2L0
1-5-21
7. Remove five screws and then remove the
control PWB.
8. Check or replace the control PWB and refit
all the removed parts.
To replace the control PWB, remove the
EEPROM (U300) from the old control PWB
and mount it to the new control PWB.
Figure 1-5-29
Screw
Screw
Screw
Screw
Screw
Control PWB
Control PWB
U300
EEPROM
Summary of Contents for ECOSYS FS-1370DN
Page 1: ...SERVICE MANUAL Published in April 2010 842L0111 2L0SM061 Rev 1 FS 1370DN ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 18: ...2L0 1 1 6 This page is intentionally left blank ...
Page 21: ...2L0 1 2 3 1 Removing the tapes Procedure 1 Remove three tapes Figure 1 2 3 Tape Tape Tape ...
Page 24: ...2L0 1 2 6 This page is intentionally left blank ...
Page 57: ...2L0 1 5 5 5 Unhook seven hooks and then remove the left cover Figure 1 5 6 Left cover Hooks ...
Page 106: ...2L0 2 1 16 This page is intentionally left blank ...
Page 118: ...2L0 2 3 8 This page is intentionally left blank ...
Page 122: ...2L0 2 4 4 This page is intentionally left blank ...
Page 123: ......
Page 124: ......