12
. COOLING SYSTEM
12-10
Downtown 125 i
FAN MOTOR SWITCH
REMOVAL
Disconnect the fan motor switch connectors
Remove the thermostat(1).
INSPECTION
Place the thermal switch in the stove with
water as shown and raise the water
temperature gradually to check for the
temperature at which the starts to operate.
If the thermal switch operating temperature
is not within the specified range, replace the
thermal switch with a new one.
OFF
→
ON Over 88
−
92
°
C
ON
→
OFF Lower 88
−
92
°
C
INSTALLATION
Change a new O-ring.
Tighten the cooling fan motor switch to
specified torque.
Torque:
1.8 kgf-m (18 N-m, 13 lbf-ft)
●
Handle the cooling fan motor switch
carefully as it is vulnerable to impact.
*
(1)
●
Replace the O-ring a new one.
●
Do not use grease to the O-ring.
*
Cortesia de/ Courtesy of: www.batmotos.com