SEDIMENT TRAP ASSEMBLY
NIPPLE
HOSE ADAPTER
TEE
NIPPLE
CAP
TO GAS CONTROL
VALVE INLET
Assemble the tee, nipples and cap together and tighten
securely. See Fig. 6. The sediment trap assembly must
always be mounted in a vertical position. Make sure pipe
thread compound that is resistant to both propane gas and
natural gas is used in making all connections. Check aall
connections ffor ggas lleaks uusing aapproved ggas lleak
detectors.
FIG. 6
REGULATOR
NIPPLE
VALVE, MANUAL
SHUT-OFF
GAS HOSE
ADAPTER
SEDIMENT TRAP
TO CONTROL
VALVE INLET
REGULATOR VENT
GAS FLO
W
13
MANUAL SHUT-OFF VALVE, HOSE
AND REGULATOR ASSEMBLY
1. Always use approved pipe thread compound suitable
for use with propane gas or natural gas on the
threaded connections.
2. Assemble the components together according to the
figure. This view is to show general assembly of the
components only. The regulator must always be
mounted so its vent, regardless of location on the
regulator, is always pointed downward.
3. Tighten all connections securely.
4. Check aall cconnections ffor ggas lleaks uusing aapproved
gas lleak ddetectors.
FIG. 7