![Kyoritsu Electrical Instruments Works KEW3431 Instruction Manual Download Page 16](http://html.mh-extra.com/html/kyoritsu-electrical-instruments-works/kew3431/kew3431_instruction-manual_2017203016.webp)
̶ 14 ̶
Fig. 7-2
7. Voltage measurement
#
DANGER
● Do not apply a voltage exceeding the maximum allowable input
(600V) to the instrument.
● Keep your fingers behind the barrier during a measurement.
● Verify proper operation on a known source before taking actions
as a result of the indication of the instrument
7-1 Measurement method
Set the function switch to V
AC/DC
position to measure voltage.
(1) Connect the test leads as the following figure shows.
・MODEL7260 to Line terminal
・MODEL7261A to Earth terminal
(2) Connect the black test lead to the earth side of the circuit under
test and the red remote probe to the line side.
Fig. 7-1
Red
Black