background image

                                                SICOM3010G  User’s Manual-v1.0 

28 

 

Management View 

SWITCH#show version 

Show version of switch 

Management View 

SWITCH#reboot 

Reboot 

Management View 

SWITCH#load default 

Restore default configuration (except 

for IP address) 

Management View 

SWITCH#config terminal 

Enter configuration view 

8.2  Connected through Ethernet Cable 

1. Connect any RJ45 port of the switch with the Ethernet port of a personal 

computer with a RJ45 cable. 

2. Open Run window from the start menu, then input “ ‘IP address’”. 

The default IP address is 

192.168.0.2

.

 

 

Figure 30 Enter Telnet 

3. Click “OK” to enter the Telnet configuration interface. Type in a CLI 

command from Table 9. 

8.3  Web Access 

1. Connect the Ethernet port on the PC to any RJ45 port on the switch.

   

2. Input the IP address of the current switch in web browser, the default IP is 

Summary of Contents for SICOM3010G

Page 1: ...al Ethernet Switch Hardware Installation Manual Kyland Technology Co LTD Publication Date Oct 2011 Version V1 0 Customer Service Hotline 8610 88796676 FAX 8610 88796678 Website http www kyland cn E mail support kyland biz ...

Page 2: ...curate and as updated as possible This document is not guaranteed to be error free and we reserve the right to amend it without notice to users Copyright 2011 KYLAND Technology CO LTD All rights reserved No part of this documentation may be excerpted reproduced translated annotated or duplicated in any form or by any means without the prior written permission of KYLAND Corporation ...

Page 3: ...not tie or wrap the cable which may cause a fire risk Power connectors and other equipment connectors should be firmly interconnected and checked frequently Do not repair the equipment by yourself unless it is clearly specified in the manual Please keep the equipment clean if necessary wipe the equipment with soft cotton cloth In the following cases please immediately shut down your power supply a...

Page 4: ...ase X 10 100 1000Base T X SFP Port 14 5 2 1 Gigabit SFP Optical Module 14 5 2 2 Gigabit SFP Electrical Module 16 5 3 1000Base X 10 100 1000Base T X Combo Port 17 5 4 Console Interface 18 5 5 Power 19 5 6 Grounding 20 5 7 Relay Contact 22 6 LED Indicators 23 7 Reset Button 25 8 Management Access 25 8 1 Connected through Console Port 25 8 2 Connected through Ethernet Cable 28 8 3 Web Access 28 9 Pro...

Page 5: ... Ethernet switch that can be applied extensively in wind power distribution network automation subway PIS AFC power SACDA wastewater treatment highway metallurgy hydroelectric power photovoltaic power railway CBTC factory automation intelligent transportation and many other industries SICOM3010G has a Mini USB Console port and supports Web Telnet and Console network management supports VCT Virtual...

Page 6: ...e and Interface 3 1 Front Panel SICOM3010G 2GX GE 6GE Figure 1 Front Panel 1 Table 1 SICOM3010G 2GX GE 6GE Front Panel Number Diagram Label Description 1 PWR1 Power 1 LED 2 PWR2 Power 2 LED 3 Run Running LED 4 Ring Ring LED 5 Reset Reset button ...

Page 7: ...7 GX8 GE8 1000Base X 10 100 1000Base T X Combo port 9 GE1 GE6 10 100 1000Base T X RJ45 port 10 RJ45 port Speed LED 11 RJ45 port Link ACT LED SICOM3010G 2GX GE 2GX 6GE Figure 2 Front Panel 2 Table 2 SICOM3010G 2GX GE 2GX 6GE Front Panel Number Diagram Label Description 1 PWR1 Power 1 LED ...

Page 8: ...ED 5 Reset Reset button 6 Console Console interface 7 Alarm Alarm LED 8 GX9 GX10 1000Base X 10 100 1000Base T X SFP port 9 GX7 GE7 GX8 GE8 1000Base X 10 100 1000Base T X Combo port 10 GE1 GE6 10 100 1000Base T X RJ45 port 11 RJ45 port Speed LED 12 RJ45 port Link ACT LED 3 2 Top Panel ...

Page 9: ...OM3010G Top Panel Number Description 1 Power supply terminal block 2 Grounding Screw 3 Relay contact 4 Mounting 4 1 Dimension Drawing Dimension Drawing for DIN Rail Mounting Unit mm Figure 4 DIN Rail Mounting Dimension Dimension Drawing for Panel Mounting Unit mm ...

Page 10: ...osition for SICOM3010G and ensure that there is adequate space Step 2 Insert the top of the DIN Rail into the slot of the DIN Rail connecting seat in the rear panel of SICOM3010G as shown below move the switch in the direction of arrow 2 to put the whole Din Rail into the seat check whether SICOM3010G is firmly mounted on the DIN Rail as shown below Figure 6 DIN Rail Mounting ...

Page 11: ... of arrow 3 Figure 7 Dismounting SICOM3010G Panel Mounting The specific steps are as follows Step 1 Select the mounting position for SICOM3010G on the wall or in cabinet ensure that there is adequate space for the switch Step 2 Drill 4 holes on the selected position according to the panel mounting dimension drawing use a cross screwdriver to screw 4 cross slot screws M3 10 into holes Don t tighten...

Page 12: ...to the wall or cabinet Figure 8 Panel Mounting Remove SICOM3010G from wall or cabinet The specific steps are as follows Step 1 Use a screwdriver to loosen 4 screws move the switch up to let screws into 4 holes with the diameter of 6 5mm Ф6 5 Step 2 Unscrew the screws from wall or cabinet remove the switch from wall or cabinet Figure 9 Dismounting ...

Page 13: ...5 port is shown in Figure 10 Figure 10 RJ45 Port Pin definition of 10 100 1000Base T X RJ45 port is shown in Table 4 Table 4 Pin Definition of 10 100 1000Base T X RJ45 Port Pin MDI MDI X 1 Transmit Receive Data TRD0 Transmit Receive Data TRD1 2 Transmit Receive Data TRD0 Transmit Receive Data TRD1 3 Transmit Receive Data TRD1 Transmit Receive Data TRD0 4 Transmit Receive Data TRD2 Transmit Receive...

Page 14: ...rity Wiring Sequence Figure 11 10 100 1000M Straight through Cable Wiring Figure 12 10 100 1000M Cross over Cable Wiring Note The correlation between the pin of RJ45 connector and the color of twisted pair is 1 orange and white 2 orange 3 green and white 4 blue 5 blue and white 6 green 7 brown and white 8 white ...

Page 15: ... as shown in Table 11 5 2 1 Gigabit SFP Optical Module Figure 13 shows an example of a Gigabit SFP optical module Figure 13 Gigabit SFP Optical Module Gigabit SFP optical module is equipped with LC connector and each port consists of TX transmit port and RX receive port as shown in Figure 14 Connect the TX transmit port of switch A to the RX receive port of switch B and the RX receive port of swit...

Page 16: ...her switch to communicate 2 Check the corresponding port Link ACT indicator in the front panel Indicator flashing means link connectivity Indicator off means no link connectivity and it may be because of the incorrect link between RX port and TX port in SFP optical modules Try to swapping connectors in any one end of optical fiber The use of SFP optical module While wiring first insert the SFP opt...

Page 17: ...le Figure 16 shows an example of a Gigabit SFP electrical module Figure 16 Gigabit SFP Electrical Module The use of SFP electrical module While wiring first insert the SFP electrical module into the SFP slot in the switch and then plug the twisted pair into the SFP electrical module See Figure 17 ...

Page 18: ...X Combo port consists of one 1000 Base X port GX7 and one 10 100 1000Base T X Ethernet port GE7 and only one of the two ports can be used at one time Besides the 1000 Base X port has priority over 10 100 1000Base T X port Plug the optical fiber and the twisted pair into GX7 and GE7 respectively GX7 can communicate normally and the GE7 will be disabled automatically ...

Page 19: ...r to section 5 2 1 5 4 Console Interface Install the driver for Mini USB onto your PC The driver Mini USB driver exe is in the software download folder which is on the supplied CD Connect the USB port on the PC to the Console interface on the switch with cable equipped with Mini USB connector and USB connector at both ends Run Hyper Terminal software in WINDOWS operating system to connect to conso...

Page 20: ...umber is shown in Figure 20 Figure 20 USB Connector USB pin definition is shown in Table 6 Table 6 USB Pin Definition USB Pin Definition 1 VBUS 2 D 3 D 4 GND 5 5 Power According to the power input requirements use a 5 08mm spacing terminal block to connect power cable Note The cross section area of power cable is required to be greater than 0 75mm2 ...

Page 21: ...on Contact Number DC Wiring Definition AC Wiring Definition 1 PWR1 PWR1 L 2 PWR1 PWR1 N 3 Protection Ground Protection Ground 4 PWR2 PWR2 N 5 PWR2 PWR2 L Wiring and mounting Step 1 Take the power terminal block off the switch Step 2 Insert the power cable into the terminal block and connect the power cable Step 3 Put the terminal block back to the switch with the connected cable 5 6 Grounding Chas...

Page 22: ...the cable is reliably grounded The cross section area of chassis grounding cable should be more than 2 5mm2 The grounding resistance requirement 5Ω The grounding part in the 5 08mm power terminal block is called protection ground It is required to connect the chassis grounding part with the protection grounding part with supplied 18 AWG yellow green line to allow the switch to operate safely and p...

Page 23: ...cuit that leads to leakage electricity Figure 24 Disconnect 18 AWG Yellow Green Line Unit mm 5 7 Relay Contact The relay contact is used for alarm output When the switch works normally the normally open contact of the alarm relay is closed and the normally closed contact is open when the alarm occurs the normally open contact is open and the normally closed contact is closed The alarm is outputted...

Page 24: ...ts When the switch works normally the pin 1 and 2 are closed pin 2 and pin 3 are open when the alarm occurs the pin 1 and 2 are open pin 2 and 3 are closed Wiring and mounting Step 1 Take the alarm terminal block off the switch Step 2 Insert the cable for alarm output into the alarm terminal block according to the requirements and connect the cable Step 3 Put the alarm terminal block back to the s...

Page 25: ...Power 2 disconnects or operates abnormally Ring LED Ring ON Master DT Ring mode Root DRP mode Blinking Slave DT Ring mode B Root DRP mode OFF No ring mode 10 100 1000Base T X RJ45 port LEDs Each RJ45 port has two indicators a yellow LED and a green LED The yellow LED indicates port rate while the green LED indicates port connection state Speed Yellow ON 1000M working state OFF 10 100M working stat...

Page 26: ...down for more than 5 second to avoid restoring default configuration 8 Management Access Access the switch by one of the following three ways 8 1 Connected through Console Port 1 Install the driver for Mini USB onto your PC The driver Mini USB driver exe is in the software download folder which is on the supplied CD 2 Use the Console cable that is equipped with Mini USB connector at one end and US...

Page 27: ...SICOM3010G User s Manual v1 0 26 Figure 26 Hyper Terminal 4 Build a new connection named aa Figure 27 New Connection 5 Select COM port as the connection type ...

Page 28: ...ts 8 Parity None Stop bits 1 Flow control None Figure 29 Set COM Parameters 7 Click OK to enter the CLI interface and type in a CLI command from Table 9 Table 9 CLI Command View Command Description User View SWITCH enable Enter management view Management View SWITCH show interface Show the IP address of current switch ...

Page 29: ...ugh Ethernet Cable 1 Connect any RJ45 port of the switch with the Ethernet port of a personal computer with a RJ45 cable 2 Open Run window from the start menu then input telnet IP address The default IP address is 192 168 0 2 Figure 30 Enter Telnet 3 Click OK to enter the Telnet configuration interface Type in a CLI command from Table 9 8 3 Web Access 1 Connect the Ethernet port on the PC to any R...

Page 30: ...Configuration Information The specific configuration models of SICOM3010G are shown in Table 10 Table 10 SICOM3010G Configuration Model Interface Description Power SICOM3010G 2GX GE 6GE supports 2 1000Base X 10 100 1000Base T X Combo ports 6 10 100 1000Base T X RJ45 ports 12DC 24AC DCW dual redundant power SICOM3010G 2GX GE 2GX 6GE supports 2 1000Base X 10 100 1000Base T X Combo ports 21000Base X ...

Page 31: ... IGSFP M SX LC 850 0 55 1000Base X port multi mode LC connector wavelength is 850nm transmission distance is 550m IGSFP S LX LC 1310 10 1000Base X port single mode LC connector wavelength is 1310nm transmission distance is 10Km IGSFP S LH LC 1310 40 1000Base X port single mode LC connector wavelength is 1310nm transmission distance is 40Km IGSFP S ZX LC 1550 60 1000Base X port single mode LC conne...

Page 32: ...0G 2GX GE 6GE 10W MAX SICOM3010G 2GX GE 2GX 6GE 11 3W MAX Physical Characteristics Housing Metal fanless Installation DIN Rail or panel mounting Dimensions W H D 88mm 135mm 137mm Weight 1 25Kg Environment Limits Operating Temperature 40 85 Storage Temperature 40 85 Ambient Relative Humidity 5 95 non condensing MTBF 345000h Warranty 5 years For more information about KYLAND products please visit ou...

Reviews: