40
Mounting and attaching instructions are listed below:
1. Thread the long rod into the base plate.
2. Set both bottles into place as shown.
3. Drop the double hook bracket over the rod and hook onto the
bottle.
4. Attach the wing-nut to hold the bracket and tighten to hold the
bottle to the plate.
5. Attach the regulator with the vent down to the bracket.
6. Attach the main hose from the regulator to the manifold fitting in
the frame.
7. Attach two short pigtail hoses to the regulator and bottles at the
ACME fitting.
8. Test all propane connections for leakage.
To remove the propane containers for refilling:
1. Remove the bottle covers (if used).
2. Close the main valve on the container.
3. Remove the two hoses at the ACME connection.
4. Install the rubber cap over the valve – ACME connection.
5. Remove /loosen the wing nut holding the clamp hook.
6. Remove the clamp hook.
7. Fill the bottle and reverse the procedure to install. Test all con-
nections for leakage.
Regulator
Propane regulators must always be installed with the regulator vent
facing downward. Regulators that are not in compartments have
been equipped with a protective cover. Make sure that the regulator
vent faces downward and that the cover is kept in place to minimize
vent blockage that could result in excessive gas pressure causing
fire or explosion.
PDF created with pdfFactory trial version