18
. EVAPORATIVE/EXHAUST EMISSION
CONTROL
SYSTEM
18-6
AGILITY 125
EXHAUST MUFFLER
REMOVAL
Remove the two exhaust muffler joint lock
nuts and two exhaust muffler lock bolts.
Remove the exhaust muffler.
INSPECTION
1. Inspect the exhaust muffler and joint for
damage or crack. Replace if necessary.
2. Inspect the exhaust muffler joint packing
collar for deformation or damage. Replace
if necessary.
INSTALLATION
1. Install the exhaust muffler in the reverse
order of removal.
Exhaust Muffler Joint Lock Nut
•
The temperature of exhaust muffler is
very high. Be careful to avoid burns
during working.
*
Lock Bolts
Catalytic Converter
Exhaust Muffler
•
A large amount of unburned mixture flowing
into the high-heat catalytic converter will
burn again and cause damage to the
converter due to overheat. Pay attention to
the following.
*
•
Use 92# or 95# nonleaded gasoline only.
(Leaded gasoline will cause catalytic
converter failure.)
•
During riding, do not turn the ignition switch
OFF to avoid a large amount of unburned
mixture flowing into the exhaust muffler.
•
Faulty ignition system or fuel system will
cause overheat and damage to the catalytic