Page 71: ...GXJOGT GXJOGT...

Page 72: ...GXJOGT RH NOZK IUS GXJOGT...

Page 73: ...GXJOGT GXJOGT 46 469 G H 2...

Page 74: ...GXJOGT RH NOZK IUS GXJOGT...

Page 75: ...GXJOGT GXJOGT 16G 16G 46 469 2...

Page 76: ...GXJOGT RH NOZK IUS GXJOGT...

Page 77: ...GXJOGT GXJOGT 16G 16G 46 469 2...

Page 78: ...GXJOGT RH NOZK IUS GXJOGT...

Page 79: ...GXJOGT GXJOGT...

Page 80: ...ZK 2 NOZK 5 2 NOZK 2 NOZK 2 NOZK 2 NOZK 2 NOZK 2 NOZK 2 NOZK 2 NOZK NZZV RH NOZK IUS I YZUSKXE IGXKEIKTZKX VXUJ IZ XKMOYZXGZOUT 2 NOZK 2 NOZK I YZUSKXYKX OIK RH NOZK IUS 3GYUT 9ZXKKZ 5TGRGYQG RH NOZK...

Reviews: