Notice for Safety Operation

 

The  product  performs  reliably  as  long  as  it  is  used  according  to  the  guidance.  Artificial 

damage or destruction of the device should be avoided. Before using the device, read this 

manual  carefully  for  personal  and  equipment  safety.  Please  keep  the  manual  for  further 

reference. Kyland is not liable to any personal or equipment damage caused by violation of 

this notice. 

  Do not place the device near water sources or damp areas. Keep the ambient relative 

humidity within the range from 5% to 95% (non-condensing). 

  Do not place the device in an environment with high magnetic field, strong shock, or high 

temperature. Keep the working and storage temperatures within the allowed range. 

  Install and place the device securely and firmly. 

  Please keep the device clean; if necessary, wipe it with a soft cotton cloth. 

  Do  not  place  any  irrelevant  materials  on  the  device  or  cables.  Ensure  adequate  heat 

dissipation and tidy cable layout without knots. 

  Wear antistatic gloves or take other protective measures when operating the device. 

  Avoid any exposed metal wires because they may be oxidized or electrified. 

  Install the device in accordance with related national and local regulations. 

  Before power-on, make sure the power supply is within the allowed range of the device. 

High voltage may damage the device. 

  Power connectors and other connectors should be firmly interconnected. 

  Do not plug in or out the power supply with wet hands. When the device is powered on, 

do not touch the device or any parts with wet hands. 

  Before operating a device connected to a power cable, remove all jewelry (such as rings, 

bracelets, watches, and necklaces) or any other metal objects, because they may cause 

electric shock or burns. 

  Do not operate the device or connect or disconnect cables during an electrical storm. 

  Use  compatible  connectors  and  cables.  If  you  are  not  sure,  contact  our  sales  or 

technical support personnel for confirmation. 

Summary of Contents for SICOM3448G-C-Port-HV-HV

Page 1: ...SICOM3448G Series Industrial Ethernet Switch Hardware Installation Manual Publication Date Jan 2017 Version V1 0 No...

Page 2: ...ated as possible This document is not guaranteed to be error free and we reserve the right to amend it without notice to users All rights reserved No part of this documentation may be excerpted reprod...

Page 3: ...ls on the device or cables Ensure adequate heat dissipation and tidy cable layout without knots Wear antistatic gloves or take other protective measures when operating the device Avoid any exposed met...

Page 4: ...purchase parts from other channels Dispose of the device in accordance with relevant national provisions preventing environmental pollution In the following cases please immediately shut down your pow...

Page 5: ...00 1000Base T X Ethernet Port 8 4 2 1000Base X 10 100 1000Base T X SFP Slot 9 4 3 1000Base X 10 100 1000Base T X Combo port 11 4 4 10GBase X SFP port 12 4 5 Console Port 12 4 6 Grounding 13 4 7 Power...

Page 6: ...ation Models SICOM3448G Port HV HV SICOM3448G C Port HV HV Code definition Code option C Indicating three anti coating Ports port 4X8G16GE 4X8G24GX16GE 4X20G28GE Note 4X8G24GX16GE four 10GBase X SFP E...

Page 7: ...ean and ensure switch performance 2 1 Front Panel Figure 1 Front Panel Table 2 Description of Front Panel No Identifier Description 1 Alarm Alarm LED 2 Run Running LED 3 PWR2 Power 2 LED 4 PWR1 Power...

Page 8: ...nel identification Description 1 GE 1 16 Sixteen 10 100 1000Base T X Ethernet ports 2 GE GX 17 24 Eight 1000Base X 10 100 1000Base T X Combo ports 3 XG 1 4 Four 10 Gigabit SFP ports 4 FAULT Alarm term...

Page 9: ...mension Drawing unit mm Caution As part of the heat dissipation system the switch housing becomes hot during operation Please use caution when coming in contact and avoid covering the switch housing w...

Page 10: ...e 5 4 No direct sunlight distant from heat source and areas with strong electromagnetic interference 5 Devices are to be installed in an authority certified enclosure and accessible only by the use of...

Page 11: ...spectively Figure 5 Installing Mounting Brackets Mounting Step 1 Select the mounting position for the device and guarantee adequate space and heat dissipation for it dimensions 440mm 88mm 325mm Step 2...

Page 12: ...Dismounting Step 1 Remove the four screws and supporting captive nuts securing the mounting brackets to the rack posts Step 2 Remove the switch from the rack posts Then unscrew the mounting brackets t...

Page 13: ...h or cross over cable Pin Definition Figure 7 RJ45 Port Table 4 Pin Definitions of 10 100 1000Base T X RJ45 Port Pin MDI X MDI 1 Transmit Receive Data TRD1 Transmit Receive Data TRD0 2 Transmit Receiv...

Page 14: ...ransmission only after inserting an SFP optical module into the slot and connecting cable properly The following table lists the Gigabit SFP optical modules optional supported by the series switches T...

Page 15: ...ection of Gigabit SFP Optical Module How to Connect the SFP Optical Module Insert the SFP optical module into the SFP slot in the switch and then plug the optical fiber into the TX port and RX port of...

Page 16: ...burned 4 3 1000Base X 10 100 1000Base T X Combo port As shown in following table the 1000Base X 10 100 1000Base T X Combo port consists of one 1000Base X SFP port GX and one 10 100 1000Base T X Ether...

Page 17: ...10GBase X SFP port are same as the gigabit SFP slot user can refer to 4 2 4 5 Console Port There is a Console port on the front panel of the switch as shown in Figure 12 Connect the 9 pin serial port...

Page 18: ...tects the device from lightning and interference Therefore you must ground the device properly You need to ground the device before it is powered on and disconnect the grounding cable after the device...

Page 19: ...proving network reliability Note 0 75mm2 Cross sectional area of the power cable 2 5mm2 Grounding resistance 5 5 pin 5 08mm spacing plug in terminal block Figure 14 5 Pin 5 08mm Spacing Plug in Termin...

Page 20: ...ut the device may be damaged Warning Do not touch any exposed conducting wire terminal or component with a voltage warning sign because it may cause personal injury Do not remove any part or plug in o...

Page 21: ...ge withstand 2KV Note Pin 1 and pin 2 are normally open contacts pin 2 and pin 3 are normally closed contacts When the switch works properly pin 1 and pin 2 are closed pin 2 and pin 3 are open when an...

Page 22: ...rm occurs Off No alarm occurs port connection status LEDs Link ACT 1 48 On Effective port connection Blinking Ongoing network activities Off No effective port connection Port Connection status LEDs Li...

Page 23: ...1000Base T X SFP slot speed LED Gigabit SFP optical module On 1000M working state 1000Base TX Off 100M working state 100Base FX or no connection 1000Base X 10 100 1000Base T X SFP slot connection sta...

Page 24: ...ch to the 9 pin serial port of a PC with the delivered DB9 RJ45 console cable Step 2 Open the Hyper Terminal in the Windows OS On the desktop click Start All Programs Accessories Communications Hyper...

Page 25: ...munication port in use right click My Computer and click Property Hardware Device Manager Port to view the communication port Step 5 Set port parameters Bits per second 115200 Data bits 8 Parity None...

Page 26: ...oad default Restore the factory default settings Management view SWITCH config terminal Enter the configuration view 6 2 Access through Telnet Step 1 Connect the network port of a PC to the Ethernet p...

Page 27: ...the browser The user login interface is displayed You can log in to the Web UI by default user name admin and password 123 Note IE8 0 or a later version is recommended For details about how to access...

Page 28: ...rminal block Rated Power Consumption Rated Power Consumption 70W MAX Physical Characteristics Housing Metal fanless Installation 19 inch 2U rack mounting Dimensions W H D 440mm 88mm 325mm excluding th...

Page 29: ...ice Hotline 010 88796676 FAX 010 88796678 Website http www kyland com cn Email services kyland com cn For more information about KYLAND products please visit our website http www kyland com cn http ww...