Figure 4-2 Fiber port testing
PING Command
:
The IP address of the testing computer 1 is 192.168.100.10 and the 2 is
192.168.100.11.On the testing computer 1, run “cmd” in the WIN2000
operating system or “command” in the WIN98/95 operating system from
“Run” in the “Start” menu. Send “ping 192.168.100.11 –l 1000 –t”. (-1
means byte number of the sent data package; -t means continuously
sending data). On the testing computer 2, run “cmd” in the WIN2000
operating system or “command” in the WIN98/95 operating system from
“Run” in the “Start” menu. Send “ping 192.168.100.10 –l 1000 –t”. If
switches run normally, the testing computer 1 returns “Reply from
192.168.100.11
:
bytes=1000 time<10ms TTL=128” and the 2 returns
“Reply from 192.168.100.10
:
bytes=1000 time<10ms TTL=128”, and the
counted package loss rate is zero checked by the CTL+C command ten
minutes after running.