2LW/2LX-6
1-3-31
U403
Adjust Scanning Margin(Table)
Description
Adjusts margins for scanning the original on the contact glass.
Purpose
Make the adjustment if margins are incorrect.
Adjustment
1. Press the start key.
2. Press the system menu key.
3. Place an original and press the start key to make a test copy.
4. Press the system menu key.
5. Select the item to be adjusted.
6. Change the setting value using the cursor left/right keys or numeric keys.
Increasing the value makes the margin wider, and decreasing it makes the margin narrower.
Figure 1-3-13
7. Press the start key. The value is set.
Caution
If the above adjustment does not optimize the margins, perform the following maintenance
modes.
Completion
Press the stop key. The indication for selecting a maintenance item No. appears.
Item No.
Description
Display
Description
Setting
range
Initial
setting
Change in
value per step
A Margin
Scanner left margin
0.0 to 10.0
2.0
0.5 mm
B Margin
Scanner leading edge margin
0.0 to 10.0
2.0
0.5 mm
C Margin
Scanner right margin
0.0 to 10.0
2.0
0.5 mm
D Margin
Scanner trailing edge margin
0.0 to 10.0
2.0
0.5 mm
Leading edge margin of the copy image
(4.0 +1.5/-1.0 mm)
Left margin of
the copy image
(2.5 +1.5/-2.0 mm)
Right margin of
the copy image
(2.5 +1.5/-2.0 mm)
Trailing edge margin of the copy image
(4.0 mm or less)
U034
(P.1-3-13)
U402
(P.1-3-30)
U403
Summary of Contents for ECOSYS FS-3140MFP
Page 1: ...SERVICE MANUAL Published in May 2013 842LX117 2LXSM067 Rev 7 FS 3040MFP FS 3140MFP ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 104: ...2LW 2LX 1 3 76 This page is intentionally left blank ...
Page 219: ...2LW 2LX 2 1 24 This page is intentionally left blank ...
Page 227: ...2LW 2LX 2 2 8 This page is intentionally left blank ...
Page 251: ...2LW 2LX 2 3 24 This page is intentionally left blank ...
Page 271: ...2LW 2LX 2 4 20 This page is intentionally left blank ...