![Kyocera Mita KM-1505 Service Manual Download Page 83](http://html1.mh-extra.com/html/kyocera-mita/km-1505/km-1505_service-manual_2017036083.webp)
2BT
1-5-13
Causes
Check procedures/corrective measures
1. Dirty or flawed main charger wire.
2. Foreign matter in the developing section.
3. Flawed drum.
4. Dirty shading plate.
(5) A white line appears
longitudinally.
Causes
1. Dirty or flawed main charger wire.
2. Foreign matter in the developing section.
3. Flawed drum.
4. Dirty shading plate.
(3) Image is too
light.
(4) Background is visible.
Causes
1. Insufficient toner.
2. Deteriorated developer.
3. Dirty or deteriorated drum.
Causes
Check procedures/corrective measures
1. Insufficient toner.
2. Deteriorated developer.
3. Dirty or deteriorated drum.
Causes
1. Deteriorated developer.
Causes
Check procedures/corrective measures
1. Deteriorated developer.
Check the number of copies made with the current developer. If it
has reached the specified limit, replace the developer.
If the add toner indicator lights, replace the container.
Check the number of copies made with the current developer. If it
has reached the specified limit, replace the developer.
Clean the drum or, if the maintenance level has been reached,
replace the drum (see page 1-6-29).
Clean the main charger wire or, if it is flawed, replace the main
charger unit.
Check if the magnetic brush is formed uniformly. If not, replace the
developer.
Replace the drum (see page 1-6-29).
Clean the shading plate.