2L0
1-5-31
(3) Detaching and refitting the eraser lamp (PWB)
Procedure
1. Remove the laser scanner unit (See page 1-
5-29).
2. Remove the connector.
3. Slide the eraser holder.
4. Unhook the hooks and then remove the
eraser holder.
Figure 1-5-43
5. Remove the eraser lamp (PWB) from the
eraser holder.
6. Check or replace the eraser lamp (PWB)
and refit all the removed parts.
Figure 1-5-44
Eraser holder
Eraser holder
Hooks
Hooks
Hooks
Hook
Connector
Eraser holder
Eraser lamp (PWB)