![Kyocera ECOSYS FS-C5350DN Service Manual Download Page 46](http://html1.mh-extra.com/html/kyocera/ecosys-fs-c5350dn/ecosys-fs-c5350dn_service-manual_2015353046.webp)
2K8
1-3-18
Service items
Description
No.
Items
Description
���
Maintenance
Log
NOTE:
It is not logged if
100 or more
counts are not
added to the
count at the last
occurrence of
replacement.
#
Count.
Item
Remembers 1 to 8 of
occurrence of replace-
ment. If the occurrence of
the previous replacement
of toner container is less
than 8, all of the occur-
rences of replacement
are logged.
The total page count at the
time of the replacement of
the toner container.
This is virtually logged as
the occurrence of the
“Toner Empty” or “Install
MK” condition since the
replacement of the toner
container is not precisely
detectable.
Code of maintenance replacing
item (1 byte, 2 categories)
First byte (Replacing item)
01: Toner container
Second byte (Type of replacing
item)
00: Black
01: Cyan
02: Magenta
03: Yellow
First byte (Replacing item)
02: Maintenance kit
Second byte (Type of replacing
item)
01: Fixed (MK-580)
������
Unknown Toner
Log
NOTE:
It is not logged if
100 or more
counts are not
added to the
count at the last
error.
#
Count.
Item
Remembers 1 to 5 of
occurrence of unknown
toner detection.
If the occurrence of the
previous unknown toner
detection is less than 5,
all of the unknown toner
detection are logged.
The total page count at the
time of the “Toner Empty”
error with using an
unknown toner container.
Unknown toner log code (1
byte, 2 categories)
First byte
01: Fixed (Toner container)
Second byte
00: Black
00: Cyan
00: Magenta
00: Yellow
������
Counter Log
Comprised of
three log
counters includ-
ing paper jams,
self diagnostics
errors, and
replacement of
the toner con-
tainer.
NOTE:
It is not logged if
100 or more
counts are not
added to the
count at the last
error.
(f) Jam
(g) Self diagnostic error
(h) Maintenance item replacing
Indicates the log counter
of paper jams depending
on location.
Refer to Paper Jam Log.
All instances including
those are not occurred
are displayed.
Indicates the log counter of
self diagnostics errors
depending on cause.
(See page 1-4-3)
Example
C6000: 4
Self diagnostics error
6000 has happened four
times.
Indicates the log counter
depending on the maintenance
item for maintenance.
T: Toner container
00: Black
00: Cyan
00: Magenta
00: Yellow
M: Maintenance kit
00: (Fixed)
Example
T00: 1
The (black) toner container has
been replaced once.
This is virtually logged as the
occurrence of the” Toner Empty”
or “Install MK” condition.
Summary of Contents for ECOSYS FS-C5350DN
Page 1: ...SERVICE MANUAL Published in December 2009 2K8SM061 Rev 1 FS C5350DN...
Page 3: ...Revision history Revision Date Replaced pages Remarks 1 December 11 2009 1 4 19 1 4 20 1 5 2...
Page 4: ...This page is intentionally left blank...
Page 10: ...This page is intentionally left blank...
Page 14: ...2K8 This page is intentionally left blank...
Page 20: ...2K8 1 1 6 This page is intentionally left blank...
Page 28: ...2K8 1 2 8 This page is intentionally left blank...
Page 78: ...2K8 1 4 32 This page is intentionally left blank...
Page 126: ...2K8 1 6 8 This page is intentionally left blank...
Page 172: ...2K8 2 3 16 This page is intentionally left blank...
Page 177: ......
Page 178: ......